Permit: T00CM01081
Permit Details
Apply Date:
03/06/2000
Applicant:
GRESHAM & BEACH ARCHITECTS
Description:
OPEN PARKING GARAGE:ORIGINAL EFFECTIVE 8-15-02
Contractors:
- TARGET GENERAL INC ,
Permit Reviews
Permit Number - T00CM01081
Permit Status: C of o
Permit Description: OPEN PARKING GARAGE:ORIGINAL EFFECTIVE 8-15-02
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/18/2002 | REVISION | 02/15/2002 | COMPLETED |
02/21/2001 | REVISION | 03/09/2001 | COMPLETED |
08/24/2000 | 3RD PARTY REVIEW-COMMERCIAL | 01/31/2001 | COMPLETED |
Completed Inspections
Permit Status: C of o
Permit Number: T00CM01081
Permit Description: OPEN PARKING GARAGE:ORIGINAL EFFECTIVE 8-15-02
Total Completed Inspections - 22
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/28/2000 | EXCAVATION/LAYOUT REBAR & ZON | DWITT | Approved | IVRS - Inspection 0000* (AISONS AT LINE E.5 (SHEAR WALL LOCATION) |
08/03/2001 | BUILDING - PROGRESS | DWITT | Approved | STOP WORK ON THE AIRPORT PARKING GARAGE.SECURE LOOSE MATERIAL AND DEBRIS. PROVIDE APPROVED SHOP DRAWINGS APPROVED BY WILDAN, FOR THE PRE-CAST CONCRETE ITEMS USED ON THE PARKING GARAGE. ALSO, PROVIDE WILDAN APPROVED SHOP DRAWINGS FOR THE METAL STAIRS. |
09/05/2001 | MECHANICAL - TEMP PWR FOR TEST | JMILITEL | Approved | IVRS - Inspection 0000* |
09/05/2001 | PLUMBING - TEMP POWER FOR TEST | RMYERS | Approved | 1.) OK FOR TEMP POWER. |
09/05/2001 | BUILDING - TEMP POWER FOR TEST | LHANLY | Approved | IVRS - Inspection 0999*WE NEED UL & POST REPAIR DATA PER DAVE MANN. |
09/07/2001 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | ROOF DRAINS COLUMLINE "F" 2-6. 1.) 4" N/H TO 6" N/H TO 8" N/H OK 2.) WATER TEST TO FIRST FLOOR OK 3.) TIE IN TO STORMDRAIN OK 4.) OK TO COVER THIS AREA. |
09/20/2001 | PLUMBING - FINAL | RMYERS | Approved | 1.) RPBP CERIFICATION ON FILE WITH TUCSON WATER 2.) THIS FINAL IS FOR PARKING STRUCTURE ONLY THERE MAYBE SOME REQUIRED INSPECTIONS DOCUMENTED UNDER T00CM01081 AND VICE VERSA 3.) PLUMBING FINAL OK 4.) OK FOR C OF O PENDING ANY OTHER INSPECTION. |
09/20/2001 | PLUMBING - INTERMEDIATE | RMYERS | Approved | |
09/21/2001 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection 0000* |
09/25/2001 | FRAMING | LHANLY | Approved | IVRS - Inspection 0000* |
09/25/2001 | BUILDING PRE-SLAB | LHANLY | Approved | IVRS - Inspection 0000* |
09/28/2001 | BUILDING - FINAL | LHANLY | Approved | IVRS - Inspection 0000*PHASE 1 STRUCTURAL OK 1.) YOU MAY NOT HANG SIGN FROM ELECTRIC CONDUIT, WATER PIPES,STAND PIPES ORDAIN PIPES. FASTEN SIGNS WITH HANGERS TO UNDERSIDE OF DECKS. 2.) I STILL NEED ELECTRIC APPROVAL & ELEVATOR CERTIFICATION. |
10/04/2001 | ELECTRIC - FINAL | JORTA | Approved | OK FOR TEMP C/O |
10/04/2001 | ELECTRIC - TEMP POWER FOR TEST | JORTA | Approved | PHASE I TEMP C OF O. ELECTRICAL LAST INSPECTOR TO SIGN OFF PER STEVE LONG APPROVED FOR TEMP C OF O MUST SEE MR. DAVE MANN DSD ADMIN. |
10/04/2001 | ELECTRIC - INTERMEDIATE | JORTA | Approved | IVRS - Inspection 0000*EAST 1/3 OF INTERMEDIATE IN SLAB OF UPPER FLOOR DECKING. |
11/30/2001 | STEM WALL/RETAINING WALL | LHANLY | Approved | IVRS - Inspection 0000*PREFAB BEGUN @F1 |
12/20/2001 | ELECTRIC - UNDERGROUND | JORTA | Approved | IVRS - Inspection 0000* |
07/18/2002 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | |
08/09/2002 | RIGHT OF WAY - FINAL | LLOPEZ | Approved | |
08/09/2002 | ELECTRIC - RECONNECT | JORTA | Approved | |
08/15/2002 | PERMIT FINALED | LHANLY | Approved | |
08/15/2002 | ENGINEERING - FINAL | DROBERTS | Approved |