Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-RES-1024-05976

Parcel: 137054440


Addresses:

766 W NEBRASKA ST

Inspection Status: Re-inspection required

Inspection History: RSBU - Building FinalĀ 

Date Description Inspector Results Comments
03/09/2026 RSBU - Building FinalĀ  Re-inspection required 3-9-26: paint exterior cleanout, all exterior receptacles require bubble covers and receptacles must be weather resistant, add R3 insulation to hose bib together with hot leg of water heater, missing hammer arrestors at refrigerator water line and at washer & dryer, arch-fault breaker are required for every habitable location, install a shackle at water heater breaker. STOPPED INSPECTION-ADDITIONAL ITEMS MY BE NOTED.