Review Date Reviewer's Name Type of Review Description Status Comments
10/25/2024 Site Engineering NOT REQUIRED
10/07/2024 Site Landscape NOT REQUIRED
10/28/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
10/10/2024 Residential Building REQUIRES RESUBMIT TC-RES-0924-05572
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. The plans require sufficient detail for demonstrating an awareness of minimum building code compliance for passing all progress inspections.

Provide a response letter on separate file with the updated construction plan set.

SITE PLAN:

1. Show the location of the electrical service panel, R106.1.1.

PLANS:

1. Provide a complete roof framing plan with a ridge member sized with appropriate load carrying capacity. Show the ridge structural member as a beam with appropriate size when the roof pitch is less than 3” to 12”, R802.3. Or show all roof structural members with rafter ties (or ceiling joists) and collar ties (ridge straps) when the roof pitch is equal or greater than 3” to 12”, R802.3.
2. Show roof structural members with rafter ties (or ceiling joists) and collar ties (ridge straps) when the roof pitch is equal or greater than 3” to 12”, R802.3.
3. Show the rafters sized for supporting live and dead structural loads (Table R802.4.1(1)) or provide an engineer’s sealed plan set for manufactured trusses, R301.1.3.

SECTIONS - DETAILS:

1. Provide a wall section detail with (#4 rebar) reinforced 12” x 12” reinforced foundations for anchoring exterior framed (insulated) walls with pressure treated sills including ½” anchor bolts with 7” embedment, R403.1.6.
2. Show exterior wood siding, sheathing and wall framing with a 6” clearance above the ground (R317.1 item 5). The weep screed may extend with a minimum clearance 4” above grade or 2” above paved areas, R703.7.2.1.
3. Show rafter (truss) to wall connection using (H2.5) ties having a resistance to uplift of not less than 365 pounds, R802.11.1. (City of Tucson Amended).

PLUMBING PLANS:

1. Clarify the point of connection of the new water line to existing service pipes, P2903.7.

ELECTRICAL PLANS:

1. Designate the circuit number at the location of each light fixture, receptacle, appliance, and equipment disconnect switch, R106.1.1.

OUTDOOR LIGHTING CODE

1. Show full cutoff fixtures were located within 25 feet from the property line OLC 401.3.3.

If you have any questions, please contact:
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services
----------------------
10/28/2024 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Bobby Parsons
Zoning Section Review

PROJECT: TC-RES-0924-05572
145 N Grande Av Tucson, AZ 85745
Replace patio cover with a storage and laundry room (1st Review)

TRANSMITTAL DATE: 10/28/2024

This site is located in the R-2 zone (UDC 4.7.9). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10.

Comments: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed.

1. Comment: The site plan should be designed to include the information as noted on the sample site plan. Please see https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf for reference.
2. Comment: Please dimension the street center line to face of curb and then from face of curb to the property line for both West Franklin Street and North Grande Avenue. Please also dimension the rear alley.
3. Comment: Please include the legal description and owner’s name for this parcel on your site plan. If needed, please refer to the sample site plan listed above.
4. Comment: Please include the lot coverage calculations on your site plan. Make sure to draw, label, and dimension all vehicular use areas on your site plan. Per UDC 6.4.3.C.1, “Roofed areas, open on at least one side, which provide shelter to exterior areas such as balconies, entrances, stoops, and terraces, provided they are not used for utilities, maintenance, laundry, storage, or motor vehicle parking are excluded from lot coverage calculations.” If needed, please refer to the sample site plan listed above.
5. Comment: Please draw, label, and dimension the property lines as they were not included on your site plan.
6. Comment: A Design Development Option (DDO) review and approval will be required since the proposed addition will reduce the setback along West Franklin Avenue to 1 foot. It is acknowledged a DDO application has been included with your first submittal however please address these zoning comments and apply for the DDO on your next submittal. If needed, here is a link to the DDO application: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/planning-amp-zoning/ddo_for_setback_and_height_udc.pdf
7. Comment: Additional comments may be forthcoming based on responses to zoning comments and changes made to the plans.

If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov (520) 837-4977.
09/25/2024 PDSD Application Completeness Express REVIEW COMPLETED