Permit: T01CM02349
Permit Details
Apply Date:
05/16/2001
Applicant:
JOHNS, DAVID F
Description:
INTERIOR REMODEL & STORAGE ADDITION
Architects:
- JOHNS, DAVID F
Contractors:
- SUNDANCE DESIGN AND CONSTRUCTION
Permit Reviews
Permit Number - T01CM02349
Permit Status: C of o
Permit Description: INTERIOR REMODEL & STORAGE ADDITION
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 05/16/2001 | 3RD PARTY COMMERCIAL TI | 07/03/2001 | COMPLETED |
| 05/18/2001 | SITE | 07/03/2001 | COMPLETED |
| 07/03/2001 | RESUBMITTAL | 07/05/2001 | COMPLETED |
| 07/03/2001 | RESUBMITTAL | 07/05/2001 | COMPLETED |
| 09/18/2001 | REVISION | 09/18/2001 | COMPLETED |
| 10/08/2001 | REVISION | 10/15/2001 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T01CM02349
Permit Status: C of o
Permit Description: INTERIOR REMODEL & STORAGE ADDITION
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 05/16/2001 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T01CM02349
Permit Description: INTERIOR REMODEL & STORAGE ADDITION
Total Completed Inspections - 32
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/11/2001 | EXCAVATION/LAYOUT REBAR & ZON | AMATHIES | Approved | IVRS - Inspection 0000*1.) MUST PROVIDE BACKFLOW PREVERTERS FOR CARBINATED WATER 009, AND ALL COFFEE MACHINES AND ICE MAKER 007, MUST CERT & TEST PRIOR TO FINAL INSPECTION. 2.) MUST USE DIRECTIONAL FITTINGS ON ALL CONTINUOUS WASTE FOR BOTH TRIPLE COMPT SINKS. SEE SECTION: 405.4 94 UPS. 3.) MUST PROVIDE C.O. FOR TRIPLE COMPT. SINKS @ DISHWASHING AREA. 4.) MUST RUN CONTINUOUS WASTE INDIRET TO FLOOR SINK FOR 3 COMPT SINK IN PEEP AREA. |
| 07/12/2001 | ELECTRIC - UFER | DSANTACR | Approved | IVRS - Inspection 0000* |
| 07/13/2001 | STEM WALL/RETAINING WALL | AMATHIES | Approved | IVRS - Inspection 0000* |
| 07/17/2001 | PLUMBING - ROUGH, SOIL | TRINIVJR | Approved | IVRS - Inspection 0000*1.) SOIL WATER TEST IS OK 2.) OK TO BACKFILL TRENCH 3.) ALL CORRECTION HAVE BEEN MADE. |
| 07/17/2001 | PLUMBING - ROUGH, SOIL | TRINIVJR | Approved | IVRS - Inspection 0000*1.) SOIL WATER TEST FOR ROUGH PLBG. @ SOUTH END OF BLDG IS OK 2.) OK TO BACKFILL TRENCH. 3.) P.O.C. OF NEW BLDG. DRAINS TO EXSISTING BLDG DRAINS ARE OK. 4.) NOTE: ROUGH PLBG ON NORTH SIDE FLOOR SINKS HORIZONTAL VENTS MUST BE 6" A.F.F. 5.) RE TEST SYSTEM ON NORTH SIDE DO NOT COVER. |
| 07/18/2001 | BUILDING PRE-SLAB | AMATHIES | Approved | IVRS - Inspection 0000* |
| 07/23/2001 | REINFORCED MASONRY PRE-GROUT | AMATHIES | Approved | |
| 07/27/2001 | FRAMING | AMATHIES | Approved | IVRS - Inspection 0000* |
| 07/27/2001 | ROOF NAILING | AMATHIES | Approved | IVRS - Inspection 0000* |
| 08/01/2001 | SHEET ROCK NAILING | AMATHIES | Approved | |
| 08/06/2001 | PLUMBING - ABOVE CEILING | TRINIVJR | Approved | IVRS - Inspection 0000*1.) ABOVE CEILING IS OK FOR GRID |
| 08/09/2001 | PLUMBING - GAS PRESSURE TEST | TRINIVJR | Approved | IVRS - Inspection 0000*1.) GAS PRESSURE TEST IS OK 2.) ALL CORRECTION HAVE BEEN MADE ON EXSISTING GAS LINE 3.) NOTE: WILL REQUIRE A REVISED AND APPROVED DRAWING ON RELOCATION OF WATER HTR AND GAS LINE & WATER LINES TO HTR PRIOR TO FINAL INSPECTION. |
| 08/17/2001 | PLUMBING - INTERMEDIATE | TRINIVJR | Approved | 1.) CLOSET RINGS HAVE BEEN INSTALLED. |
| 08/17/2001 | PLUMBING - INTERMEDIATE | TRINIVJR | Approved | PARTIAL PER TRINI . |
| 09/14/2001 | U VALUE FOR WINDOW | LHANLY | Approved | IVRS - Inspection 0000* |
| 09/17/2001 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection 0000*PROVIDE MIN. 1" CLEARANCE AROUND B VENT. ELBOW ON B VENT NOT HOOKED UP PROPERLY STILL NEED TO SEE DUCT SMOKE DETECTOR, DRAINS FROM WALK IN COOLERS & A/C UNIT. OK FOR CEILING TILES |
| 09/24/2001 | ELECTRIC - ABOVE CEILING | DSANTACR | Approved | IVRS - Inspection 0000* |
| 09/24/2001 | BUILDING ABOVE CEILING | AMATHIES | Approved | IVRS - Inspection 0000* |
| 10/12/2001 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection 0000*ALL CORRECTIONS HAVE BEEN AMDE. OK FOR C OF O. |
| 10/12/2001 | PLUMBING - FINAL | TRINIVJR | Approved | IVRS - Inspection 0000*1.) PLBG FINAL IS OK 2.) ALL CORRECTIONS HAVE BEEN MADE 3.) U.C.C. HAS BEEN PLACED @ METER 4.) OK FOR C OF O. |
| 10/12/2001 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection 0000* |
| 10/12/2001 | BUILDING - FINAL | AMATHIES | Approved | IVRS - Inspection 0000* |
| 10/15/2001 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | |
| 10/15/2001 | PERMIT FINALED | ENGINEER | Approved | |
| 10/15/2001 | RIGHT OF WAY - FINAL | ENGINEER | Approved | |
| 10/15/2001 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection 0000* |
| 10/15/2001 | ENGINEERING - FINAL | ENGINEER | Approved | |
| 10/15/2001 | ELECTRIC - CABLE DROP | DSANTACR | Approved | |
| 10/15/2001 | ELECTRIC - SERVICE RELOCATION | DSANTACR | Approved | |
| 10/15/2001 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | |
| 10/15/2001 | ELECTRIC - UNDERGROUND | DSANTACR | Approved | |
| 10/15/2001 | EXT METAL CLIPS/EXT SHEATHING | AMATHIES | Approved |