Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Development Package
Address:
1101 N 4TH AV
Apply Date:
07/05/2016
Applicant:
Lisa Bowers
Description:
GRADING/SWPPP - CASA DE LOS NINOS

Permit Reviews

Permit Number - DP16-0111
Permit Status: Complete
Permit Description: GRADING/SWPPP - CASA DE LOS NINOS
Start Date Submittal Complete Date Status  
03/23/2018 REVISION - GRADING 07/10/2018 COMPLETED Review Details
07/05/2016 DEV PKG - OK TO SUBMIT 07/12/2016 COMPLETED Review Details
07/10/2018 REVISION - GRADING 07/11/2018 COMPLETED Review Details
07/11/2018 REVISION - GRADING 08/21/2018 COMPLETED Review Details
07/12/2016 GRADING 09/22/2016 COMPLETED Review Details
09/22/2016 GRADING 10/10/2016 COMPLETED Review Details
12/08/2017 REVISION - GRADING 12/20/2017 COMPLETED Review Details

Completed Inspections

Permit Status: Complete
Permit Number: DP16-0111
Permit Description: GRADING/SWPPP - CASA DE LOS NINOS
Total Completed Inspections - 9
Date Description Inspector Results Comments
01/09/2017 PDSD Engineering Division Pre-Construction SITE Passed {Activity date: 01/09/2017; Status: Approved; Inspector: MRUSSO; Comment: Entered by DROBERT5 - 1) SITE HAS BEEN CLEARED AND ROUGH GRADED
2) INSTALL SEDIMENT CONTROLS PER YOUR SWPPP
3) POSTA YOUR NOI ON SITE
4) INSTALL A CONCRETE WASH OUT
5) PERFORM STORM WATER SELF INSPECTIONS
6) SWEEP UP TRACKED SOIL, MAINTAIN SEDIMENT CONTROLS
7) CALL FOR INSPECTION FRO ANY SITE CONCERNS AND PRIOR TO COVERING UNDERGROUND SITE WORK}
03/29/2018 PDSD Site/Engineering Division - NPPO Passed {Activity date: 03/29/2018; Status: Approved; Inspector: MRUSSO; Comment: Entered by DROBERT5 - }
03/19/2019 SITE - Stormwater Setup and Controls Passed {Activity date: 03/19/2019; Status: Approved; Inspector: BBENEDON; Comment: Entered by CBELL1 - } ; {Activity date: 12/05/2018; Status: Not ready for Inspection; Inspector: BBENEDON; Comment: Entered by CBELL1 - Install controls as needed.} ; {Activity date: 03/29/2018; Status: Partial Approval; Inspector: MRUSSO; Comment: Entered by CBELL1 - } ; {Activity date: 03/17/2017; Status: Continued; Inspector: MRUSSO; Comment: Entered by DROBERT5 - 1) ADD SUPPLEMENTAL SEDIMENT CONTROLS AROUND THE TEMP STOCKPILE.
2) SWEEP UP TRACKED SOIL OFF ADJACENT ROADWAYS}
03/21/2019 PDSD Site/Engineering Division - Landscaping Passed {Activity date: 03/21/2019; Status: Approved; Inspector: BBENEDON; Comment: Entered by CBELL1 - } ; {Activity date: 03/19/2019; Status: Not ready for Inspection; Inspector: BBENEDON; Comment: Entered by CBELL1 - Provide tree wells at the trees per detail} ; {Activity date: 03/29/2018; Status: Partial Approval; Inspector: MRUSSO; Comment: Entered by DROBERT5 - COMPLETE LANDSCAPING PER THE APPROVED PLANS}
03/21/2019 ENGR Engineering Final Passed {Activity date: 03/21/2019; Status: Approved; Inspector: BBENEDON; Comment: Entered by CBELL1 - this is the final phase of this project on the north east site. The rest of the site was inspected and completed previously by other inspector} ; {Activity date: 03/19/2019; Status: Partial Approval; Inspector: BBENEDON; Comment: Entered by CBELL1 - ADA parking spaces for this phase in the north east corner of the site are In compliance} ; {Activity date: 03/29/2018; Status: Continued; Inspector: MRUSSO; Comment: Entered by DROBERT5 - 1) COMPLETE SITE/GRADING WORK PER YOUR APPROVED PLANS.
2) PROVIDE A CERT STATEMENT FROM THE ENG OF RECORD.
3) HC PARKING ALONG THE NORTH SIDE OF BLDG DOES NOT MEET THE NO GREATER THAN 2% SLOPE IN ANY DIRECTION REQUIREMENT.
}
03/21/2019 SITE - Stormwater Follow-up Passed {Activity date: 03/21/2019; Status: Approved; Inspector: BBENEDON; Comment: Entered by CBELL1 - } ; {Activity date: 03/19/2019; Status: Continued; Inspector: BBENEDON; Comment: Entered by CBELL1 - There are no issues at this time} ; {Activity date: 01/30/2019; Status: Continued; Inspector: BBENEDON; Comment: Entered by CBELL1 - There is minor track out onto fourth Avenue} ; {Activity date: 01/24/2019; Status: Continued; Inspector: BBENEDON; Comment: Entered by CBELL1 - No concerns at this time.} ; {Activity date: 03/29/2018; Status: Partial Approval; Inspector: MRUSSO; Comment: Entered by CBELL1 - } ; {Activity date: 12/05/2018; Status: Continued; Inspector: BBENEDON; Comment: Entered by CBELL1 - there are no issues at this time.} ; {Activity date: 09/26/2017; Status: Continued; Inspector: MRUSSO; Comment: Entered by DROBERT5 - 1) LOOKED AT 18" HDPE STORM PIPE ALONG EAST SIDE OF BLDG
2) ENSURE PROPER SLOPE, PIPE IS BEDDED TO SPRING LINE AND TRENCH IS COMPACTED
3) CALL FOR INSPECTION FOR PRIOR TO COVERING PIPE TRANSITIONS AND DRAINAGE STRUCTURES

PICTURES TAKEN
4) ENSURE YOU COMPLY WITH YOUR STORM WATER PERMIT AND PLAN.} ; {Activity date: 03/17/2017; Status: Continued; Inspector: MRUSSO; Comment: Entered by DROBERT5 - 1) ADD SUPPLEMENTAL SEDIMENT CONTROLS AROUND THE TEMP STOCKPILE.
2) SWEEP UP TRACKED SOIL OFF ADJACENT ROADWAYS}
03/21/2019 ENGR Grading Final Passed {Activity date: 03/21/2019; Status: Approved; Inspector: BBENEDON; Comment: Entered by CBELL1 - }
03/21/2019 SITE - Stormwater Final Inspection Passed {Activity date: 03/21/2019; Status: Approved; Inspector: BBENEDON; Comment: Entered by CBELL1 - } ; {Activity date: 03/29/2018; Status: Partial Approval; Inspector: MRUSSO; Comment: Entered by DROBERT5 - ENSURE YOU FILE A NOTICE OF TERMINATION WITH ADEQ}
03/21/2019 COT - ENGR - Signage Final Passed {Activity date: 03/21/2019; Status: Approved; Inspector: BBENEDON; Comment: Entered by CBELL1 - }

Documents

File Name Document Type  
DP16-0111 LETTER OF COMPLETION.PDF LETTER OF COMPLETION VIEW
001_COVER SHEET_1 OF 12.TIF DEVELOPMENT PACKAGE VIEW
002_NOTES SHEET / DRAINAGE STATEMENT_2 OF 12.TIF DEVELOPMENT PACKAGE VIEW
003_BOUNDARY_3 OF 12.TIF DEVELOPMENT PACKAGE VIEW
004_EXISTING CONDITIONS_4 OF 12.TIF DEVELOPMENT PACKAGE VIEW
005_EXISTING CONDITIONS_5 OF 12.TIF DEVELOPMENT PACKAGE VIEW
006_GRADING / DRAINAGE_ 6 OF 12.TIF DEVELOPMENT PACKAGE VIEW
007_GRADING / DRAINAGE_7 OF 12.TIF DEVELOPMENT PACKAGE VIEW
008_ADA / ANSI GRADING_8 OF 12.TIF DEVELOPMENT PACKAGE VIEW
009_DETAILS_9 OF 12.TIF DEVELOPMENT PACKAGE VIEW
010_SWMP COVER_10 OF 12.TIF DEVELOPMENT PACKAGE VIEW
011_SWMP DETAILS_11 OF 12.TIF DEVELOPMENT PACKAGE VIEW
012_SWMP_12 OF 12.TIF DEVELOPMENT PACKAGE VIEW
None DOCUMENTS VIEW