Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Residential Building - One or Two Family
Address:
3101 E 29TH ST
Address NEW:
3101 E 29TH ST
Apply Date:
06/02/2025
Applicant:
Marisol Solorzano
Description:
REV2: Change exterior sheathing REV1: Replace 2x6 framing with 2x4 Bedroom Suite Addition and Enclose Porch

Permit Reviews

Permit Number - TC-RES-0625-02830
Permit Status: Complete
Permit Description: REV2: Change exterior sheathing REV1: Replace 2x6 framing with 2x4 Bedroom Suite Addition and Enclose Porch
Start Date Submittal Complete Date Status  
11/25/2025 RESTAMP - RESIDENTIAL v.1 11/28/2025 REQUIRES RESUBMIT Review Details
08/28/2025 RESIDENTIAL ADD/ALT v.4 10/02/2025 REQUIRES RESUBMIT Review Details
06/03/2025 RESIDENTIAL ADD/ALT v.1 06/03/2025 REQUIRES RESUBMIT Review Details
05/28/2026 RESIDENTIAL NEW DWELLING REVISION v.1 05/29/2026 APPROVED Review Details
10/24/2025 RESIDENTIAL ADD/ALT v.5 11/03/2025 REQUIRES RESUBMIT Review Details
11/06/2025 RESIDENTIAL ADD/ALT v.7 11/25/2025 APPROVED Review Details
08/19/2025 RESIDENTIAL ADD/ALT v.3 08/19/2025 REQUIRES RESUBMIT Review Details
12/10/2025 RESIDENTIAL ADD/ALT v.1 01/06/2026 APPROVED Review Details
03/31/2026 RESIDENTIAL NEW DWELLING REVISION v.2 04/10/2026 REQUIRES RESUBMIT Review Details
03/13/2026 RESIDENTIAL NEW DWELLING REVISION v.1 03/27/2026 REQUIRES RESUBMIT Review Details
04/16/2026 RESIDENTIAL NEW DWELLING REVISION v.4 04/17/2026 APPROVED Review Details
04/15/2026 RESIDENTIAL NEW DWELLING REVISION v.3 04/15/2026 REQUIRES RESUBMIT Review Details
11/06/2025 RESIDENTIAL ADD/ALT v.6 11/06/2025 REQUIRES RESUBMIT Review Details
06/18/2025 RESIDENTIAL ADD/ALT v.2 07/18/2025 REQUIRES RESUBMIT Review Details

Conditions

Permit Number - TC-RES-0625-02830
Permit Status: Complete
Permit Description: REV2: Change exterior sheathing REV1: Replace 2x6 framing with 2x4 Bedroom Suite Addition and Enclose Porch
Date Description Comments
06/03/2025 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.
01/06/2026 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Outstanding Inspections

Permit Status: Complete
Permit Number: TC-RES-0625-02830
Permite Description: REV2: Change exterior sheathing REV1: Replace 2x6 framing with 2x4 Bedroom Suite Addition and Enclose Porch
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
03/10/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing N/A Partial Pass Walls are not framed per plan. A revision will be needed to match the site work. Plans call for 2x6 studs 16 o.c. but 2x4 at 16 oc are installed.
Partial pass pending revision submittal to city. Proceed at own risk.

Completed Inspections

Permit Status: Complete
Permit Number: TC-RES-0625-02830
Permit Description: REV2: Change exterior sheathing REV1: Replace 2x6 framing with 2x4 Bedroom Suite Addition and Enclose Porch
Total Completed Inspections - 10
Date Description Inspector Results Comments
02/19/2026 COT - RSPL - Rough Soil Passed
02/27/2026 COT - RSBU - Excavation/Rebar/Zoning Passed
02/27/2026 COT - RSBU - Preslab Passed
04/21/2026 COT - RSBU - Roof Nailing Passed
04/21/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 4/21/26
Pass
04/27/2026 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed Approved. 4/27/2026
07/01/2026 COT - RSEL - Electrical Final Passed 07/01/2026
Verified branch circuit to addition AFCI breaker. Covered exposed electrical wires outside.
07/01/2026 COT - RSME - Mechanical Final Passed
07/01/2026 COT - RSPL - Plumbing Final Passed
07/02/2026 RSBU - Building Final Passed 7-2-26: building final approved.