Permit: TC-RES-1024-05976
Permit Details
Status:
Issued
Type:
Residential Building - One or Two Family
Address:
766 W NEBRASKA ST
Address NEW:
766 W NEBRASKA ST
Apply Date:
10/15/2024
Applicant:
Leonor Ortega
Description:
Convert Garage into Guest Room ; REV_1
Permit Reviews
Permit Number - TC-RES-1024-05976
Permit Status: Issued
Permit Description: Convert Garage into Guest Room ; REV_1
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/24/2025 | RESIDENTIAL NEW DWELLING v.3 | 02/24/2025 | REQUIRES RESUBMIT |
| 08/26/2025 | RESIDENTIAL NEW DWELLING REVISION v.1 | 09/29/2025 | APPROVED |
| 10/15/2024 | RESIDENTIAL NEW DWELLING v.1 | 10/15/2024 | REQUIRES RESUBMIT |
| 06/03/2025 | RESIDENTIAL NEW DWELLING v.5 | 06/03/2025 | APPROVED |
| 10/17/2024 | RESIDENTIAL NEW DWELLING v.2 | 11/24/2024 | REQUIRES RESUBMIT |
| 04/17/2025 | RESIDENTIAL NEW DWELLING v.4 | 05/16/2025 | REQUIRES RESUBMIT |
| 06/03/2025 | RESTAMP - RESIDENTIAL v.1 | 06/09/2025 | APPROVED |
Conditions
Permit Number - TC-RES-1024-05976
Permit Status: Issued
Permit Description: Convert Garage into Guest Room ; REV_1
| Date | Description | Comments |
|---|---|---|
| 06/03/2025 | The Contractor you have added to your permit cannot be verified. Please contact staff to have the ROC number added to the account. | |
| 01/31/2025 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |
Outstanding Inspections
Permit Status: Issued
Permit Number: TC-RES-1024-05976
Permite Description: Convert Garage into Guest Room ; REV_1
Total Outstanding Inspections - 4
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/02/2025 | COT - RSBU - Excavation/Rebar/Zoning | N/A | Not Applicable | 9.2.2025 Not applicable. |
| 09/02/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Re-inspection required | 9.2.2025 Secure water and ABS pipes midway and add Boca plates, firefoam the top plates throughout, smoke alarms missing in bedroom and main room, secure electrical lines near panel, missing receptacle at kitchen counter, receptacles need to be made up in box, missing mechanical equipment. Missing anchor bolts every 48" OC & within 12" of edge on west bearing wall, shot pins required 6" from edge and 2x for greater than 12" and every 32" on center per plan. |
| 09/02/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Re-inspection required | 9.2.2025 Secure water and ABS pipes midway and add Boca plates, firefoam the top plates throughout, smoke alarms missing in bedroom and main room, secure electrical lines near panel, missing receptacle at kitchen counter, receptacles need to be made up in box, missing mechanical equipment. Missing anchor bolts every 48" OC & within 12" of edge on west bearing wall, shot pins required 6" from edge and 2x for greater than 12" and every 32" on center per plan. |
| 03/09/2026 | RSBU - Building Final | N/A | Re-inspection required | 3-9-26: paint exterior cleanout, all exterior receptacles require bubble covers and receptacles must be weather resistant, add R3 insulation to hose bib together with hot leg of water heater, missing hammer arrestors at refrigerator water line and at washer & dryer, arch-fault breaker are required for every habitable location, install a shackle at water heater breaker. STOPPED INSPECTION-ADDITIONAL ITEMS MY BE NOTED. |
Completed Inspections
Permit Status: Issued
Permit Number: TC-RES-1024-05976
Permit Description: Convert Garage into Guest Room ; REV_1
Total Completed Inspections - 8
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/18/2025 | COT - RSPL - Rough Soil | Passed | 6-18-25: plumbing underground verified per plans. Okay to backfill with shading materials. | |
| 09/02/2025 | COT - RSPL - Yard Water Line | Passed | 9.2.2025 Corrections made. |
|
| 11/20/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 11.20.2025 All corrections made to prior inspection. Added fire foam to top plate penetrations, braced register ducts, shower tested for leaks, lowered thermostat to 48", ensured receptacle spacing at kitchen counter top. Okay to proceed with construction. |
|
| 11/20/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 11.20.2025 All corrections made to prior inspection. Added fire foam to top plate penetrations, braced register ducts, shower tested for leaks, lowered thermostat to 48", ensured receptacle spacing at kitchen counter top. Okay to proceed with construction. |
|
| 04/16/2026 | COT - RSPL - Plumbing Final | Passed | 04/16/2026 Corrections made to prior inspection. |
|
| 04/16/2026 | COT - RSEL - Electrical Final | Passed | ||
| 04/16/2026 | COT - RSEL - Outdoor Lighting | Passed | ||
| 04/16/2026 | COT - RSME - Mechanical Final | Passed |