Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Inspections
Type:
Model Building Permit
Apply Date:
08/29/2025
Applicant:
Celina Rodriguez
Description:
Mirador Ridge Blossom 1465 Plan (Model master plan TC-MDP-0725-00408)

Permit Reviews

Permit Number - TC-MDP-0825-00458
Permit Status: Inspections
Permit Description: Mirador Ridge Blossom 1465 Plan (Model master plan TC-MDP-0725-00408)
Start Date Submittal Complete Date Status  
09/11/2025 SITE FROM MODEL PERMIT - PRODUCTION v.3 09/15/2025 APPROVED Review Details
09/02/2025 SITE FROM MODEL PERMIT - PRODUCTION v.1 09/10/2025 REQUIRES RESUBMIT Review Details
09/10/2025 SITE FROM MODEL PERMIT - PRODUCTION v.2 09/10/2025 REQUIRES RESUBMIT Review Details

Outstanding Activity Conditions

Permit Number - TC-MDP-0825-00458
Permit Status: Inspections
Permit Description: Mirador Ridge Blossom 1465 Plan (Model master plan TC-MDP-0725-00408)
Total Outstanding Activity Conditions - 5
Date Name
08/20/2025 Submit the Air Leakage & Duct Tightness Test Report completed by an Approved Special Inspector prior to Final Inspections.
08/20/2025 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/
09/03/2025 Post-Installed Anchor Inspection Report is required.
09/03/2025 Post-Tension Inspection Report is required.
09/03/2025 SPECIAL INSPECTION FOR SITE PREPARATION IS REQUIRED.

Conditions

Permit Number - TC-MDP-0825-00458
Permit Status: Inspections
Permit Description: Mirador Ridge Blossom 1465 Plan (Model master plan TC-MDP-0725-00408)
Date Description Comments
08/20/2025 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.
08/20/2025 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900.

Outstanding Inspections

Permit Status: Inspections
Permit Number: TC-MDP-0825-00458
Permite Description: Mirador Ridge Blossom 1465 Plan (Model master plan TC-MDP-0725-00408)
Total Outstanding Inspections - 7
Last Inspection Date Description Inspector Results Comments
09/19/2025 COT - RSPL - Sewer N/A Not Ready
10/01/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing N/A Not Ready 10.1.25
Work being conducted on site, trip hazards and other hazards prevalent along with visual obstruction. Site not suitable for inspection. Reinspection requires fee.
09/30/2025 COT - RSBU - Roof Nailing N/A Re-inspection required 9/30/25: fasteners at shear walls shall penetrate no more than 1/8", fasteners at shear wall 11 shall be spaced at 4" at edge and 12" at field, Anchor bolts at shear wall 11 are required at 23" o.c, anchor bolt spacing at exterior walls is 72" o.c (span greater than 72" on north wall), anchor bolts shall be placed no closer than 7X the bolt diameter from edge of sill plate, 2x6 Ledge at back patio must be fastened with 4 16d nails at 16" o.c, 2x6 rafters at back patio must be spaced at 16" o.c,RSP4 spacing should be 32" o.c (missed on south wall, improperly installed MASA clip at north wall midway, 7 fasteners minimum at masa clip to suffice for 1/2" anchor bolts, shot pins must be spaced at 36" o.c at interior non-load bearing walls. Roof sheathing at garage must be properly fastened, anchor bolts must be in middle third of plate.
11/17/2025 RSBU - Building Final N/A Partial Pass Okay for level 3 TCO for use as a sales model.
11/17/2025 ENGR Engineering Final N/A Partial Pass Okay for level 3 TCO for use as a sales model.
11/17/2025 COT - RSPL - Plumbing Final N/A Not Ready
11/17/2025 COT - RSME - Mechanical Final N/A Not Ready

Completed Inspections

Permit Status: Inspections
Permit Number: TC-MDP-0825-00458
Permit Description: Mirador Ridge Blossom 1465 Plan (Model master plan TC-MDP-0725-00408)
Total Completed Inspections - 13
Date Description Inspector Results Comments
09/19/2025 COT - RSPL - Rough Soil Passed
09/19/2025 COT - RSPL - Yard Water Line Passed
09/23/2025 COT - RSBU - Excavation/Rebar/Zoning Passed
09/23/2025 COT - RSBU - Preslab Passed
09/23/2025 COT - RSEL - Electrical Underground Passed
09/23/2025 COT - RSEL - Grounding/Bonding Passed
10/03/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed
10/03/2025 COT - RSBU - Roof Nailing Passed
10/08/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 10-8-25: intermediates approved-okay to continue with construction.
10/08/2025 COT - RSPL - Gas Pressure Test Passed 10-8-25: gas pressure test approved.
10/13/2025 COT - RSBU - Interior Shear Bracing Passed
11/17/2025 COT - RSEL - Outdoor Lighting Passed
12/01/2025 BULD - Electrical Clearance Passed 12.1.25
approved for ECO

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
MIRADOR RIDGE - LOT 4 START_V3.PDF DOCUMENTS VIEW
MRB 4 SIC-2025-08-29_V1.PDF DOCUMENTS VIEW