Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSPL - Yard Water Line
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/21/2025 | COT - RSPL - Yard Water Line | Re-inspection required | 7/21/25: No access to main water line (dog must be secured), Not ready for inspection (wiring incomplete, spacing non code compliance, NM cable must be properly secured 12" from box at all locations, Pex lines require support on vertical runs throughout, DWV must be secured midway in wall, seal all penetrations through top plate and vapor barrier, lath must be installed for intermediate inspection). STOPPED INSPECTION MORE ITEMS MAY BE ADDED, DWV under test. | |
| 09/02/2025 | COT - RSPL - Yard Water Line | Passed | 9.2.2025 Corrections made. |