Inspection Status: Approved
Inspection History: MECHANICAL - ABOVE CEILING
| Date |
Description |
Inspector |
Results |
Comments |
| 04/28/2005 |
MECHANICAL - ABOVE CEILING |
|
Approved |
IVRS - Inspection :* |
| 03/30/2005 |
MECHANICAL - ABOVE CEILING |
|
Partial Approval |
IVRS - Inspection :* VENTS ON CONDENSATE DRAIN LINES MUST BE DOWNSTREAM OF THE TRAP. CONDENSATE DRAINS ON REFRIGERATION CASES OK TO COVER. |
| 03/24/2005 |
MECHANICAL - ABOVE CEILING |
|
Partial Approval |
IVRS - Inspection :* OK TEMP C OF O. OK TO COVER PHARMACY, TELEPHONE, BREAK RM AREA. OK TO COVER. |
| 03/23/2005 |
MECHANICAL - ABOVE CEILING |
|
Partial Approval |
IVRS - Inspection :* NEED SEISMIC ON SUPPLY /RETURN DIFFUSERS W/HARD DUCT FEEDS |
| 03/18/2005 |
MECHANICAL - ABOVE CEILING |
|
Partial Approval |
IVRS - Inspection :* DUCTS ABOVE CEILING GRID, NEED STRAPS OR # 9 WIRE SEISMIC WIRE, REGISTERS TO STRUCTURE. |
| 03/08/2005 |
MECHANICAL - ABOVE CEILING |
|
Not ready for Inspection |
IVRS - Inspection :* NOT READY |
| 02/23/2005 |
MECHANICAL - ABOVE CEILING |
|
Not ready for Inspection |
IVRS - Inspection :* NOT READY INSPECTED SUPPLY & EXHAUST IN RESTROOMS OK FOR SHEET ROCK |