Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Issued
Type:
Residential Building - One or Two Family
Address:
933 N MILLER DR
Address NEW:
933 N MILLER DR
Apply Date:
01/20/2023
Applicant:
Grant Stratton
Description:
Replace Carport with Kitchen & Living Room Addition

Permit Reviews

Permit Number - TC-RES-0123-02267
Permit Status: Issued
Permit Description: Replace Carport with Kitchen & Living Room Addition
Start Date Submittal Complete Date Status  
05/03/2023 RESIDENTIAL NEW DWELLING v.2 06/14/2023 REQUIRES RESUBMIT Review Details
07/19/2023 RESIDENTIAL NEW DWELLING v.3 08/02/2023 REQUIRES RESUBMIT Review Details
08/23/2023 RESIDENTIAL NEW DWELLING v.4 09/07/2023 APPROVED Review Details
01/23/2023 RESIDENTIAL NEW DWELLING v.1 02/17/2023 REQUIRES RESUBMIT Review Details
10/26/2023 RESIDENTIAL NEW DWELLING v.1 11/09/2023 APPROVED Review Details

Conditions

Permit Number - TC-RES-0123-02267
Permit Status: Issued
Permit Description: Replace Carport with Kitchen & Living Room Addition
Date Description Comments
09/07/2023 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as a contact. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.

Outstanding Inspections

Permit Status: Issued
Permit Number: TC-RES-0123-02267
Permite Description: Replace Carport with Kitchen & Living Room Addition
Total Outstanding Inspections - 3
Last Inspection Date Description Inspector Results Comments
10/23/2023 COT - RSBU - Excavation/Rebar/Zoning N/A Re-inspection required 10/23/23: not ready, revision needed for underground plumbing, rebar coming out of existing footer for home needs to be 16 inches on center
02/08/2024 COT - RSME - Mechanical Final N/A Not Ready
02/08/2024 COT - RSEL - Electrical Final N/A Not Ready

Completed Inspections

Permit Status: Issued
Permit Number: TC-RES-0123-02267
Permit Description: Replace Carport with Kitchen & Living Room Addition
Total Completed Inspections - 9
Date Description Inspector Results Comments
11/14/2023 COT - RSBU - Preslab Passed
11/14/2023 COT - RSPL - Rough Soil Passed
12/19/2023 COT - RSBU - Masonry Pregrout Passed
01/19/2024 COT - RSBU - Roof Nailing Passed Rafters are properly installed and clips are nailed correctly. Roof sheathing is installed and properly nailed down to rafters. Okay to proceed with roofing material installation.
02/26/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 2/26/24: Wires have been secured within 8" of boxes, all metal boxes have romex connectors at wire entrance and ground wire is secured to grounding screw in box, conduit has been added from wall to subpanel for feeder wire. Okay to insulate and drywall walls and ceiling.
05/31/2024 RSBU - Building Final Passed Remodeling work is complete. All electrical and plumbing fixtures are operational. Okay to issue Certificate of Completion for this permit.
05/31/2024 COT - RSPL - Plumbing Final Passed Remodeling work is complete. All electrical and plumbing fixtures are operational. Okay to issue Certificate of Completion for this permit.
05/31/2024 COT - RSME - Mechanical Final Passed Remodeling work is complete. All electrical and plumbing fixtures are operational. Okay to issue Certificate of Completion for this permit.
05/31/2024 COT - RSEL - Electrical Final Passed Remodeling work is complete. All electrical and plumbing fixtures are operational. Okay to issue Certificate of Completion for this permit.

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-SEWER PLANS TO BE ALTERED_V1.PDF DOCUMENTS VIEW
KITCHEN SEWER NARRATIVE_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
OWNER AFFIDAVIT_V1.PDF DOCUMENTS VIEW
CONS-PLANS UPDATED 6.27.23_V3.PDF DOCUMENTS VIEW
NOTICE OF DEMOLITION_V1.PDF DOCUMENTS VIEW
OWNER AFFIDAVIT_V1.PDF DOCUMENTS VIEW