Permit Details

Status:
Issued
Type:
Commercial Building
Address NEW:
1046 E BROADWAY BL
Apply Date:
02/16/2024
Applicant:
Annette Suarez
Description:
Change from auto shop to retail location.

Permit Reviews

Permit Number - TC-COM-0224-00312
Permit Status: Issued
Permit Description: Change from auto shop to retail location.
Start Date Submittal Complete Date Status  
03/04/2025 COMMERCIAL REVIEW - LIMITED v.5 04/03/2025 REQUIRES RESUBMIT Review Details
02/16/2024 COMMERCIAL REVIEW - LIMITED v.1 02/16/2024 REQUIRES RESUBMIT Review Details
12/03/2025 ADMINISTRATIVE v.2 12/03/2025 APPROVED Review Details
11/20/2025 RESTAMP - COMMERCIAL v.1 11/25/2025 APPROVED Review Details
02/05/2025 COMMERCIAL REVIEW - LIMITED v.4 02/21/2025 REQUIRES RESUBMIT Review Details
11/05/2025 COMMERCIAL REVIEW - LIMITED v.6 11/20/2025 APPROVED Review Details
09/12/2024 COMMERCIAL REVIEW - LIMITED v.3 09/26/2024 REQUIRES RESUBMIT Review Details
03/05/2026 BUILDING DEFERRED SUBMITTAL REVIEW v.1 03/06/2026 APPROVED Review Details
11/25/2025 ADMINISTRATIVE v.1 11/25/2025 REQUIRES RESUBMIT Review Details
04/02/2024 COMMERCIAL REVIEW - LIMITED v.2 04/17/2024 REQUIRES RESUBMIT Review Details

Conditions

Permit Number - TC-COM-0224-00312
Permit Status: Issued
Permit Description: Change from auto shop to retail location.
Date Description Comments
03/18/2025 AIR BALANCING REPORT IS REQUIRED.
11/19/2025 Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact.
02/05/2025 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900.
03/18/2025 WATER STERILIZATION REPORT IS REQUIRED.

Outstanding Inspections

Permit Status: Issued
Permit Number: TC-COM-0224-00312
Permite Description: Change from auto shop to retail location.
Total Outstanding Inspections - 9
Last Inspection Date Description Inspector Results Comments
02/24/2026 BULD - Electrical Clearance N/A Not Applicable
02/24/2026 COT - BULD - SWG Clearance N/A Not Applicable
02/24/2026 COT - LCBU - Preslab N/A Not Applicable
02/24/2026 COT - LCPL - Rough Soil N/A Not Applicable
03/12/2026 COT - LCBU - Building Final N/A Re-inspection required 3/12/26: ensure all j-boxes and open knock outs at j-boxes are sealed, drinking fountain shall be no higher than 36" above finish floor to spout outlet, grab bars in restroom do not meet A117.1 requirements (36" bar required behind water closet, location of vertical grab bar), bathroom lav above the max 34" above finish floor, mirror shall not be higher than 40" to reflective surface, water heater must be insulated. Signage for restrooms required
03/12/2026 COT - LCEL - Outdoor Lighting N/A Re-inspection required 3/12/26: ensure all j-boxes and open knock outs at j-boxes are sealed, drinking fountain shall be no higher than 36" above finish floor to spout outlet, grab bars in restroom do not meet A117.1 requirements (36" bar required behind water closet, location of vertical grab bar), bathroom lav above the max 34" above finish floor, mirror shall not be higher than 40" to reflective surface, water heater must be insulated.
03/12/2026 ENGR Engineering Final N/A Re-inspection required Landing at entrance door needs to be 60" x 60". Ramp into building is 20% slope, maximum allowed without handrails is 5%. No ADA parking sign, need sign indicating van accessible handicapped parking. Landscape incomplete, missing plants.
03/12/2026 COT - LCPL - Plumbing Final N/A Re-inspection required 3/12/26: ensure all j-boxes and open knock outs at j-boxes are sealed, drinking fountain shall be no higher than 36" above finish floor to spout outlet, grab bars in restroom do not meet A117.1 requirements (36" bar required behind water closet, location of vertical grab bar), bathroom lav above the max 34" above finish floor, mirror shall not be higher than 40" to reflective surface, water heater must be insulated. Signage for restrooms required
03/12/2026 COT - LCEL - Electrical Final N/A Re-inspection required 3/12/26: ensure all j-boxes and open knock outs at j-boxes are sealed, drinking fountain shall be no higher than 36" above finish floor to spout outlet, grab bars in restroom do not meet A117.1 requirements (36" bar required behind water closet, location of vertical grab bar), bathroom lav above the max 34" above finish floor, mirror shall not be higher than 40" to reflective surface, water heater must be insulated.

Completed Inspections

Permit Status: Issued
Permit Number: TC-COM-0224-00312
Permit Description: Change from auto shop to retail location.
Total Completed Inspections - 7
Date Description Inspector Results Comments
02/06/2026 COT - LCPL - Plumbing Intermediate Passed
02/06/2026 COT - LCME - Mechanical Intermediate Passed Ok to insulate and cover walls.
02/06/2026 COT - LCEL - Electrical Above Ceiling Passed
02/06/2026 COT - LCBU - Framing Passed OK to insulate and sheet rock,walls.
02/27/2026 COT - LCEL - Electrical Intermediate Passed New restroom complete.
03/12/2026 COT - LCME - Mechanical Final Passed
03/12/2026 COT - FCON - Fire - Final Passed

Documents

File Name Document Type  
1046 E BROADWAY BL COMPACTION REPORT_V1.PDF DOCUMENTS VIEW
WATER LAB TEST-2026-03-04_V1.PDF DOCUMENTS VIEW
WILCATSMOKE AIR REPORT_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW
CONS-4_PLAN SET_V5.PDF DOCUMENTS VIEW