Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-MDP-0524-00565

Parcel: 140443840


Addresses:

6137 E FALCONRY TR

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
05/27/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 5-27-25, add anchor bolts at marked locations, staple T-ply at upstairs south wall at base, add nails sill to decking at marked locations, make corrections to T-ply located at west wall, add shot pins to marked locations and nails to roof sheathing at southwest location.
06/04/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 6-4-25: correct blocking /sheathing along east side of garage by properly nailing to framing and install HTT5 at entry of southeast corner of garage. NOTE; Framing reinspect but home already lathed.
06/13/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required (with fee) 6-13-25: add blocking behind t-ply at garage and staple 3" o.c.. throughout, add blocking above a/c whip on eastside of family room and reschedule when ready.Submit a letter to the city for review/approval documenting that exterior clips/sheathing was done per plans and meets the 2018 IRC.
06/16/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 6-16-25: add 1 "staples to t-ply at garage 3"o.c. at edges and in the field.
06/18/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 5-27-25, add anchor bolts at marked locations, staple T-ply at upstairs south wall at base, add nails sill to decking at marked locations, make corrections to T-ply located at west wall, add shot pins to marked locations and nails to roof sheathing at southwest location.
6-4-25: correct blocking /sheathing along east side of garage by properly nailing to framing and install HTT5 at entry of southeast corner of garage. NOTE; Framing reinspect but home already lathed.
6-13-25: add blocking behind t-ply at garage and staple 3" o.c.. throughout, add blocking above a/c whip on eastside of family room and reschedule when ready.Submit a letter to the city for review/approval documenting that exterior clips/sheathing was done per plans and meets the 2018 IRC.
6-16-25: add 1 "staples to t-ply at garage 3"o.c. at edges and in the field.
6/18/25: Shear wall fasteners not per plan and shall be no closer than 3/8" from edge.
06/20/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed