Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Not Ready
Inspection History: COT - RSEL - Electrical Final
Permit Number - TC-MDP-0825-00458
Inspection Description - COT - RSEL - Electrical Final
Inspection Status - Not Ready
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/08/2026 | COT - RSEL - Electrical Final | Not Ready | 01/08/2026 Not ready. |
|
| 01/20/2026 | COT - RSEL - Electrical Final | Re-inspection required | 1/20/26: hvac condenser Disconnect box requires 3' clearance in front, accessible route does not meet requirements, properly secure conduit at wall will appropriate fasteners, KO at main panel must be sealed, thermostat shall be no higher than 48" above finish floor, no attic access, no garage access, domestic water has not been hooked up, sewer connection has not been made, expansion tank required at water heater due to a closed loop system. Stopped inspection more items may be added. Please call future inspections under commercial permit for sales office and model home (this permit is directly correlated with the SFR) |