Permit: T00CM02201

Parcel: 10709023A


Addresses:

2537 N ORACLE RD

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
01/21/2003 MECHANICAL - FINAL Approved IVRS - Inspection 0000*
01/17/2003 MECHANICAL - FINAL Partial Approval IVRS - Inspection 0000*PROVIDE DUCT EXTENSION ON TYPE I COOKING HOOD VENT BLOWER. DIRECT AWAY FROM ROOF TOP COMB. A/C UNIT ADJOINING BLOWER.
TERMINATE ABOVE TOP OF UNIT.
10/29/2002 MECHANICAL - FINAL Denied IVRS - Inspection 0999*NO INSPECTION HAVE EVER BEEN CALLED FOR MECHANICAL REMOVE CEILING TILES KITCHEN REMOVE INSULATION LAYING ON TOP OF HOOD. REMOVE DUCT WRAP FROM GREASE DUCT EXPOSE WATER HEATER VENT. PROVIDE EQUIPMENT SCHEDULE NOT SHOWN ON PLANS. RAISE SEWER VENTS 2' ABOVE ANY AIR INTAKE INTO BLDG. PROVIDE A ROOF JACK ON WATER HEATER VENT PROVIDE AN OUTSIDE AIR VENT CONDENSATE CANNOT BE DRILLED IN THE SIDE OF A WASTE VENT WHERE IS EXHAUST & SUPPLY FOR LAUNDRY ROOM ? PROVIDE COMBUSTION AIR VENTS.