Permit: T00CM05561
Permit Details
Status:
Expired
Type:
COMMERCIAL OTHER
Address:
8727 E GOLF LINKS RD
Address NEW:
8727 E GOLF LINKS RD
Apply Date:
11/14/2000
Applicant:
GOLDEN STAR PROPERTIES ,
Description:
NEW:OFFICE BUILDING
Architects:
- BURTON, RICHARD ROGHAAR
Contractors:
- GOLDEN STAR PROPERTIES ,
Permit Reviews
Permit Number - T00CM05561
Permit Status: Expired
Permit Description: NEW:OFFICE BUILDING
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/05/2002 | RESUBMITTAL | 02/08/2002 | COMPLETED |
| 02/08/2002 | COMMERCIAL NEW | 03/08/2002 | COMPLETED |
| 02/15/2002 | RESUBMITTAL | 04/22/2002 | COMPLETED |
| 04/04/2002 | RESUBMITTAL | 04/22/2002 | COMPLETED |
| 04/22/2002 | RESUBMITTAL | 04/29/2002 | COMPLETED |
| 04/29/2002 | RESUBMITTAL | 05/01/2002 | COMPLETED |
| 07/10/2001 | SITE | 12/20/2001 | COMPLETED |
| 10/28/2003 | REVISION | 11/07/2003 | COMPLETED |
| 11/14/2000 | SITE | 07/10/2001 | COMPLETED |
| 12/10/2003 | REVISION | 12/11/2003 | COMPLETED |
| 12/11/2003 | REVISION | 12/11/2003 | COMPLETED |
| 12/20/2001 | RESUBMITTAL | 12/28/2001 | COMPLETED |
| 12/24/2002 | REVISION | 12/30/2002 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T00CM05561
Permit Status: Expired
Permit Description: NEW:OFFICE BUILDING
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 11/14/2000 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T00CM05561
Permite Description: NEW:OFFICE BUILDING
Total Outstanding Inspections - 3
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/31/2003 | BUILDING - FINAL | N/A | Partial Approval | IVRS - Inspection 0000* OK FOR TEMP C/O. EGRESS & STRUCUAL COMPLETE. ADD BACKING BEHIND GRAB BARS IN ADA RESTROOM. NEED FINALS FOR C/O INSP |
| 12/31/2003 | ENGINEERING - FINAL | N/A | Partial Approval | TEMPORARY C OF O APPROVED FINAL NOT TO BE GIVEN UNTIL THE FINAL GRADING INSPECTION #9190 FOR T00BU03370 IS COMPLETE AND APPROVED |
| 12/31/2003 | RIGHT OF WAY - FINAL | N/A | Partial Approval | TEMP ONLY |
Completed Inspections
Permit Status: Expired
Permit Number: T00CM05561
Permit Description: NEW:OFFICE BUILDING
Total Completed Inspections - 32
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/26/2002 | ELECTRIC - UFER | MCAPISTR | Approved | IVRS - Inspection 0000*1/0 BCU STD CONNECTION TO REBAR OK. |
| 06/26/2002 | EXCAVATION/LAYOUT REBAR & ZON | RSUBA | Approved | IVRS - Inspection 0000* |
| 07/02/2002 | STEM WALL/RETAINING WALL | RSUBA | Approved | IVRS - Inspection 0000*STEM WALL OK TO POUR. |
| 07/10/2002 | PLUMBING - ROUGH, SOIL | FMCCLURE | Approved | IVRS - Inspection 0000* DOMESTIC WATER LOOP INTO BLDG OK. |
| 07/23/2002 | BUILDING PRE-SLAB | RSUBA | Approved | IVRS - Inspection 0000* |
| 10/22/2002 | ELECTRIC - INTERMEDIATE | MCAPISTR | Approved | IVRS - Inspection 0245*PLEASE ADDRESS THE FOLLOWING: 1.) THE ELECTRICAL SERVICE HAS BEEN CHANGED FROM THAT SHOWN ON PLAN SHT. E2. PANELS WITH REQUIRE MAIN. 2.) THE WIRING METHOD USED ROMEX IS NOT MENTIONED ON THE SPEC. SHEET. 3.) LIGHTING HAS BEEN CHANGED FROM 2 X 4 FLOURESCENT FIXTURES TO RECESSED LUMINAIRIES 4.) GROUNDING OF THE SERVICE EQUIPMENT IS INCOMPLETE. 5.) BONDING OF THE SERVICE IN INCOMPLETE 6.) EXHAUST FANS IN BATHS ARE NOT WIRED. THE ENGINEER OF RECORD MUST APPROVE THE CHANGES AND REVISE HIS PLANS. PLANS W/REVISIONS MUST BE REVIEWED AND APPROVED BY CITY PLANS REVIEWER. THE ELECTRICAL PANEL SCHEDULES AND LOAD CALCULATIONS WILL REQUIRE UPDATING TO REFLECT ANY LOAD CHANGES. THANKS MAC. |
| 10/22/2002 | ROOF NAILING | RSUBA | Approved | IVRS - Inspection 0000* |
| 10/24/2002 | PLUMBING - INTERMEDIATE | FMCCLURE | Approved | IVRS - Inspection 0000* |
| 10/29/2002 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection 0000*OK FOR SHEET ROCK. |
| 10/29/2002 | FRAMING | RSUBA | Approved | IVRS - Inspection 0000* |
| 11/07/2002 | STUCCO MESH | RSUBA | Approved | IVRS - Inspection 0000*PROVIDE STUCCO CERT. |
| 01/30/2003 | SHEET ROCK NAILING | LHANLY | Approved | IVRS - Inspection 0000*FINISH NAILING UNDER WINDOWS WHERE INDICATED. |
| 09/12/2003 | ELECTRIC - TEMP POWER FOR TEST | MCAPISTR | Approved | |
| 09/17/2003 | ELECTRIC - TEMPORARY SERVICE | MCAPISTR | Approved | IVRS - Inspection 0000*/ 1) OK TO CLEAR, BOND REQUIRED BEFORE CLEARANCE WILL BE SENT TO TEP |
| 10/23/2003 | MECHANICAL - TEMP PWR FOR TEST | JMILITEL | Approved | IVRS - Inspection 0000* |
| 10/23/2003 | PLUMBING - GAS PRESS TEST FNL | JMILITEL | Approved | |
| 10/23/2003 | PLUMBING - GAS PRESS TEST FNL | RRICH | Approved | IVRS - Inspection 0000* |
| 10/23/2003 | BUILDING - TEMP POWER FOR TEST | LHANLY | Approved | IVRS - Inspection 0000* |
| 11/12/2003 | PLUMBING - GAS PRESSURE TEST | RRICH | Approved | IVRS - Inspection 0000* |
| 12/02/2003 | PLUMBING - YARD WTR LINE/TEST | RRICH | Approved | IVRS - Inspection 0000* |
| 12/05/2003 | OUTDOOR LIGHTING FINAL | JORTA | Approved | |
| 12/05/2003 | ELECTRIC - FINAL | JORTA | Approved | IVRS - Inspection 0000* |
| 12/05/2003 | ELECTRIC - CONSTRUCTION POWER | JORTA | Approved | |
| 12/05/2003 | ELECTRIC - UNDERGROUND | JORTA | Approved | |
| 12/08/2003 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection 0000*/ OK FOR C OF O. |
| 12/08/2003 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | |
| 12/12/2003 | PLUMBING - FINAL | RRICH | Approved | IVRS - Inspection 0000*/ ALL CORRECTIONS MADE. |
| 12/12/2003 | PLUMBING - PROGRESS | RRICH | Approved | |
| 12/12/2003 | PLUMBING - SEWER HCS CONNECT | RRICH | Approved | IVRS - Inspection 0000* |
| 12/12/2003 | PLUMBING - ABOVE CEILING | RRICH | Approved | |
| 12/31/2003 | FIRE - FINAL | JEGAN | Approved | IVRS - Inspection 0000*/ 1) OK C OF O |
| 01/14/2004 | LANDSCAPE - FINAL | JLINVILLE | Approved |