Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date |
Description |
Inspector |
Results |
Comments |
| 05/16/2024 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Re-inspection required |
Missing 2-2x4 studs for GT at front porch, missing 2-2x4 studs for post above at front porch, missing 2-2x4 studs for post above at front left side of garage per plans, missing second king stud at each end for back porch sliding doors, add blocking between floors to allow continuous load transfer from second floor down to first floor per floor framing plan note under note 8., right side of house missing rsp4 clips throughout, second floor window with 2x8 header right side of house calls for 2-2x6T. |
| 05/30/2024 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Passed |
|