Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0523-01387
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/27/2023 | Water - PDSD | APPROVED | |||
| 06/27/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/05/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Activity Number: TC-COM-0523-01387 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. Structural(S) Reviewer Andrew Bevis abevis@safebuilt.com Approved Reason: Date Completed : 6/5/2023 4:27:28 PM 1. No structural work being completed. Approved. Building(B) Reviewer Andrew Bevis abevis@safebuilt.com Denied Reason: Date Completed : 6/5/2023 4:26:25 PM 1. General: Provide all manufacturer specification for the walk in coolers. 2. General: Provide clarification about the adjacent tenant and any required separations that may need to be required. Are they considered separate buildings in accordance with 2018 IBC Section 503.1, or is it considered a nonseparated/separated mix use. Provide all clarification as to all applicable requirements of Sections 508.3 and 508.4. Mechanical(M) Reviewer Andrew Bevis abevis@safebuilt.com Denied Reason: Date Completed : 6/5/2023 4:26:47 PM 1. Sheet M1: The structure shares a common wall with the adjoining structure. On the south wall of the building there are two outside air intakes. Ensure that these intakes meet the applicable separation requirements from other exhaust outlets in accordance with 2018 IMC Section 501.3.1. 2. Sheet M1: The bathroom exhaust appears that it may exhaust within 3' of an operable opening. Provide clarification that the exhaust meets the applicable separation requirements in accordance with 2018 IMC Section 501.3.1. Electrical(E) Reviewer Andrew Bevis abevis@safebuilt.com Approved Reason: Date Completed : 6/5/2023 4:26:33 PM Plumbing(P) Reviewer Andrew Bevis abevis@safebuilt.com Approved Reason: Date Completed : 6/5/2023 4:26:58 PM |
||
| 06/13/2023 | Site Engineering | REQUIRES RESUBMIT | See zoning comment | ||
| 06/06/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-COM-0523-01387 2902 N El Burrito Av. I-1 Interior Remodel Botanical Warehouse (1st Review) TRANSMITTAL DATE: ‎June 06, 2023 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in I-1 zone (UDC 4.7.29), Commercial Storage is an allowed use in the zone (UDC Table 4.8-5), subject to Use Specific Standards 4.9.10.A and 4.9.13.Q. 1. Clarify what the use is. If the proposed use is within the Retail Trade Use Group having anything to do with marijuana provide a copy of an approved Marijuana Use Authorization Letter with the next submittal. 2. Indicate clearly on the plans that the two sites are operating independently of each other on the next submittal. If you have any questions about this transmittal, please contact Nicholas Ross at Nicholas.Ross@tucsonaz.gov. |
||
| 06/12/2023 | Fire New Construction | REVIEW COMPLETED | |||
| 05/26/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |