Permit: TC-RES-0225-00876
Permit Details
Status:
Inspections Complete
Type:
Residential Building - One or Two Family
Address:
301 W MELRIDGE ST
Address NEW:
301 W MELRIDGE ST
Apply Date:
02/17/2025
Applicant:
ROGER SORIANO
Description:
REV1: Added a shower head Kitchen and Bedroom Suite Extension; Enclose Carport into Great Room and Porch Addition
Permit Reviews
Permit Number - TC-RES-0225-00876
Permit Status: Inspections complete
Permit Description: REV1: Added a shower head
Kitchen and Bedroom Suite Extension; Enclose Carport into Great Room and Porch Addition
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/09/2025 | RESIDENTIAL NEW DWELLING v.4 | 06/09/2025 | APPROVED |
| 02/25/2025 | RESIDENTIAL NEW DWELLING v.1 | 02/25/2025 | REQUIRES RESUBMIT |
| 11/26/2025 | RESIDENTIAL NEW DWELLING REVISION v.1 | 11/26/2025 | REQUIRES RESUBMIT |
| 03/17/2025 | RESIDENTIAL NEW DWELLING v.2 | 04/16/2025 | REQUIRES RESUBMIT |
| 12/09/2025 | RESIDENTIAL NEW DWELLING REVISION v.2 | 12/18/2025 | APPROVED |
| 05/06/2025 | RESIDENTIAL NEW DWELLING v.3 | 06/05/2025 | REQUIRES RESUBMIT |
| 06/09/2025 | RESTAMP - RESIDENTIAL v.1 | 06/11/2025 | APPROVED |
Conditions
Permit Number - TC-RES-0225-00876
Permit Status: Inspections complete
Permit Description: REV1: Added a shower head
Kitchen and Bedroom Suite Extension; Enclose Carport into Great Room and Porch Addition
| Date | Description | Comments |
|---|---|---|
| 06/11/2025 | The Contractor you have added to your permit cannot be verified. Please contact staff to have the ROC number added to the account. | |
| 02/25/2025 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-RES-0225-00876
Permite Description: REV1: Added a shower head
Kitchen and Bedroom Suite Extension; Enclose Carport into Great Room and Porch Addition
Total Outstanding Inspections - 5
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/24/2025 | COT - RSBU - Excavation/Rebar/Zoning | N/A | Partial Pass | 7-24-25: partial pass-excavation/reinforcement and setbacks verified per plans. Underground plumbing inspection requires approval prior to pouring concrete. |
| 06/03/2026 | COT - RSEL - Electrical Final | N/A | Re-inspection required | 6-3-26: arch fault breakers/gfci's at kitchen receptacles are required, install hammer arrestor at dishwasher, install anti-tip device at stove, install 4" address numbers on home, missing sediment trap at gas water heater, install pressure relief valve at water heater, install hose bib and vacuum breaker, missing knockouts at panel, label breakers, install arch fault breakers/gfci's for habitable areas to include, kitchen and bedroom, exterior receptacles must be weather resistant gfci's, gfci receptacles are required at laundry room, missing concrete landings at sliding glass door & kitchen door, paint all exterior plastic at rooftop, missing shower tempered glass door, provide ladder for roof access, properly loop dishwasher lines. Schedule inspection for new porch- this was never inspected, Stopped inspection additional items may be noted. |
| 06/03/2026 | COT - RSME - Mechanical Final | N/A | Re-inspection required | 6-3-26: arch fault breakers/gfci's at kitchen receptacles are required, install hammer arrestor at dishwasher, install anti-tip device at stove, install 4" address numbers on home, missing sediment trap at gas water heater, install pressure relief valve at water heater, install hose bib and vacuum breaker, missing knockouts at panel, label breakers, install arch fault breakers/gfci's for habitable areas to include, kitchen and bedroom, exterior receptacles must be weather resistant gfci's, gfci receptacles are required at laundry room, missing concrete landings at sliding glass door & kitchen door, paint all exterior plastic at rooftop, missing shower tempered glass door, provide ladder for roof access, properly loop dishwasher lines. Schedule inspection for new porch- this was never inspected, Stopped inspection additional items may be noted. |
| 06/03/2026 | COT - RSPL - Plumbing Final | N/A | Re-inspection required | 6-3-26: arch fault breakers/gfci's at kitchen receptacles are required, install hammer arrestor at dishwasher, install anti-tip device at stove, install 4" address numbers on home, missing sediment trap at gas water heater, install pressure relief valve at water heater, install hose bib and vacuum breaker, missing knockouts at panel, label breakers, install arch fault breakers/gfci's for habitable areas to include, kitchen and bedroom, exterior receptacles must be weather resistant gfci's, gfci receptacles are required at laundry room, missing concrete landings at sliding glass door & kitchen door, paint all exterior plastic at rooftop, missing shower tempered glass door, provide ladder for roof access, properly loop dishwasher lines. Schedule inspection for new porch- this was never inspected, Stopped inspection additional items may be noted. |
| 06/03/2026 | RSBU - Building Final | N/A | Re-inspection required | 6-3-26: arch fault breakers/gfci's at kitchen receptacles are required, install hammer arrestor at dishwasher, install anti-tip device at stove, install 4" address numbers on home, missing sediment trap at gas water heater, install pressure relief valve at water heater, install hose bib and vacuum breaker, missing knockouts at panel, label breakers, install arch fault breakers/gfci's for habitable areas to include, kitchen and bedroom, exterior receptacles must be weather resistant gfci's, gfci receptacles are required at laundry room, missing concrete landings at sliding glass door & kitchen door, paint all exterior plastic at rooftop, missing shower tempered glass door, provide ladder for roof access, properly loop dishwasher lines. Schedule inspection for new porch- this was never inspected, Stopped inspection additional items may be noted. |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-RES-0225-00876
Permit Description: REV1: Added a shower head
Kitchen and Bedroom Suite Extension; Enclose Carport into Great Room and Porch Addition
Total Completed Inspections - 11
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/30/2025 | COT - RSPL - Rough Soil | Passed | 7-30-25: underground plumbing verified per plans and under test. Okay to backfill progress areas and pour concrete slab. | |
| 08/01/2025 | COT - RSBU - Preslab | Passed | 8/1/2025 approved. Okay for concrete placement. | |
| 08/01/2025 | COT - RSBU - Excavation/Rebar/Zoning | Passed | 8/1/2025 approved. Okay for concrete placement. | |
| 08/27/2025 | COT - RSBU - Roof Nailing | Passed | Approved. All corrections were made. 8/27/2025 | |
| 08/27/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | Approved. All corrections were made. 8/27/2025 | |
| 11/04/2025 | COT - RSPL - Gas Pressure Test | Passed | 11-4-25: gas pressure test approved. | |
| 12/19/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 12/19/2025 Approved per revised plan, verified all corrections to 11/04/2025 inspection. |
|
| 06/12/2026 | COT - RSEL - Electrical Final | Passed | 06/12/2026 Corrections made to prior inspection, verified rest of addition and rear patio. |
|
| 06/12/2026 | COT - RSME - Mechanical Final | Passed | 06/12/2026 Corrections made to prior inspection, verified rest of addition and rear patio. |
|
| 06/12/2026 | COT - RSPL - Plumbing Final | Passed | 06/12/2026 Corrections made to prior inspection, verified rest of addition and rear patio. |
|
| 06/12/2026 | RSBU - Building Final | Passed | 06/12/2026 Corrections made to prior inspection, verified rest of addition and rear patio. |