Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Stop Work Order
Type:
Residential Building - One or Two Family
Address:
145 N GRANDE AV
Address NEW:
145 N GRANDE AV
Apply Date:
09/25/2024
Applicant:
Jeffrey Brack
Description:
REV1: Changed wall framing Replace Patio Cover with a Storage and Laundry Room

Permit Reviews

Permit Number - TC-RES-0924-05572
Permit Status: Stop work order
Permit Description: REV1: Changed wall framing Replace Patio Cover with a Storage and Laundry Room
Start Date Submittal Complete Date Status  
02/26/2025 RESIDENTIAL NEW DWELLING v.3 03/12/2025 REQUIRES RESUBMIT Review Details
09/25/2024 RESIDENTIAL NEW DWELLING v.1 10/28/2024 REQUIRES RESUBMIT Review Details
04/17/2025 RESTAMP - RESIDENTIAL v.1 04/18/2025 APPROVED Review Details
12/02/2024 RESIDENTIAL NEW DWELLING v.2 12/02/2024 REQUIRES RESUBMIT Review Details
03/25/2026 RESIDENTIAL NEW DWELLING REVISION v.1 04/08/2026 APPROVED Review Details
04/17/2025 RESIDENTIAL NEW DWELLING v.4 04/17/2025 APPROVED Review Details

Conditions

Permit Number - TC-RES-0924-05572
Permit Status: Stop work order
Permit Description: REV1: Changed wall framing Replace Patio Cover with a Storage and Laundry Room
Date Description Comments
12/02/2024 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.

Outstanding Inspections

Permit Status: Stop Work Order
Permit Number: TC-RES-0924-05572
Permite Description: REV1: Changed wall framing Replace Patio Cover with a Storage and Laundry Room
Total Outstanding Inspections - 3
Last Inspection Date Description Inspector Results Comments
03/12/2026 COT - RSBU - Preslab N/A Re-inspection required 3/12/26:Revision required for changes made to framing members( plans call for 2x6 exterior walls), 2x solid blocking required at roof, exterior sheathing missing nailing throughout (6"/12" required), anchor bolts must be spaced no more than 6" o.c and shall be no more than 12" from edge and no less than 3.5" from edge (must be installed in middle third of sill plate). Weep screed shall be 2" above concrete landing at entry and landing shall be corrected.
07/21/2026 COT - RSEL - Outdoor Lighting N/A Re-inspection required 7/21/26:Stop Work Order

Construction of the back porch is being performed outside the approved scope of work and is not included in the approved plans.
07/21/2026 COT - RSBU - Excavation/Rebar/Zoning N/A Re-inspection required 7/21/26:Stop Work Order

Construction of the back porch is being performed outside the approved scope of work and is not included in the approved plans.

Completed Inspections

Permit Status: Stop Work Order
Permit Number: TC-RES-0924-05572
Permit Description: REV1: Changed wall framing Replace Patio Cover with a Storage and Laundry Room
Total Completed Inspections - 8
Date Description Inspector Results Comments
02/24/2026 COT - RSPL - Rough Soil Passed
03/12/2026 COT - RSBU - Roof Nailing Passed
05/07/2026 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 05/07/2026
Approved per plan, added bracing to air registers and foamed top plate penetrations.
07/07/2026 COT - RSEL - Electrical Final Passed
07/07/2026 COT - RSME - Mechanical Final Passed
07/07/2026 COT - RSPL - Plumbing Final Passed
07/07/2026 COT - RSBU - Preslab Passed 07/07/2026
Corrections made to prior inspection, footing was verified and revision submitted.
07/07/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 07/07/2026
Corrections made to prior inspection, footing was verified and revision submitted.

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW
CONS-TC-RES-0924-05572 REV 2_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-TC-RES-0924-05572 REV3_V4.PDF DOCUMENTS VIEW
DDO-25-23 DECISION.PDF SPECIAL APPLICATIONS VIEW
DDO-25-23 APPLICATION AND PLAN SET.PDF SPECIAL APPLICATIONS VIEW