Inspection Status: Re-inspection required
Inspection History: RSBU - Building Final
| Date |
Description |
Inspector |
Results |
Comments |
|
RSBU - Building Final |
|
Re-inspection required |
3/11/25: address required on home, sediment trap required at water heater, lock out caps required at A/C condenser refrigerant lines, exterior plastic piping must be coated for UV protection, all hose bibs must be insulated and wrapped. Light in storage not installed |
| 03/13/2025 |
RSBU - Building Final |
|
Passed |
3-13-25, all items noted from previous inspection have been corrected. Building final approved -okay to issue letter of completion. |