Inspection History Details
Inspection Status: Partial Pass
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/10/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Partial Pass | Walls are not framed per plan. A revision will be needed to match the site work. Plans call for 2x6 studs 16 o.c. but 2x4 at 16 oc are installed. Partial pass pending revision submittal to city. Proceed at own risk. |
|
| 04/21/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 4/21/26 Pass |