Start Date | Submittal | Complete Date | Status |
---|---|---|---|
09/19/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 09/20/2024 | APPROVED |
04/17/2024 | RESIDENTIAL NEW DWELLING v.1 | 05/20/2024 | REQUIRES RESUBMIT |
05/22/2024 | RESIDENTIAL NEW DWELLING v.2 | 06/28/2024 | APPROVED |
Conditions
Permit Number - TC-RES-0424-02260
Permit Status: Issued
Permit Description: SFR
Date | Description | Comments |
---|---|---|
06/28/2024 | Prior to Issuance: This project requires issuance of a Development Package (DP) permit prior to issuance of this permit. Prior to TCO/Final: This project requires full completion of a Development Package (DP) permit prior to Temporary C of O and/or final completion this permit. | |
05/02/2024 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
05/02/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Completed Inspections
Permit Status: Issued
Permit Number: TC-RES-0424-02260
Permit Description: SFR
Total Completed Inspections - 5
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/28/2024 | COT - RSPL - Rough Soil | Passed | 8/27/24: plumbing underground not per plan (revision required for changes made), tracer wire required at HCS connection, possible leak at master bath, release air from system to achieve 5 pounds of pressure. Shading material required due to rocky conditions. 8/28/24: corrections made. Shading provided at time of inspection. |
|
09/03/2024 | COT - RSBU - Preslab | Passed | 9/3/24: reinforcement at slab per plans ok to proceed with pour. | |
09/30/2024 | COT - RSBU - Roof Nailing | Passed | 9/23/24: Strapping at garage opening required per plans, anchor bolts at garage perimeter wall must be 32" o.c, Anchor bolts required 12" from edge of sill plate, shot pins required at interior walls, 2- king studs required at opening greater than 3' 6", anchor bolt spacing greater than 48" o.c at bearing perimeter walls. Plans call for 2- 2x12 at ledgers, window sills must not be higher than 44" high, correct hanger must be installed at truss, fire blocking required at garage, straps required at back patio entrance, no truss clacs provided, no ladder access. | |
10/02/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed | 10/2/2024 corrections were made. | |
10/02/2024 | COT - RSBU - Interior Shear Bracing | Passed |