Permit: TC-COM-0224-00312
Permit Details
Status:
Issued
Type:
Commercial Building
Address:
1046 E BROADWAY BL
Address NEW:
1046 E BROADWAY BL
Apply Date:
02/16/2024
Applicant:
Annette Suarez
Description:
Change from auto shop to retail location.
Permit Reviews
Permit Number - TC-COM-0224-00312
Permit Status: Issued
Permit Description: Change from auto shop to retail location.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/04/2025 | COMMERCIAL REVIEW - LIMITED v.5 | 04/03/2025 | REQUIRES RESUBMIT |
| 02/16/2024 | COMMERCIAL REVIEW - LIMITED v.1 | 02/16/2024 | REQUIRES RESUBMIT |
| 12/03/2025 | ADMINISTRATIVE v.2 | 12/03/2025 | APPROVED |
| 11/20/2025 | RESTAMP - COMMERCIAL v.1 | 11/25/2025 | APPROVED |
| 02/05/2025 | COMMERCIAL REVIEW - LIMITED v.4 | 02/21/2025 | REQUIRES RESUBMIT |
| 11/05/2025 | COMMERCIAL REVIEW - LIMITED v.6 | 11/20/2025 | APPROVED |
| 09/12/2024 | COMMERCIAL REVIEW - LIMITED v.3 | 09/26/2024 | REQUIRES RESUBMIT |
| 03/05/2026 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 03/06/2026 | APPROVED |
| 11/25/2025 | ADMINISTRATIVE v.1 | 11/25/2025 | REQUIRES RESUBMIT |
| 04/02/2024 | COMMERCIAL REVIEW - LIMITED v.2 | 04/17/2024 | REQUIRES RESUBMIT |
Conditions
Permit Number - TC-COM-0224-00312
Permit Status: Issued
Permit Description: Change from auto shop to retail location.
| Date | Description | Comments |
|---|---|---|
| 03/18/2025 | AIR BALANCING REPORT IS REQUIRED. | |
| 11/19/2025 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. | |
| 02/05/2025 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. | |
| 03/18/2025 | WATER STERILIZATION REPORT IS REQUIRED. |
Outstanding Inspections
Permit Status: Issued
Permit Number: TC-COM-0224-00312
Permite Description: Change from auto shop to retail location.
Total Outstanding Inspections - 9
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/24/2026 | BULD - Electrical Clearance | N/A | Not Applicable | |
| 02/24/2026 | COT - BULD - SWG Clearance | N/A | Not Applicable | |
| 02/24/2026 | COT - LCBU - Preslab | N/A | Not Applicable | |
| 02/24/2026 | COT - LCPL - Rough Soil | N/A | Not Applicable | |
| 03/12/2026 | COT - LCBU - Building Final | N/A | Re-inspection required | 3/12/26: ensure all j-boxes and open knock outs at j-boxes are sealed, drinking fountain shall be no higher than 36" above finish floor to spout outlet, grab bars in restroom do not meet A117.1 requirements (36" bar required behind water closet, location of vertical grab bar), bathroom lav above the max 34" above finish floor, mirror shall not be higher than 40" to reflective surface, water heater must be insulated. Signage for restrooms required |
| 03/12/2026 | COT - LCEL - Outdoor Lighting | N/A | Re-inspection required | 3/12/26: ensure all j-boxes and open knock outs at j-boxes are sealed, drinking fountain shall be no higher than 36" above finish floor to spout outlet, grab bars in restroom do not meet A117.1 requirements (36" bar required behind water closet, location of vertical grab bar), bathroom lav above the max 34" above finish floor, mirror shall not be higher than 40" to reflective surface, water heater must be insulated. |
| 03/12/2026 | ENGR Engineering Final | N/A | Re-inspection required | Landing at entrance door needs to be 60" x 60". Ramp into building is 20% slope, maximum allowed without handrails is 5%. No ADA parking sign, need sign indicating van accessible handicapped parking. Landscape incomplete, missing plants. |
| 03/12/2026 | COT - LCPL - Plumbing Final | N/A | Re-inspection required | 3/12/26: ensure all j-boxes and open knock outs at j-boxes are sealed, drinking fountain shall be no higher than 36" above finish floor to spout outlet, grab bars in restroom do not meet A117.1 requirements (36" bar required behind water closet, location of vertical grab bar), bathroom lav above the max 34" above finish floor, mirror shall not be higher than 40" to reflective surface, water heater must be insulated. Signage for restrooms required |
| 03/12/2026 | COT - LCEL - Electrical Final | N/A | Re-inspection required | 3/12/26: ensure all j-boxes and open knock outs at j-boxes are sealed, drinking fountain shall be no higher than 36" above finish floor to spout outlet, grab bars in restroom do not meet A117.1 requirements (36" bar required behind water closet, location of vertical grab bar), bathroom lav above the max 34" above finish floor, mirror shall not be higher than 40" to reflective surface, water heater must be insulated. |
Completed Inspections
Permit Status: Issued
Permit Number: TC-COM-0224-00312
Permit Description: Change from auto shop to retail location.
Total Completed Inspections - 7
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/06/2026 | COT - LCPL - Plumbing Intermediate | Passed | ||
| 02/06/2026 | COT - LCME - Mechanical Intermediate | Passed | Ok to insulate and cover walls. | |
| 02/06/2026 | COT - LCEL - Electrical Above Ceiling | Passed | ||
| 02/06/2026 | COT - LCBU - Framing | Passed | OK to insulate and sheet rock,walls. | |
| 02/27/2026 | COT - LCEL - Electrical Intermediate | Passed | New restroom complete. | |
| 03/12/2026 | COT - LCME - Mechanical Final | Passed | ||
| 03/12/2026 | COT - FCON - Fire - Final | Passed |