Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Inspections
Type:
Development Package
Address:
7655 S KOLB RD
Address NEW:
7655 S KOLB RD
Apply Date:
10/13/2023
Applicant:
Alan Lessenden
Description:
Restricted Access - Development Package for new TPD Annex facility. Site design including grading and drainage design, paving plan, and on-site utilities.

Permit Reviews

Permit Number - TD-DEV-1023-00423
Permit Status: Inspections
Permit Description: Restricted Access - Development Package for new TPD Annex facility. Site design including grading and drainage design, paving plan, and on-site utilities.
Start Date Submittal Complete Date Status  
09/16/2024 DEVELOPMENT PACKAGE NEW v.3 10/11/2024 APPROVED Review Details
05/31/2024 DEVELOPMENT PACKAGE NEW v.2 07/26/2024 REQUIRES RESUBMIT Review Details
10/16/2023 DEVELOPMENT PACKAGE NEW v.1 12/18/2023 REQUIRES RESUBMIT Review Details

Outstanding Activity Conditions

Permit Number - TD-DEV-1023-00423
Permit Status: Inspections
Permit Description: Restricted Access - Development Package for new TPD Annex facility. Site design including grading and drainage design, paving plan, and on-site utilities.
Total Outstanding Activity Conditions - 3
Date Name
10/02/2025 CRWHPLAN NEEDS TO BE CREATED PRIOR TO CLOSEOUT
10/11/2024 Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact.
10/11/2024 Dust Control/Air Quality Permit is Required. (Utilized with DP's & TP's)

Outstanding Inspections

Permit Status: Inspections
Permit Number: TD-DEV-1023-00423
Permite Description: Restricted Access - Development Package for new TPD Annex facility. Site design including grading and drainage design, paving plan, and on-site utilities.
Total Outstanding Inspections - 7
Last Inspection Date Description Inspector Results Comments
04/25/2025 ENGR - Drainage Structures N/A Partial Pass See checklist items.
Outlet Header at catch basin one ready to pour when weir length corrected to 5’.
09/10/2025 N/A Partial Pass Security wall from refuse enclosure to building and on North side of building: first 2 courses are laid, reinforcement, including bond beam, is correct; okay to grout.
09/19/2025 For trash and recycling enclosures N/A Partial Pass Trash enclosure slab and approach: reinforcement, sub grade, slope, and thickness are accurate to plans; Okay to pour slab and approach.
10/02/2025 N/A Partial Pass Footer for flagpole: dimensions are good, steel tube and lightning spike are per manufacturer’s specs. Okay to pour.
10/16/2025 N/A Partial Pass Mainline adjacent to trailer/refuse enclosure is good to backfill. Lateral line trenches along East basin are sized properly and ready for pvc.
12/09/2025 ENGR Paving N/A Partial Pass Day 1 of 2 for paving. First lift through drive lane is complete. Second lift and parking stalls will be done tomorrow.
12/19/2025 Consultation SITE N/A Partial Pass Items required before Engineering Final: Finish Landscaping and irrigation system, complete site fence, install drive-gate openers.

Completed Inspections

Permit Status: Inspections
Permit Number: TD-DEV-1023-00423
Permit Description: Restricted Access - Development Package for new TPD Annex facility. Site design including grading and drainage design, paving plan, and on-site utilities.
Total Completed Inspections - 4
Date Description Inspector Results Comments
01/27/2025 PDSD Engineering Division Pre-Construction SITE Passed Went over all paperwork (3rd party inspection) that will be required to be on site. Went over what will be required to be inspected and what civil does inspect.
01/27/2025 NPPO Pre-Construction Passed
03/20/2025 COT - ENGR - Stormwater Passed Stormwater initiall is good, track pad needs to be a little bigger.
03/24/2025 Passed