Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-COM-0824-01656
Permit Details
Apply Date:
08/23/2024
Applicant:
Gary Wellborn
Description:
The interior scope of work entails interior tenant improvement of 18,625 SF of existing office to be converted to a laboratory use. The laboratory use is for testing and is not a chemical laboratory space with hazardous chemical storage. New laboratory will include testing chambers, small bridge cranes, and other owner supplied equipment. Exterior work includes installation of a LN2 tank, associated concrete pad, and a 780 SF canopy structure. The new canopy is an extension of the existing canopy and will be added at southeast corner of building.
Permit Reviews
Permit Number - TC-COM-0824-01656
Permit Status: Inspections
Permit Description: The interior scope of work entails interior tenant improvement of 18,625 SF of existing office to be converted to a laboratory use. The laboratory use is for testing and is not a chemical laboratory space with hazardous chemical storage. New laboratory will include testing chambers, small bridge cranes, and other owner supplied equipment. Exterior work includes installation of a LN2 tank, associated concrete pad, and a 780 SF canopy structure. The new canopy is an extension of the existing canopy and will be added at southeast corner of building.
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
08/27/2024 | COMMERCIAL REVIEW - FULL v.1 | 09/26/2024 | REQUIRES RESUBMIT |
11/18/2024 | RESTAMP - COMMERCIAL v.1 | 11/21/2024 | APPROVED |
10/16/2024 | COMMERCIAL REVIEW - FULL v.2 | 10/22/2024 | REQUIRES RESUBMIT |
11/08/2024 | COMMERCIAL REVIEW - FULL v.3 | 11/18/2024 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-COM-0824-01656
Permit Status: Inspections
Permit Description: The interior scope of work entails interior tenant improvement of 18,625 SF of existing office to be converted to a laboratory use. The laboratory use is for testing and is not a chemical laboratory space with hazardous chemical storage. New laboratory will include testing chambers, small bridge cranes, and other owner supplied equipment. Exterior work includes installation of a LN2 tank, associated concrete pad, and a 780 SF canopy structure. The new canopy is an extension of the existing canopy and will be added at southeast corner of building.
Total Outstanding Activity Conditions - 13
Date | Name |
---|---|
11/18/2024 | AIR BALANCING REPORT IS REQUIRED. |
11/18/2024 | SPECIAL INSPECTION FOR BOLTS INSTALLED IN CONCRETE IS REQUIRED. |
11/18/2024 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. |
11/18/2024 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
11/18/2024 | SPECIAL INSPECTION FOR EXPANSION ANCHORS IS REQUIRED. |
11/18/2024 | SPECIAL INSPECTION FOR FIELD WELDING IS REQUIRED. |
11/18/2024 | SPECIAL INSPECTION FOR HIGH STRENGTH BOLTING IS REQUIRED. |
11/18/2024 | Masonry Inspection Report submittal review is required. |
11/18/2024 | Post-Installed Anchor Inspection Report is required. |
11/18/2024 | SPECIAL INSPECTION FOR REINFORCING STEEL AND/OR PRE-STRESSING TENDONS IS REQUIRED. |
11/18/2024 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. |
11/18/2024 | SPECIAL INSPECTION FOR STRUCTURAL MASONRY IS REQUIRED. |
11/18/2024 | WATER STERILIZATION REPORT IS REQUIRED. |
Conditions
Permit Number - TC-COM-0824-01656
Permit Status: Inspections
Permit Description: The interior scope of work entails interior tenant improvement of 18,625 SF of existing office to be converted to a laboratory use. The laboratory use is for testing and is not a chemical laboratory space with hazardous chemical storage. New laboratory will include testing chambers, small bridge cranes, and other owner supplied equipment. Exterior work includes installation of a LN2 tank, associated concrete pad, and a 780 SF canopy structure. The new canopy is an extension of the existing canopy and will be added at southeast corner of building.
Date | Description | Comments |
---|---|---|
08/27/2024 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. | |
11/19/2024 | A Special Inspections Intermediate Certificate must be submitted and reviewed prior to issuance of this permit. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-COM-0824-01656
Permite Description: The interior scope of work entails interior tenant improvement of 18,625 SF of existing office to be converted to a laboratory use. The laboratory use is for testing and is not a chemical laboratory space with hazardous chemical storage. New laboratory will include testing chambers, small bridge cranes, and other owner supplied equipment. Exterior work includes installation of a LN2 tank, associated concrete pad, and a 780 SF canopy structure. The new canopy is an extension of the existing canopy and will be added at southeast corner of building.
Total Outstanding Inspections - 1
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/29/2024 | COT - HCBU - Framing | N/A | Partial Pass | 11/29/24: framing per plan at perimeter walls at rooms 101,102,112,107,106. Pending east walls. Ok to insulate and drywall. |