Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-MDP-0124-00126
Permit Details
Apply Date:
02/26/2024
Applicant:
Paula Hinman
Description:
Blackhawk - T698 - Layla
Permit Reviews
Permit Number - TC-MDP-0124-00126
Permit Status: Inspections complete
Permit Description: Blackhawk - T698 - Layla
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
03/12/2024 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 03/22/2024 | APPROVED |
02/27/2024 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 03/08/2024 | APPROVED |
08/12/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 08/14/2024 | APPROVED |
Conditions
Permit Number - TC-MDP-0124-00126
Permit Status: Inspections complete
Permit Description: Blackhawk - T698 - Layla
Date | Description | Comments |
---|---|---|
03/06/2024 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. | |
03/06/2024 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. | |
03/06/2024 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. | |
03/06/2024 | Post-Tension Inspection Report is required. | |
09/25/2023 | Post-Tension Inspection Report is required. | |
08/14/2024 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
12/22/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
01/22/2024 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. | |
12/22/2023 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. | |
08/14/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. | |
09/25/2023 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0124-00126
Permite Description: Blackhawk - T698 - Layla
Total Outstanding Inspections - 4
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/21/2024 | COT - RSEL - Grounding/Bonding | N/A | Re-inspection required | 6/21/24:seal all penetrations through second floor decking, over notched bearing studs at garage require stud-shoe, seal penetration for tubs at second floor decking, gas pipe needs to be clamped to support, properly support condensation drains for furnace. STOPPED INSPECTION MORE ITEMS MAY BE ADDED. |
06/21/2024 | BULD - Electrical Clearance | N/A | Re-inspection required | 6/21/24:seal all penetrations through second floor decking, over notched bearing studs at garage require stud-shoe, seal penetration for tubs at second floor decking, gas pipe needs to be clamped to support, properly support condensation drains for furnace. STOPPED INSPECTION MORE ITEMS MAY BE ADDED. |
06/21/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Re-inspection required | 6/21/24:seal all penetrations through second floor decking, over notched bearing studs at garage require stud-shoe, seal penetration for tubs at second floor decking, gas pipe needs to be clamped to support, properly support condensation drains for furnace. STOPPED INSPECTION MORE ITEMS MAY BE ADDED. |
08/29/2024 | ENGR Engineering Final | N/A | Partial Pass | Contractor needs to remove the trash bins in front of the house and the Porta potty |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0124-00126
Permit Description: Blackhawk - T698 - Layla
Total Completed Inspections - 21