Permit: T02CM03793
Permit Details
Apply Date:
08/12/2002
Applicant:
STICKLEY DESIGN GROUP
Description:
TI: RESIDENTIAL CARE
Architects:
- STICKLEY DESIGN GROUP
Contractors:
- CHESTNUT CONSTRUCTION CORPORATIO
Permit Reviews
Permit Number - T02CM03793
Permit Status: C of o
Permit Description: TI: RESIDENTIAL CARE
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
02/28/2003 | REVISION | 03/11/2003 | COMPLETED |
04/10/2003 | 3RD PARTY REVIEW-REVISION/OTHER | 04/14/2003 | COMPLETED |
04/14/2003 | REVISION | 04/15/2003 | COMPLETED |
06/16/2003 | REVISION | 06/19/2003 | COMPLETED |
06/18/2003 | REVISION | 06/18/2003 | COMPLETED |
06/18/2003 | REVISION | 06/18/2003 | COMPLETED |
08/12/2002 | SITE | 09/17/2002 | COMPLETED |
09/10/2002 | 3RD PARTY COMMERCIAL TI | 10/09/2002 | COMPLETED |
09/30/2002 | SITE | 10/01/2002 | COMPLETED |
10/03/2002 | RESUBMITTAL - SITE | 10/15/2002 | COMPLETED |
10/09/2002 | RESUBMITTAL | 10/15/2002 | COMPLETED |
12/04/2002 | REVISION | 12/11/2002 | COMPLETED |
12/31/2002 | REVISION | 01/06/2003 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T02CM03793
Permit Status: C of o
Permit Description: TI: RESIDENTIAL CARE
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
08/12/2002 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T02CM03793
Permit Description: TI: RESIDENTIAL CARE
Total Completed Inspections - 31
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/25/2002 | FRAMING | AMATHIES | Approved | IVRS - Inspection 0000*73 A-33A-22N & NORTH. |
10/30/2002 | FIRE SPKLR - FINAL | LTHOMAS | Approved | APPROVAL FOR FIRE SPRINKLER UNDERGROUND ONLY. |
10/30/2002 | FIRE SPKLR - UG PIPING FLUSH | LTHOMAS | Approved | |
10/30/2002 | FIRE SPKLR - UG, PIPING, HYDRO | LTHOMAS | Approved | |
11/01/2002 | FIRE - HYDRANTS | CSCHULTZ | Approved | |
11/20/2002 | SHEET ROCK NAILING | AMATHIES | Approved | IVRS - Inspection 0000* |
11/21/2002 | PLUMBING - ROUGH, SOIL | TRINIVJR | Approved | IVRS - Inspection 0000*1.) SOIL WATER TEST IS OK 2.) P.O.C. OF NEW BLDG. DRAINS TO EXSISTING BLDG. DRAINS IS OK. 2.) THIS INSPECTION IS FOR MENS & WOMENS RESTROOM #232,233 SECTION 5 AND RM #227 D.F. AND D.F. IN AD STORAGE RM #275. |
12/18/2002 | PLUMBING - FINAL | TRINIVJR | Approved | IVRS - Inspection 0000*1.) PLBG FINAL IS OK FOR SECTION (1) ONLY. 2.) SECTION ONE IS OK FOR TEMP C OF O. |
12/19/2002 | RIGHT OF WAY - FINAL | MOTERO | Approved | |
12/19/2002 | NPPO - FINAL | PGILBERT | Approved | |
12/19/2002 | SIGN - FINAL | DJOHNSTO | Approved | IVRS - Inspection 0000* TEMP ONLY |
12/19/2002 | LANDSCAPE - FINAL | PGILBERT | Approved | Ok for Temp C of O for Section one. Plant Protection required fof landscape areas. Areas where plants are susceptible to injury by vechicular or pedrestrian traffic must be protected. ie curbs, bollards or low wall. LUC 3.7.2.3. |
12/19/2002 | ENGINEERING - FINAL | JBRUCKME | Approved | TEMPORARY C OF O APPROVED FOR SECTION #1 ONLY. PENDING INSTALLATION OF SIGNS FOR HANDICAPPED PARKING SPACES |
12/19/2002 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection 0000*OK TEMP C OF O SECTION #1 FOR FURNITURE AND ADMIN ONLY, NO PATIENT YET. |
12/20/2002 | FIRE - FINAL | JEGAN | Approved | APPROVED FOR TEMPORARY C OF O-AREA #1(OFFICES) ONLY. |
12/20/2002 | FIRE - ALARM FINAL | JEGAN | Approved | NEED PLANS/PERMIT FOR FIRE ALARM INSTALLATION. |
12/20/2002 | FIRE SPKLR - OH PIPING & HYDRO | JEGAN | Approved | IVRS - Inspection 0000* |
12/20/2002 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection 0000*SEC I OK TEMP C OF O |
12/20/2002 | BUILDING - FINAL | AMATHIES | Approved | IVRS - Inspection 0000*OK FOR TEMP C OF O. |
12/26/2002 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection 0000*1.) ADDITIONAL LAUNDRY PIPING INCORRIDOR 33A JANITOR RM 33 OK TO COVER MUST HAVE REVISED PLAN BEFORE FINAL. 2.) KITCHEN #278 SINK PIPING OK -OK TO COVER 3.) SECTIONAL GAS PIPING TERMINATES AT METER. SECTION FOR AREA ONE & AREA 2 CONNECTED. AREA ONE HAS BEEN FINALED AND IS READY FOR GAS. AREA 2 NOT READY. CAN GAS BE RELEASED TO APPROVED SECTION. |
12/30/2002 | MECHANICAL - ABOVE CEILING | CWILLIAM | Approved | IVRS - Inspection 0000*SECTION II. COMM RM $28 CONDENSATE PUMP?? WHERE DOES IT TERMINATE? |
12/30/2002 | PLUMBING - ABOVE CEILING | TRINIVJR | Approved | IVRS - Inspection 0000*SECTION #2 ABOVE CEILING IS OK. |
12/30/2002 | ELECTRIC - ABOVE CEILING | DSANTACR | Approved | IVRS - Inspection 0000*OK .U.G. FEEDER FROM PANEL EAST SIDE TO FRONT SITE LTG. 2.) PLUG UNUSED KO'S IN J-BOXES ABOVE CEILING ALSO EXIT & EM LIGHTS IN GRID NEED SIEZMIC. |
12/30/2002 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | IVRS - Inspection 0000*OK U.G. FEEDER FROM PANEL EAST SIDE TO FRONT SITE LTG. 2.) PLUG UNUSED K O'S IN J-BOX ES ABOVE CEILING ALSO EXIT & EM LIGHTS IN GRID NEED SIEZMIC. |
05/05/2003 | EXCAVATION/LAYOUT REBAR & ZON | AMATHIES | Approved | IVRS - Inspection 0000*EXPANSION JOINT @ 20 T0 24' ADD 1 PIECE OF REBAR. |
06/10/2003 | REINFORCED MASONRY PRE-GROUT | AMATHIES | Approved | IVRS - Inspection 0000* |
06/23/2003 | ELECTRIC - UNDERGROUND | RHOLLAND | Approved | IVRS - Inspection 0000* |
06/24/2003 | ROOF NAILING | AQUIROZ | Approved | |
06/24/2003 | EXT METAL CLIPS/EXT SHEATHING | AQUIROZ | Approved | |
06/24/2003 | STEM WALL/RETAINING WALL | AQUIROZ | Approved | |
06/27/2003 | PERMIT FINALED | AQUIROZ | Approved |