Start Date Submittal Complete Date Status  
07/05/2023 COMMERCIAL REVIEW - FULL v.2 07/14/2023 REQUIRES RESUBMIT Review Details
05/26/2023 COMMERCIAL REVIEW - FULL v.1 06/27/2023 REQUIRES RESUBMIT Review Details
07/24/2023 COMMERCIAL REVIEW - FULL v.3 07/24/2023 APPROVED Review Details
04/02/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.1 04/04/2024 APPROVED Review Details
07/24/2023 RESTAMP - COMMERCIAL v.1 07/25/2023 APPROVED Review Details

Conditions

Permit Number - TC-COM-0523-01387
Permit Status: Complete
Permit Description: Interior Remodel Botanica Warehouse
Date Description Comments
04/02/2024 AIR BALANCING REPORT IS REQUIRED.
07/07/2023 Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit.
04/02/2024 WATER STERILIZATION REPORT IS REQUIRED.

Completed Inspections

Permit Status: Complete
Permit Number: TC-COM-0523-01387
Permit Description: Interior Remodel Botanica Warehouse
Total Completed Inspections - 20
Date Description Inspector Results Comments
08/09/2023 COT - HCBU - Framing Passed
08/09/2023 COT - HCPL - Plumbing Intermediate Passed
08/09/2023 COT - HCEL - Electrical Above Ceiling Passed
08/09/2023 COT - HCEL - Electrical Intermediate Passed
10/19/2023 COT - HCPL - Plumbing Progress Passed Gas pressure test.
11/13/2023 COT - HCPL - Plumbing Above Ceiling Passed 11/13/23: plumbing above ceiling passed. Ok to proceed
12/08/2023 COT - HCME - Mechanical Progress Passed 12/8/2023. Mechanical above ceiling in warehouse approved. Corrections were made.
01/17/2024 COT - HCPL - Yard Water Line Passed
02/05/2024 COT - HCEL - Electrical Progress Passed Electrical rough-in is complete, light fixtures are installed in grid ceiling and properly wired to structural members, and all wiring is ran to electrical panel waiting on TEP Connection from transformer. Okay to install grid ceiling tiles.
02/05/2024 COT - HCME - Mechanical Intermediate Passed Mechanical rough-in is complete, trim out of registers in grid ceiling is complete, thermostats are installed on walls, and all ductwork is properly supported in plenum.
02/05/2024 COT - HCBU - Building Progress Passed 2/5/24: Inspection is for main water line from meter to back flow preventer and then to building water supply line. Okay to shade pipes and backfill trench, and to wrap pipes with insulation to prevent pipes from freezing.
02/05/2024 BULD - Electrical Clearance Passed Sweep and conduit is installed on electrical panel, trench is properly dug from building to transformer pad, and ground wires are properly installed. Okay to energize system. ECO Clearance issued for new panel and meter box.
02/05/2024 COT - BULD - SWG Clearance Passed Gas meter is placed. Okay to re-connect gas to building. SWG Clearance issued.
03/26/2024 COT - FCON - Fire - Final Passed
03/26/2024 ENGR Engineering Final Passed
03/26/2024 TRSP - ROW - Final/Close-Out Passed
04/03/2024 COT - HCBU - Building Final Passed Corrections were made. Air and balance report and chlorination report uploaded and are under review in the portal. 4/3/2024
04/03/2024 COT - HCPL - Plumbing Final Passed Corrections were made. Air and balance report and chlorination report uploaded and are under review in the portal. 4/3/2024
04/03/2024 COT - HCME - Mechanical Final Passed Corrections were made. Air and balance report uploaded and are under review in the portal. 4/3/2024
04/03/2024 COT - HCEL - Electrical Final Passed

Documents

File Name Document Type  
COFO_FINALCOFO_COMMERCIAL.PDF DOCUMENTS VIEW
BOTANICAWAREHOUSEBALANCE REPORT_V1.PDF DOCUMENTS VIEW
CATALINA MECH. - BOTANICAL KITCHEN - WAREHOUSE LAB RESULTS-2024-04-01_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
2_A-1 THRU E3.0 2902 N EL BURRITO AVE- 7-24-23 - COPY_V1.PDF DOCUMENTS VIEW
23001 WAREHOUSE MECH CHECK_V1.PDF DOCUMENTS VIEW
23001 WAREHOUSE SYSTEM DESIGN REPORT_V1.PDF DOCUMENTS VIEW
AMERIKOOLER ARCHITECTURAL SPECIFICATIONS_2019_V1.PDF DOCUMENTS VIEW
CONS-1_A-1 THRU E3.0 2902 N EL BURRITO AVE- 5-25-23_V1.PDF DOCUMENTS VIEW
TURBO_AIR_BOTANICA_CONDENSER_TS025MR404A2A-T_V1.PDF DOCUMENTS VIEW
TURBO_AIR_EVAP_1-17-23_V1.PDF DOCUMENTS VIEW
CONS-1_A-1 THRU E3.0 2902 N EL BURRITO AVE- 5-25-23_V1.PDF DOCUMENTS VIEW
23001 WAREHOUSE SYSTEM DESIGN REPORT_V1.PDF DOCUMENTS VIEW
23001 WAREHOUSE MECH CHECK_V1.PDF DOCUMENTS VIEW