Permit: TC-MDP-0524-00565
Permit Details
Status:
Inspections Complete
Type:
Model Building Permit
Address:
6137 E FALCONRY TR
Address NEW:
6137 E FALCONRY TR
Apply Date:
05/01/2024
Applicant:
Alonzo Martinez
Description:
Blackhawk H30A Model Plan
Permit Reviews
Permit Number - TC-MDP-0524-00565
Permit Status: Inspections complete
Permit Description: Blackhawk H30A Model Plan
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 05/02/2024 | SITE FROM MODEL PERMIT - SUBDIVISION v.1 | 05/13/2024 | APPROVED |
| 06/25/2025 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 06/25/2025 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0524-00565
Permit Status: Inspections complete
Permit Description: Blackhawk H30A Model Plan
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 05/01/2024 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. |
Conditions
Permit Number - TC-MDP-0524-00565
Permit Status: Inspections complete
Permit Description: Blackhawk H30A Model Plan
| Date | Description | Comments |
|---|---|---|
| 05/14/2024 | The Contractor you have added to your permit cannot be verified. Please contact staff to have the ROC number added to the account. | |
| 05/08/2024 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. | |
| 05/08/2024 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. | |
| 05/01/2024 | Post-Tension Inspection Report is required. | |
| 05/01/2024 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
| 05/08/2024 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. | |
| 05/08/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0524-00565
Permite Description: Blackhawk H30A Model Plan
Total Outstanding Inspections - 8
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/12/2025 | COT - RSEL - Electrical Underground | N/A | Not Applicable | |
| 05/12/2025 | BULD - Electrical Clearance | N/A | Re-inspection required | Ground rods not set, missing address label |
| 06/16/2025 | COT - RSBU - Roof Nailing | N/A | Re-inspection required | 6-16-25: see previous notes related to |
| 06/18/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Re-inspection required | 6-13-25: firefoam chutes at garage, seal penetrations t-ply throughout, DWV not under test, tears on flex at kitchen area, block register on 3 sides at master bedroom, 12" clearance is required between pex and lights-block using osb, drywall, 2x4, plywood, block open space above a/c whip on east side of family room.. 6-16-25: shower not under test, firefoam garage chutes, staple awg within 12" of exiting coach light at garage chute, seal vapor barrier behind garage chute, add 1 "staples to t-ply at garage 3"o.c. at edges and in the field, block any pex within 12" of any lights using osb, plywood, 2x4's, or drywall. 6/18/25: staple romex within 12" of box, seal all penetrations through vapor barrier. Shear wall fasteners not per plan and shall be no closer than 3/8" from edge, nail plates at rough-ins with 1 1/4" of face of 2x. |
| 06/18/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Re-inspection required | 5-27-25, add anchor bolts at marked locations, staple T-ply at upstairs south wall at base, add nails sill to decking at marked locations, make corrections to T-ply located at west wall, add shot pins to marked locations and nails to roof sheathing at southwest location. 6-4-25: correct blocking /sheathing along east side of garage by properly nailing to framing and install HTT5 at entry of southeast corner of garage. NOTE; Framing reinspect but home already lathed. 6-13-25: add blocking behind t-ply at garage and staple 3" o.c.. throughout, add blocking above a/c whip on eastside of family room and reschedule when ready.Submit a letter to the city for review/approval documenting that exterior clips/sheathing was done per plans and meets the 2018 IRC. 6-16-25: add 1 "staples to t-ply at garage 3"o.c. at edges and in the field. 6/18/25: Shear wall fasteners not per plan and shall be no closer than 3/8" from edge. |
| 07/07/2025 | COT - RSBU - Interior Shear Bracing | N/A | Re-inspection required | 7-7-25: screws shall be no closer than 3/8" from edges/joints and cannot penetrate more than 1/16". Add screws along base of drywall throughout and screws using listed above Information/details. |
| 09/10/2025 | COT - RSEL - Electrical Final | N/A | Re-inspection required | 9.10.25 Garage must be on separate circuit |
| 09/10/2025 | RSBU - Building Final | N/A | Re-inspection required | 9.10.25 Garage must be on separate circuit |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0524-00565
Permit Description: Blackhawk H30A Model Plan
Total Completed Inspections - 18
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/12/2025 | COT - RSPL - Rough Soil | Passed | Passed 5/12/25 ok to backfill | |
| 05/12/2025 | COT - RSPL - Sewer | Passed | Passed 5/12/25 ok to backfill | |
| 05/12/2025 | COT - RSPL - Yard Water Line | Passed | Passed 5/12/25 ok to backfill | |
| 05/20/2025 | BULD - Electrical Clearance | Passed | 5-20-25, panel okay to be energized. ECO clearance sent to TEP. | |
| 05/20/2025 | COT - RSBU - Excavation/Rebar/Zoning | Passed | 5-20-25, preslab,excavation/reinforcement/setbacks verified per approved plans. Okay to pour concrete. | |
| 05/20/2025 | COT - RSBU - Preslab | Passed | 5-20-25, preslab,excavation/reinforcement/setbacks verified per approved plans. Okay to pour concrete. | |
| 06/13/2025 | COT - RSEL - Grounding/Bonding | Passed | 6-13-25: approved. | |
| 06/13/2025 | COT - RSPL - Gas Pressure Test | Passed | 6-13-25: approved. | |
| 06/20/2025 | COT - RSBU - Roof Nailing | Passed | ||
| 06/20/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | ||
| 06/20/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | ||
| 07/09/2025 | COT - RSBU - Interior Shear Bracing | Passed | 7-9-25: okay for tape & texture. | |
| 08/08/2025 | COT - BULD - SWG Clearance | Passed | 8.8.25 SWG clearance approved |
|
| 09/11/2025 | RSBU - Building Progress | Passed | ||
| 09/10/2025 | COT - RSEL - Outdoor Lighting | Passed | 9.10.25 APPROVED |
|
| 09/10/2025 | COT - RSME - Mechanical Final | Passed | 9.10.25 APPROVED |
|
| 09/10/2025 | COT - RSPL - Plumbing Final | Passed | 9.10.25 APPROVED |
|
| 09/15/2025 | ENGR Engineering Final | Passed | Site is clear and accessible; complete in accordance with approved plans. |