Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
Permit Number - T01CM02349
Inspection Description - MECHANICAL - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/12/2001 | MECHANICAL - FINAL | Approved | IVRS - Inspection 0000*ALL CORRECTIONS HAVE BEEN AMDE. OK FOR C OF O. | |
| 10/11/2001 | MECHANICAL - FINAL | Denied | IVRS - Inspection 0999*1.)BLOCK & CLAMP CONDENSATE DRAIN & GAS PIPE ON EXISTING AC UNIT. PAINT EXPOSED PVC W/LATEX PAINT. 2.) PROVIDE EXHAUST HOOD AT OUTLET ON NEW AC UNIT FOR HEATER FLUE GAS. VENT ON CONDENSATE DRAIN TRAP MUST BE DOWNSTREAM OF THE TRAP. 3.) EXHAUST VENT FROM WATER HEATER MUST BE 10' AWAY FROM WALL ON ROOF OR 2' ABOVE. 4.) HOOK UP VENT ON BAKERY OVEN. 5.) PROVIDE 1 CLEARANCE AROUND WATER HEATER VENT THRU CEILING. 6.) PROVIDE BLOCKING UNDER CONDENSORS FOR WALK IN COOLERS ANCHOR TO BLOCKING CORRECT & RECALL FOR FINAL. |