Permit Number: T00CM05561
Parcel: 136048300

Review Status: Completed

Review Details: COMMERCIAL NEW

Permit Number - T00CM05561
Review Name: COMMERCIAL NEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/08/2002 JIM EGAN FIRE REVIEW Approved
02/11/2002 MARK TITUS WATER REVIEW Approved
02/11/2002 JAMES TATE FLOODPLAIN REVIEW Denied
02/11/2002 PATRICIA GEHLEN ZONING REVIEW Denied
02/25/2002 RANDY SCHULER ELECTRICAL-COMMERCIAL REVIEW Approved
02/25/2002 HOLLY PEARCE PLUMBING-COMMERCIAL REVIEW Denied Plumbing 1. Provide the up stream M.H. Rim Elev. on the site plan. Show on the site plan where the sewer line comes out of the building and attaches to the HCS and the slope of same. If the FFE is not one foot higher than the up stream M.H. Rim provide a back water valve and access to same. Provide an access detail on the site plan. 2. Redo the water demand calculations. Water pressure can not exceed 80 PSI. Sec608.2 UPC 1994 Az. Code, inclued RP assem. in the water demand calc's.
02/25/2002 HOLLY PEARCE MECHANICAL-COMMERCIAL REVIEW Denied Mechanical 1. Provide access to the elevated roof ( sec4/6 on sheet 8) Per Sec 306.5 IMC 2000. 2. Complete OSA calculations Per Chapter 4 IMC 2000.
03/04/2002 RAUL PALMA BUILDING-COMMERCIAL REVIEW Denied
03/07/2002 GERRY KOZIOL WWM REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
03/08/2002 TAMI ACHONG OUT TO CUSTOMER Completed