Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Roof Nailing
Permit Number - TC-RES-0424-02260
Inspection Description - COT - RSBU - Roof Nailing
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/23/2024 | COT - RSBU - Roof Nailing | Re-inspection required | 9/23/24: Strapping at garage opening required per plans, anchor bolts at garage perimeter wall must be 32" o.c, Anchor bolts required 12" from edge of sill plate, shot pins required at interior walls, 2- king studs required at opening greater than 3' 6", anchor bolt spacing greater than 48" o.c at bearing perimeter walls. Plans call for 2- 2x12 at ledgers, window sills must not be higher than 44" high, correct hanger must be installed at truss, fire blocking required at garage, straps required at back patio entrance, no truss clacs provided, no ladder access. | |
09/30/2024 | COT - RSBU - Roof Nailing | Passed | 9/23/24: Strapping at garage opening required per plans, anchor bolts at garage perimeter wall must be 32" o.c, Anchor bolts required 12" from edge of sill plate, shot pins required at interior walls, 2- king studs required at opening greater than 3' 6", anchor bolt spacing greater than 48" o.c at bearing perimeter walls. Plans call for 2- 2x12 at ledgers, window sills must not be higher than 44" high, correct hanger must be installed at truss, fire blocking required at garage, straps required at back patio entrance, no truss clacs provided, no ladder access. |