Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 12412005A


Addresses:

1046 E BROADWAY BL


Inspection Status: Re-inspection required

Inspection History: COT - LCBU - Building Final 

Permit Number - TC-COM-0224-00312

Inspection Description - COT - LCBU - Building Final 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
03/12/2026 COT - LCBU - Building Final  Re-inspection required 3/12/26: ensure all j-boxes and open knock outs at j-boxes are sealed, drinking fountain shall be no higher than 36" above finish floor to spout outlet, grab bars in restroom do not meet A117.1 requirements (36" bar required behind water closet, location of vertical grab bar), bathroom lav above the max 34" above finish floor, mirror shall not be higher than 40" to reflective surface, water heater must be insulated. Signage for restrooms required