Permit: TC-MDP-0625-00323
Permit Details
Status:
Inspections
Type:
Model Building Permit
Address:
5740 S NOGALES HY
Address NEW:
5740 S NOGALES HY
Apply Date:
06/06/2025
Applicant:
Jorge Navarro
Description:
Duplex (Model master plan TC-MDP-0724-00807)
Permit Reviews
Permit Number - TC-MDP-0625-00323
Permit Status: Inspections
Permit Description: Duplex (Model master plan TC-MDP-0724-00807)
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/05/2025 | SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.3 | 09/19/2025 | REQUIRES RESUBMIT |
| 11/14/2025 | SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.5 | 11/20/2025 | APPROVED |
| 06/10/2025 | SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1 | 06/26/2025 | REQUIRES RESUBMIT |
| 01/22/2026 | SITE FROM MODEL TEMPLATE INFILL BUILDERS REVISION v.1 | 01/30/2026 | APPROVED |
| 08/07/2025 | SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.2 | 08/07/2025 | REQUIRES RESUBMIT |
| 11/04/2025 | SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.4 | 11/07/2025 | REQUIRES RESUBMIT |
| 12/05/2025 | ADMINISTRATIVE v.1 | 12/05/2025 | REQUIRES RESUBMIT |
| 11/20/2025 | RESTAMP - RESIDENTIAL v.1 | 12/05/2025 | APPROVED |
| 02/18/2026 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 02/20/2026 | APPROVED |
Conditions
Permit Number - TC-MDP-0625-00323
Permit Status: Inspections
Permit Description: Duplex (Model master plan TC-MDP-0724-00807)
| Date | Description | Comments |
|---|---|---|
| 06/10/2025 | The plan submitted shows to be for a duplex BLDG 5 Units 9 & 10. The location 5740 S Nogales Hy does not have BLDG 5 attached to the address and a pre issuance addressing condition has been placed on permit. Please contact Pima County Addressing at addressing@pima.gov or 520-724-9512 to verify/add the BLDG number. An address change request is required to have the bldg and units added to this permit. In addition, if the BLDG and units end up different from the ones specified on your site plan and resubmittal may be required as well. | |
| 06/03/2025 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. | |
| 06/03/2025 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. | |
| 06/24/2025 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0625-00323
Permite Description: Duplex (Model master plan TC-MDP-0724-00807)
Total Outstanding Inspections - 13
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/31/2026 | COT - RSEL - Electrical Underground | N/A | Not Applicable | |
| 09/25/2026 | COT - BULD - SWG Clearance | N/A | Not Applicable | 9/25/26: not applicable. |
| 09/25/2026 | COT - RSBU - Interior Shear Bracing | N/A | Re-inspection required | 9/25/26: unit 10-a drywall screw inspection was not done, therefore, a magnet test is required, an anti tip device is required for stove, gas valve was not installed at stove as indicated on plans-submit a revision to the city showing change, arch fault breakers required for every habitable area, install a cvpvc pressure relief valve-cannot have a flex to cvpvc, laundry room receptacle must be gfci, insulate hose bib, missing back water valve, install a 90 degree elbow on condensation line on north side, EV Charger must contain car decal on receptacle, install bubble covers on exterior gfci receptacles, toilet in bedroom requires a 15" clearance from shower, submit as-built sewer plan as requested from G.Armenta-see notes for more information, provide ladder for roof access. Unit 9-anti tip device on stove, seal water closets, gfci receptacles required at laundry room. Stopped inspection-additional items may be added. |
| 09/25/2026 | COT - RSEL - Electrical Final | N/A | Re-inspection required | 9/25/26: unit 10-a drywall screw inspection was not done, therefore, a magnet test is required, an anti tip device is required for stove, gas valve was not installed at stove as indicated on plans-submit a revision to the city showing change, arch fault breakers required for every habitable area, install a cvpvc pressure relief valve-cannot have a flex to cvpvc, laundry room receptacle must be gfci, insulate hose bib, missing back water valve, install a 90 degree elbow on condensation line on north side, EV Charger must contain car decal on receptacle, install bubble covers on exterior gfci receptacles, toilet in bedroom requires a 15" clearance from shower, submit as-built sewer plan as requested from G.Armenta-see notes for more information, provide ladder for roof access. Unit 9-anti tip device on stove, seal water closets, gfci receptacles required at laundry room. Stopped inspection-additional items may be added. |
| 09/25/2026 | COT - RSEL - Outdoor Lighting | N/A | Re-inspection required | 9/25/26: install bubble covers that are " heavy duty while in use." |
| 09/25/2026 | COT - RSME - Mechanical Final | N/A | Re-inspection required | 9/25/26: unit 10-a drywall screw inspection was not done, therefore, a magnet test is required, an anti tip device is required for stove, gas valve was not installed at stove as indicated on plans-submit a revision to the city showing change, arch fault breakers required for every habitable area, install a cvpvc pressure relief valve-cannot have a flex to cvpvc, laundry room receptacle must be gfci, insulate hose bib, missing back water valve, install a 90 degree elbow on condensation line on north side, EV Charger must contain car decal on receptacle, install bubble covers on exterior gfci receptacles, toilet in bedroom requires a 15" clearance from shower, submit as-built sewer plan as requested from G.Armenta-see notes for more information, provide ladder for roof access. Unit 9-anti tip device on stove, seal water closets, gfci receptacles required at laundry room. Stopped inspection-additional items may be added. |
| 09/25/2026 | COT - RSPL - Backwater Valve | N/A | Re-inspection required | 9/25/26: unit 10-a drywall screw inspection was not done, therefore, a magnet test is required, an anti tip device is required for stove, gas valve was not installed at stove as indicated on plans-submit a revision to the city showing change, arch fault breakers required for every habitable area, install a cvpvc pressure relief valve-cannot have a flex to cvpvc, laundry room receptacle must be gfci, insulate hose bib, missing back water valve, install a 90 degree elbow on condensation line on north side, EV Charger must contain car decal on receptacle, install bubble covers on exterior gfci receptacles, toilet in bedroom requires a 15" clearance from shower, submit as-built sewer plan as requested from G.Armenta-see notes for more information, provide ladder for roof access. Unit 9-anti tip device on stove, seal water closets, gfci receptacles required at laundry room. Stopped inspection-additional items may be added. |
| 09/25/2026 | COT - RSPL - Gas Pressure Test | N/A | Not Applicable | 9/25/26: not applicable. |
| 09/25/2026 | COT - RSPL - Plumbing Final | N/A | Re-inspection required | 9/25/26: unit 10-a drywall screw inspection was not done, therefore, a magnet test is required, an anti tip device is required for stove, gas valve was not installed at stove as indicated on plans-submit a revision to the city showing change, arch fault breakers required for every habitable area, install a cvpvc pressure relief valve-cannot have a flex to cvpvc, laundry room receptacle must be gfci, insulate hose bib, missing back water valve, install a 90 degree elbow on condensation line on north side, EV Charger must contain car decal on receptacle, install bubble covers on exterior gfci receptacles, toilet in bedroom requires a 15" clearance from shower, submit as-built sewer plan as requested from G.Armenta-see notes for more information, provide ladder for roof access. Unit 9-anti tip device on stove, seal water closets, gfci receptacles required at laundry room. Stopped inspection-additional items may be added. |
| 09/25/2026 | COT - RSPL - Sewer | N/A | Re-inspection required | 9/25/26: unit 10-a drywall screw inspection was not done, therefore, a magnet test is required, an anti tip device is required for stove, gas valve was not installed at stove as indicated on plans-submit a revision to the city showing change, arch fault breakers required for every habitable area, install a cvpvc pressure relief valve-cannot have a flex to cvpvc, laundry room receptacle must be gfci, insulate hose bib, missing back water valve, install a 90 degree elbow on condensation line on north side, EV Charger must contain car decal on receptacle, install bubble covers on exterior gfci receptacles, toilet in bedroom requires a 15" clearance from shower, submit as-built sewer plan as requested from G.Armenta-see notes for more information, provide ladder for roof access. Unit 9-anti tip device on stove, seal water closets, gfci receptacles required at laundry room. Stopped inspection-additional items may be added. |
| 09/25/2026 | ENGR Engineering Final | N/A | Not Ready | |
| 09/25/2026 | RSBU - Building Final | N/A | Re-inspection required | 9/25/26: unit 10-a drywall screw inspection was not done, therefore, a magnet test is required, an anti tip device is required for stove, gas valve was not installed at stove as indicated on plans-submit a revision to the city showing change, arch fault breakers required for every habitable area, install a cvpvc pressure relief valve-cannot have a flex to cvpvc, laundry room receptacle must be gfci, insulate hose bib, missing back water valve, install a 90 degree elbow on condensation line on north side, EV Charger must contain car decal on receptacle, install bubble covers on exterior gfci receptacles, toilet in bedroom requires a 15" clearance from shower, submit as-built sewer plan as requested from G.Armenta-see notes for more information, provide ladder for roof access. Unit 9-anti tip device on stove, seal water closets, gfci receptacles required at laundry room. Stopped inspection-additional items may be added. |
| 09/25/2026 | RSBU - Building Progress | N/A | Re-inspection required | 9/25/26: unit 10-a drywall screw inspection was not done, therefore, a magnet test is required, an anti tip device is required for stove, gas valve was not installed at stove as indicated on plans-submit a revision to the city showing change, arch fault breakers required for every habitable area, install a cvpvc pressure relief valve-cannot have a flex to cvpvc, laundry room receptacle must be gfci, insulate hose bib, missing back water valve, install a 90 degree elbow on condensation line on north side, EV Charger must contain car decal on receptacle, install bubble covers on exterior gfci receptacles, toilet in bedroom requires a 15" clearance from shower, submit as-built sewer plan as requested from G.Armenta-see notes for more information, provide ladder for roof access. Unit 9-anti tip device on stove, seal water closets, gfci receptacles required at laundry room. Stopped inspection-additional items may be added. |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0625-00323
Permit Description: Duplex (Model master plan TC-MDP-0724-00807)
Total Completed Inspections - 9
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/12/2026 | COT - RSBU - Excavation/Rebar/Zoning | Passed | 02/12/2026 Duplex Unit 9 & 10. Approved per site plan, foundation details. Okay for concrete placement. |
|
| 02/24/2026 | COT - RSPL - Rough Soil | Passed | 2-24-26: underground plumbing for unit 7 & 8 verified per plans & under test. Okay to backfill progress areas using shading materials. | |
| 03/31/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | ||
| 04/03/2026 | COT - RSBU - Roof Nailing | Passed | 4-3-26: previously inspected & approved by O.Soares on 3/31/26. | |
| 05/27/2026 | COT - RSEL - Grounding/Bonding | Passed | 5-27-26: Building 5-grounding/bonding for unit's 11 & 12 approved. | |
| 06/02/2026 | COT - RSPL - Yard Water Line | Passed | ||
| 08/31/2026 | BULD - Electrical Clearance | Passed | Passed CLEARANCE ECO | |
| 09/25/2026 | COT - RSBU - Preslab | Passed | 9/25/26: approved. | |
| 09/25/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 9/25/26: approved. |