Permit: TC-MDP-0324-00311
Permit Details
Status:
Inspections Complete
Type:
Model Building Permit
Address:
150 W AVIATION DR UNIT 1
Address NEW:
150 W AVIATION DR UNIT 1
Apply Date:
03/18/2024
Applicant:
Abraham Andraux
Description:
Carlos MP 1440 SFR
Permit Reviews
Permit Number - TC-MDP-0324-00311
Permit Status: Inspections complete
Permit Description: Carlos MP 1440 SFR
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/19/2024 | SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1 | 04/04/2024 | REQUIRES RESUBMIT |
| 05/23/2024 | SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.2 | 05/23/2024 | REQUIRES RESUBMIT |
| 09/19/2024 | SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1 | 09/30/2024 | APPROVED |
| 06/05/2024 | RESTAMP - RESIDENTIAL v.1 | 06/05/2024 | APPROVED |
| 05/24/2024 | SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.3 | 06/05/2024 | APPROVED |
| 09/13/2024 | RESTAMP - RESIDENTIAL v.1 | 09/17/2024 | APPROVED |
| 05/06/2025 | SITE FROM MODEL TEMPLATE INFILL BUILDERS REVISION v.1 | 05/06/2025 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0324-00311
Permit Status: Inspections complete
Permit Description: Carlos MP 1440 SFR
Total Outstanding Activity Conditions - 3
| Date | Name |
|---|---|
| 03/18/2024 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. |
| 03/18/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
| 08/20/2025 | A new site plan is required to be submitted to reflect the address change request showing the unit 1 that was added. In addition to your site plan, please provide a letter that states "Address change only" |
Conditions
Permit Number - TC-MDP-0324-00311
Permit Status: Inspections complete
Permit Description: Carlos MP 1440 SFR
| Date | Description | Comments |
|---|---|---|
| 03/20/2024 | Please contact Pima County Addressing to resolve issue. Addressing@pima.gov or 520-724-9512 | |
| 06/05/2024 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. | |
| 03/18/2024 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0324-00311
Permite Description: Carlos MP 1440 SFR
Total Outstanding Inspections - 9
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/07/2024 | COT - RSBU - Roof Nailing | N/A | Re-inspection required | Several areas require additional nailing |
| 10/04/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Re-inspection required | 10-4-24, missing lateral bracing-see truss calculations for details. Also, several areas on roof require additional nailing, add shot pins throughout interior framing, missing/loose anchor bolts. Exterior clip requires additional nailing-areas in question marked |
| 10/15/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Re-inspection required | 10-15-24, intermediate not approved and Reinspection required. Electrical is not per approved plans (#of circuits do not match approved plans),customer added a pantry that is not on plans. Customer needs to revise plans or remove pantry altogether. |
| 10/16/2024 | COT - RSBU - Interior Shear Bracing | N/A | Partial Pass | Several areas require additional nailing 10/7/24: shot pins required 24" o.c at interior walls, damaged sill plates must be replaced, shot pins required 6" from edge of sill plate, exterior sheathing must be properly fastened (fasteners shall be 3/8" from edge and not penetrate more than 1/8". 10/9/24: this is inspection is for drywall nailing. 10-15-24, listed items from 10-7-24 have been corrected. |
| 07/21/2025 | COT - RSBU - Excavation/Rebar/Zoning | N/A | Canceled | 7-21-25: canceled by contractor. |
| 07/22/2025 | COT - BULD - SWG Clearance | N/A | Not Applicable | |
| 07/21/2025 | COT - RSBU - Preslab | N/A | Canceled | 7-21-25: canceled by contractor. |
| 07/21/2025 | COT - RSEL - Grounding/Bonding | N/A | Canceled | 7-21-25: canceled by contractor. |
| 09/12/2025 | ENGR Engineering Final | N/A | Not Ready | Driveway is not paved. Accessible Route will need to extend to the right of way at street (mailbox area). One of the entrances is no step- good entryway and is on accessible route. Pavers set in concrete are acceptable. Extend Accessible Route to the sidewalk. |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0324-00311
Permit Description: Carlos MP 1440 SFR
Total Completed Inspections - 21
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/20/2024 | COT - RSPL - Rough Soil | Passed | Okay to backfill. Shading required. 9/20/2024 | |
| 10/07/2024 | COT - RSBU - Roof Nailing | Passed | ||
| 10/09/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | ||
| 10/15/2024 | COT - RSPL - Sewer | Passed | 10-15-24, sewer connection verified and approved. | |
| 10/17/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 10/17/2024 approved. Corrections were made. | |
| 12/24/2024 | COT - RSPL - Yard Water Line | Passed | 12/24/24 pass ok to backfill. | |
| 07/22/2025 | COT - RSBU - Interior Shear Bracing | Passed | ||
| 07/22/2025 | COT - RSBU - Excavation/Rebar/Zoning | Passed | ||
| 07/22/2025 | COT - RSBU - Preslab | Passed | ||
| 07/22/2025 | COT - RSEL - Grounding/Bonding | Passed | ||
| 07/22/2025 | RSBU - Building Progress | Passed | ||
| 07/25/2025 | COT - RSEL - Electrical Underground | Passed | 7.25.25 Wires pulled in as requested. Ok to proceed. |
|
| 07/30/2025 | COT - RSPL - Backwater Valve | Passed | 7-30-25: backwater valve approved-Okay to backfill. | |
| 08/14/2025 | BULD - Electrical Clearance | Passed | 8/14/25 TEP CLEARANCE: ECO |
|
| 09/12/2025 | COT - RSEL - Outdoor Lighting | Passed | Passed 9/12/25 | |
| 09/12/2025 | COT - RSEL - Electrical Final | Passed | Passed 9/12/25 | |
| 09/12/2025 | COT - RSME - Mechanical Final | Passed | Passed 9/12/25 | |
| 09/12/2025 | COT - RSPL - Gas Pressure Test | Passed | Passed 9/12/25 | |
| 09/12/2025 | COT - RSPL - Plumbing Final | Passed | Passed 9/12/25 | |
| 09/12/2025 | RSBU - Building Final | Passed | Passed 9/12/25 | |
| 09/18/2025 | ENGR Engineering Final | Passed |