Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/30/2002 | PLUMBING - ROUGH, SOIL | Approved | ||
| 11/02/2001 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection 0000*NOT READY PLEASE PROVIDE APPROVED REVISED PLAN FOR SITE WATER AND ITS BRANCHES PLEASE PROVIDE CLEAN FILL AROUND NEW PIPE NO BLACK PIPE FOR WATER PIPING. | |
| 07/25/2001 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection 0000*PLEASE WRAP ALL ABS IN CONCREAF. ROUGHT FOR GREASE TRAP ONLY OK BACK ORDER ON TRAP AT THIS TIME CONTRACTOR TO BOX OUT & CALL WHEN READY. | |
| 07/23/2001 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection 0000*LAUNDRY ROOM TEST ON UNDERGROUND SOIL KITCHEN AREA OK GREASE TRAP ROUGH AT LATE DATE. | |
| 07/16/2001 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection 0000*UNITS #6 #7 #8 TEST OK UNDERGROUND SOIL ONLY | |
| 07/10/2001 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection 0999*1.) GATE WAS LOCKED | |
| 07/09/2001 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection 0000*1.) SOIL WATER TEST FOR UNITS #1,2,3,4,5, ARE OK 2.) P.O.C. OF BLDG DRAIN TO BLDG. SEWER OK 3.) OK TO BACKFILL UNIT #1,2,3,4,5 ONLY 5.) KITCHEN DO NOT COVER A.) MUST USE DIRECTIONAL FITTING FOR TWO DAY C.O. B) HORIZONTAL VENT FOR FLOOR DRAIN P-8 MUST BE 6" ABOVE FLOOD RIM LEVEL C.) CAN NOT USE COMBO IN VERTICAL POSITION FOR P-4 TRAP ARM AND P01A MUST USE SAN TEE D.) TAP ARM FOR P-4 CAN ONLY HAVE 1-90 AND STUBB OUT MUST BE 2" WITH 2" TRAP E.) GREASE LINE EXCEEDS 135 ON HORONTAL MUST HAVE FULL SIZE C.O. F.) OK TO BACKFILL MANAGERS APT. ONLY. | |
| 06/26/2001 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection 0000*SEC 6 P-Z CALLS FOR 3" TO SHOWER? Z" HAS BEEN INSTALLED? UNIT #1 | |
| 06/18/2001 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection 0000*SITE SEWER PA. MAIN TRUNK ONLY 4". |
|
| 06/12/2001 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection 0000*PLEASE PROVIDE 1/4-1/8" PER FOOT ON 4" SITE SEWER.SEWER BACK PITCH IN A FEW AREAS.PLEASE CORRECT AND CALL AGAIN. | |
| 06/11/2001 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection 0000*1)PLEASE PROVIDE 10' WATER TEST.PLEASE NOTE WHEN BACKFILLING.PLEASE PROVIDE CLEAN FILLS.PLEASE INSTALL AS PER PLAN. |