Inspection Status: Re-inspection required
Inspection History: RSBU - Building FinalĀ
| Date |
Description |
Inspector |
Results |
Comments |
| 03/09/2026 |
RSBU - Building FinalĀ |
|
Re-inspection required |
3-9-26: paint exterior cleanout, all exterior receptacles require bubble covers and receptacles must be weather resistant, add R3 insulation to hose bib together with hot leg of water heater, missing hammer arrestors at refrigerator water line and at washer & dryer, arch-fault breaker are required for every habitable location, install a shackle at water heater breaker. STOPPED INSPECTION-ADDITIONAL ITEMS MY BE NOTED. |