Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Address:
2537 N ORACLE RD
Address NEW:
2537 N ORACLE RD
Apply Date:
05/01/2000
Applicant:
REICHERT BOB
Description:
REMODEL:CARPORTS TO ROOMS (3) T00VL00104
Contractors:
  • LONGHORN CONSTRUCTION

Permit Reviews

Permit Number - T00CM02201
Permit Status: C of o
Permit Description: REMODEL:CARPORTS TO ROOMS (3) T00VL00104
Start Date Submittal Complete Date Status  
05/09/2001 RESUBMITTAL 10/10/2001 STOPPED Review Details
07/24/2000 COMMERCIAL NEW 01/12/2001 COMPLETED Review Details
11/09/2000 SITE 05/09/2001 COMPLETED Review Details
11/09/2000 COMMERCIAL NEW 05/10/2001 STOPPED Review Details
12/23/2002 REVISION 12/23/2002 COMPLETED Review Details

Completed Inspections

Permit Status: C of o
Permit Number: T00CM02201
Permit Description: REMODEL:CARPORTS TO ROOMS (3) T00VL00104
Total Completed Inspections - 27
Date Description Inspector Results Comments
06/26/2001 PLUMBING - INTERMEDIATE JSTANLEY Approved IVRS - Inspection 0000*
07/25/2001 BUILDING PRE-SLAB EMONAHAN Approved IVRS - Inspection 0000$@ SIDE S SIDE UNIT.
08/27/2001 EXCAVATION/LAYOUT REBAR & ZON EMONAHAN Approved IVRS - Inspection 0000*
09/19/2001 ROOF NAILING EMONAHAN Approved
09/26/2001 FRAMING EMONAHAN Approved IVRS - Inspection 0000*
10/16/2001 STUCCO MESH EMONAHAN Approved IVRS - Inspection 0000*
11/02/2001 STEM WALL/RETAINING WALL EMONAHAN Approved IVRS - Inspection 0000*
12/07/2001 ELECTRIC - UNDERGROUND RHOLLAND Approved IVRS - Inspection 0000*
12/13/2001 PLUMBING - YARD WTR LINE/TEST JSTANLEY Approved IVRS - Inspection 0000*PA OK TO COVER CALL WHEN READY FOR 2ND PHASE.PA OK TO COVER 1ST PLACE CALL WHEN READY FOR 2ND COVER WATER LINE WITH CLEAN FILL FOR 12"
12/13/2001 ELECTRIC - TEMPORARY SERVICE RMAJUTA Approved OK TO CLEAR FOR CONST USE.1.) PANEL A TO BE LOCKED OUT BY CONTRACTOR 2.) PANEL B OK TO USE FOR CONSTRUCTION USE ONLY NO INSIDE WIRING TO BE ENERGIZED W/O INSPECTORS APPROVAL ONLY GFI'S BELOW PANEL.
12/22/2001 ELECTRIC - INTERMEDIATE RHOLLAND Approved IVRS - Inspection 0000*1.) PLEASE INSTALL BATH FANS FOR INSPECTION 2. JUNCTION BOX BELOW PANEL IN WORKING CLEARENCE VIOLATION 110-26. BOX NOT ASSCOCATED WITH ELECTICAL OK WALLS EXCEPT BATHROOM CEILING.
02/14/2002 SHEET ROCK NAILING AMATHIES Approved IVRS - Inspection 0000*GET REVISION STATING SUBSTITUTION OF DUCT WRAP IN LIEU OF DUCT CHASE FRAMING & DRY WALL.
10/29/2002 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection 0999*NO INSPECTION HAVE EVER BEEN CALLED FOR MECHANICAL REMOVE CEILING TILES KITCHEN REMOVE INSULATION LAYING ON TOP OF HOOD. REMOVE DUCT WRAP FROM GREASE DUCT EXPOSE WATER HEATER VENT. PROVIDE EQUIPMENT SCHEDULE NOT SHOWN ON PLANS. RAISE SEWER VENTS 2' ABOVE ANY AIR INTAKE INTO BLDG. PROVIDE A ROOF JACK ON WATER HEATER VENT PROVIDE AN OUTSIDE AIR VENT CONDENSATE CANNOT BE DRILLED IN THE SIDE OF A WASTE VENT WHERE IS EXHAUST & SUPPLY FOR LAUNDRY ROOM ? PROVIDE COMBUSTION AIR VENTS.
10/29/2002 LANDSCAPE - FINAL PGILBERT Approved Ok for temp C of O.

Bike rack is required per site plan.

Parking lot striping completion per site plan.

Complete decomposed granite per landscape plan; all bare ground is required to be covered with groundcover (ie decomposed granite).

Canopy tree are required in the Street landscape border (3 trees per plan).

Trash bin required.
10/29/2002 BUILDING - FINAL AMATHIES Approved IVRS - Inspection 0000*
10/30/2002 FIRE - FINAL LTHOMAS Approved PLANS AND PERMIT REQUIRED FOR INSTALLATION OF KITCHEN HOOD FIRE EXTINGUISHING SYSTEM.
12/30/2002 PLUMBING - FINAL JSTANLEY Approved IVRS - Inspection 0000*OK S.T.O.I LAS INSP. ON JOB PLEASE PROVIDE GAS CARDS.
12/30/2002 PLUMBING - PROGRESS JSTANLEY Approved
12/30/2002 PLUMBING - GAS PRESSURE TEST JSTANLEY Approved
12/30/2002 PLUMBING - ABOVE CEILING JSTANLEY Approved
12/30/2002 PLUMBING - ROUGH, SOIL JSTANLEY Approved
12/30/2002 ELECTRIC - FINAL RHOLLAND Approved IVRS - Inspection 0999*1.) WHERE IS DISCONNECTING MEANS FOR WATER HEATER? UNIT "A"
2.) PROTECT BULB ON CLOSETS LIGHT
3.) PANELS/DISCONNECTING MEANS FOR WATER HEATER TO HAVE WORKING SPACE & CLEARENCE PER 110-26 UNIT"B"
4.) FILL UNUSED OPENING IN PANEL "B"
5.) USE AN ANTIOXIDE COMPOUND WITH ALUMINUM CONDUCTORS PANEL "B"
6.) MISSING A COVER PLATE IN CLOSET.
7.) TIGHTEN LOOSE FITTINGS AT A/C UNITS.
8.) OUTDOOR LIGHT TO MEET TUCSON LIGHTING CODE SECTION #5.
9.) FINISH ITEM #1,3,4,6 &8 OF PREVIOUS INSPECTION.
01/17/2003 MECHANICAL - HOODS CWILLIAM Approved IVRS - Inspection 0000*
01/21/2003 MECHANICAL - ABOVE CEILING CWILLIAM Approved
01/21/2003 MECHANICAL - INTERMEDIATE CWILLIAM Approved
01/21/2003 ELECTRIC - ABOVE CEILING RMAJUTA Approved
01/30/2003 PERMIT FINALED AMATHIES Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW
C OF O_01-30-2003.TIF CERT OF OCC VIEW