Permit: T02CM03793

Parcel: 11108313B


Addresses:

2502 N DODGE BL


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T02CM03793

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
06/24/2003 PLUMBING - INTERMEDIATE Approved IVRS - Inspection 0000*
03/28/2003 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*DF IN HALLWAY 182 TEST OK
ALSO TOP OUT IN 196 TEST OK.
03/27/2003 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*# 167, 166, 165A, OK TO COVER PLEASE PROVIDE APPROVED PLAN RED LINES ON JOB
03/04/2003 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*ROOM #254 TEST OK OK TO COVER SEC #5
ROOM #196 - 196A TEST ON UNDERGROUND SOIL OK
SUBJECT TO APPROVED REVISED DRAWINGS.
02/11/2003 PLUMBING - INTERMEDIATE Partial Approval GAS TEST ONLY. 2ND PHASE 60LBS TEST OK. ON GAS LINES
1.) PROVIDE LETTER FROM ARCHITECT ON ROOF JACK FLASHINGS FOR ROOF PENETRATIONS.
2.) PROVIDE EXPANSION TANK AT WATER HEATERS REPAIR VENTS & CAPS ON GAS FIXTURES.
3.) WILL NEED TO TALK WITH STEVE LONG. TO RELEASE GAS ON 2ND PHASE WILL APPROVAL FROM OTHER TRADES ON COMPLETION OF WORK.
02/10/2003 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*
02/04/2003 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*LOBBY HC WASHROOM #228 & 224 OK. NEED PLAN ON DRINKING FOUNTAIN. AREA #5. ROOM 223 & 233. #1 CO MISSING ON WC ALSO SEC PLUMBING NOT FOR INSULATION ON HOT WATER P-1 #5.
01/30/2003 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*
01/28/2003 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*HALLWAY #5 SOUTH & 4 SOUTH ROOMS ONLY OK TO COVER.
01/23/2003 PLUMBING - INTERMEDIATE Partial Approval SOUTH HALL PHASE 4. NOT READY PROVIDE MID STORY ANCHORS ON WATER PIPING FOR SHOWERS
HALLWAY #5 CENTER OK TO COVER TALK WITH MIKE.
01/17/2003 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*SEE #3 SOUTH HALL 5 NORTH HALL TEST OK ON COPPER IN WALLS PLUMBER TO PROVIDE CLEVIS HANGERS ON 3" WATER SERVICE/CHECK SPEC FOR INSULATION FOR WATER LINE.
01/16/2003 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*PLEASE CALL AGAIN.
01/02/2003 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*
12/26/2002 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*1.) ADDITIONAL LAUNDRY PIPING INCORRIDOR 33A JANITOR RM 33 OK TO COVER MUST HAVE REVISED PLAN BEFORE FINAL.
2.) KITCHEN #278 SINK PIPING OK -OK TO COVER
3.) SECTIONAL GAS PIPING TERMINATES AT METER. SECTION FOR AREA ONE & AREA 2 CONNECTED. AREA ONE HAS BEEN FINALED AND IS READY FOR GAS. AREA 2 NOT READY. CAN GAS BE RELEASED TO APPROVED SECTION.
11/05/2002 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*1.) COPPER WATER PIPING IN AREA #2 COMPLETE PIPING OK
PRESSURE TEST OK
2.) OK TO COVER STOI.
10/25/2002 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*1.) THIS INSPECTION IS FROM HALL #22,33,73 A TO THE NORTH ONLY. 2.) OVERHEAD WATER DISTRIBUTION IS OK 3.)OK FOR DRYWALL UPON BLDG. INSPECTORS APPROVAL.
10/20/2002 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*1.) ALL ABS WASTE & VENT SYSTEM HAS BEEN WATER TESTED 2.) PERM CAPS ON EXSISTING WASTE & VENT IS OK.