Permit: TC-RES-0625-02830
Permit Details
Status:
Complete
Type:
Residential Building - One or Two Family
Address:
3101 E 29TH ST
Address NEW:
3101 E 29TH ST
Apply Date:
06/02/2025
Applicant:
Marisol Solorzano
Description:
REV2: Change exterior sheathing REV1: Replace 2x6 framing with 2x4 Bedroom Suite Addition and Enclose Porch
Permit Reviews
Permit Number - TC-RES-0625-02830
Permit Status: Complete
Permit Description: REV2: Change exterior sheathing
REV1: Replace 2x6 framing with 2x4
Bedroom Suite Addition and Enclose Porch
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 11/25/2025 | RESTAMP - RESIDENTIAL v.1 | 11/28/2025 | REQUIRES RESUBMIT |
| 08/28/2025 | RESIDENTIAL ADD/ALT v.4 | 10/02/2025 | REQUIRES RESUBMIT |
| 06/03/2025 | RESIDENTIAL ADD/ALT v.1 | 06/03/2025 | REQUIRES RESUBMIT |
| 05/28/2026 | RESIDENTIAL NEW DWELLING REVISION v.1 | 05/29/2026 | APPROVED |
| 10/24/2025 | RESIDENTIAL ADD/ALT v.5 | 11/03/2025 | REQUIRES RESUBMIT |
| 11/06/2025 | RESIDENTIAL ADD/ALT v.7 | 11/25/2025 | APPROVED |
| 08/19/2025 | RESIDENTIAL ADD/ALT v.3 | 08/19/2025 | REQUIRES RESUBMIT |
| 12/10/2025 | RESIDENTIAL ADD/ALT v.1 | 01/06/2026 | APPROVED |
| 03/31/2026 | RESIDENTIAL NEW DWELLING REVISION v.2 | 04/10/2026 | REQUIRES RESUBMIT |
| 03/13/2026 | RESIDENTIAL NEW DWELLING REVISION v.1 | 03/27/2026 | REQUIRES RESUBMIT |
| 04/16/2026 | RESIDENTIAL NEW DWELLING REVISION v.4 | 04/17/2026 | APPROVED |
| 04/15/2026 | RESIDENTIAL NEW DWELLING REVISION v.3 | 04/15/2026 | REQUIRES RESUBMIT |
| 11/06/2025 | RESIDENTIAL ADD/ALT v.6 | 11/06/2025 | REQUIRES RESUBMIT |
| 06/18/2025 | RESIDENTIAL ADD/ALT v.2 | 07/18/2025 | REQUIRES RESUBMIT |
Conditions
Permit Number - TC-RES-0625-02830
Permit Status: Complete
Permit Description: REV2: Change exterior sheathing
REV1: Replace 2x6 framing with 2x4
Bedroom Suite Addition and Enclose Porch
| Date | Description | Comments |
|---|---|---|
| 06/03/2025 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. | |
| 01/06/2026 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Complete
Permit Number: TC-RES-0625-02830
Permite Description: REV2: Change exterior sheathing
REV1: Replace 2x6 framing with 2x4
Bedroom Suite Addition and Enclose Porch
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/10/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Partial Pass | Walls are not framed per plan. A revision will be needed to match the site work. Plans call for 2x6 studs 16 o.c. but 2x4 at 16 oc are installed. Partial pass pending revision submittal to city. Proceed at own risk. |
Completed Inspections
Permit Status: Complete
Permit Number: TC-RES-0625-02830
Permit Description: REV2: Change exterior sheathing
REV1: Replace 2x6 framing with 2x4
Bedroom Suite Addition and Enclose Porch
Total Completed Inspections - 10
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/19/2026 | COT - RSPL - Rough Soil | Passed | ||
| 02/27/2026 | COT - RSBU - Excavation/Rebar/Zoning | Passed | ||
| 02/27/2026 | COT - RSBU - Preslab | Passed | ||
| 04/21/2026 | COT - RSBU - Roof Nailing | Passed | ||
| 04/21/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 4/21/26 Pass |
|
| 04/27/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | Approved. 4/27/2026 | |
| 07/01/2026 | COT - RSEL - Electrical Final | Passed | 07/01/2026 Verified branch circuit to addition AFCI breaker. Covered exposed electrical wires outside. |
|
| 07/01/2026 | COT - RSME - Mechanical Final | Passed | ||
| 07/01/2026 | COT - RSPL - Plumbing Final | Passed | ||
| 07/02/2026 | RSBU - Building Final | Passed | 7-2-26: building final approved. |