Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING PRE-SLAB
Permit Number - T00CM01081
Inspection Description - BUILDING PRE-SLAB
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/21/2002 | BUILDING PRE-SLAB | Approved | IVRS - Inspection 0000* | |
| 03/13/2002 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000* | |
| 03/07/2002 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000*2ND LEVEL. 1.) LIFT BOLLARD MATS 1/2" MIN OFF DECK @ WEST STAIRWELL 2.) LIFT CARD REBAR 1/2" MIN OFF DECK @ EAST STAIRWELL 3RD LEVEL OK 2ND-3RD TRANSITION OK 1ST - 2ND LEVEL RAMP MAINTAIN CLEARANCE OF #6 CORD BARS ALONG WEST WALL 2" BETWEEN BARS.) | |
| 03/01/2002 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000*PARTIAL LEVEL 1-KL/1-15 PLACED WITHOUT INSPECTION/JK 8-15 PLACED WITHOUT INSPECTION? JK/1-8 OK TO POUR. | |
| 02/26/2002 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000*PARTIAL LEVEL 1 HJ8-15 OK; JL/1-8 FINISH REMOVING DEBRIS AND ADDING BULK ALSO REPLACE DRAIN FIXTURE. EJ/1-2 TURN ADOBES FOR 2 1/2 CLEANRANCE EARTH ESPECIALLY AROUND STAIR FINISH REMOVING LOOSE FILL ALONG TURN. | |
| 02/19/2002 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000*NE STAIR @ 3RD LEVEL CONCRETE POURED OVER CORD BARS WITHOUT PROPER SEPARATION OF #6 BARS 1" REQUIRED OVER BEAMS NOT #4. | |
| 02/12/2002 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000* | |
| 02/12/2002 | BUILDING PRE-SLAB | Not ready for Inspection | IVRS - Inspection 0000* | |
| 02/07/2002 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000*PARTIAL 1.) 3RD LEVEL A.) G-G.5 CHIPOUT EXCESS CONCRETE ALONG EASTSIDE. MAINTAIN 2' SPACING ON CORD BAR. PULL UP MESH AH WEST SIDE. B.) U.5K-STRAIGHTEN CORD BAR ON NORTH END. PLACE MISSING CORD BARS BY COLUMN @ K6. MAINTAIN 1/2" OFF DECK FOR CORD BAR ALONG WEST SIDE. | |
| 02/06/2002 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000*PARTIAL 2ND LEVEL GG.5; H-H.5;J.5-K A FINISH CHIPPING OUT CONRETE AT NORTHEND OF U.S B.) FINISH PLACING CHAIRS IN J.5-K C.) LIFT CORD BAR AT K LINE 1/2" ABOVE DECK 3RD LEVEL F-F.5 A MAINTAIN 2" SPACE FOR CORD BARS AT NORTH END B.LIFT CROSS TIES 1/2: OFF DECK. | |
| 01/31/2002 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000*F.8, G-8,H8 LEVEL 2/F8,G8H8 LEVEL 3/EG LEVEL 1. | |
| 01/30/2002 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000* | |
| 01/28/2002 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000*4 AREA ON 3RD 4 AREAS ON 2ND LEVEL. 1.) CONCRETE POURED ON 2ND & 3RD LEVEL WITHOUT INSPECTION. APPROVAL THROUGH CONVERSATION WITH R NOWAK. 2.) WE HAVE A PROBLEM WIHT PLACEMENT OF OME CONC. ON 3RD LEVEL. IT WAS PLACED WITHOUT PROPER SAMPLING BY TERRACOM. | |
| 09/25/2001 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000* | |
| 06/14/2001 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000* | |
| 06/13/2001 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000* | |
| 06/12/2001 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000* | |
| 06/08/2001 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000*LINE B-C AT 8-15 LINE D-E AT 8-15 |
|
| 06/05/2001 | BUILDING PRE-SLAB | Not ready for Inspection | IVRS - Inspection 0000* |