Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Issued
Type:
Residential Building - One or Two Family
Address:
3020 E 17TH ST
Address NEW:
3020 E 17TH ST
Apply Date:
06/17/2022
Applicant:
EDUARDO SABORI
Description:
R-Master Bedroom & Garage Addition

Permit Reviews

Permit Number - T22CM04532
Permit Status: Issued
Permit Description: R-Master Bedroom & Garage Addition
Start Date Submittal Complete Date Status  
06/17/2022 RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO 07/05/2022 COMPLETED Review Details
04/04/2023 RESIDENTIAL NEW DWELLING v.3 04/07/2023 APPROVED Review Details
12/12/2022 RESIDENTIAL NEW DWELLING v.1 01/13/2023 REQUIRES RESUBMIT Review Details
04/07/2023 RESTAMP - RESIDENTIAL v.1 04/10/2023 APPROVED Review Details
03/03/2023 RESIDENTIAL NEW DWELLING v.2 03/23/2023 REQUIRES RESUBMIT Review Details

Outstanding Activity Conditions

Permit Number - T22CM04532
Permit Status: Issued
Permit Description: R-Master Bedroom & Garage Addition
Total Outstanding Activity Conditions - 2
Date Name
03/23/2023 Manual J must be submitted and approved prior to Mechanical Final..
03/23/2023 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Conditions

Permit Number - T22CM04532
Permit Status: Issued
Permit Description: R-Master Bedroom & Garage Addition
Date Description Comments
04/07/2023 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/integrated-planning/PDSD/PDSD_Owner_Builder_Affidavit.pdf, is required prior to issuance of permit.

Outstanding Inspections

Permit Status: Issued
Permit Number: T22CM04532
Permite Description: R-Master Bedroom & Garage Addition
Total Outstanding Inspections - 14
Last Inspection Date Description Inspector Results Comments
05/12/2023 COT - RSBU - Excavation/Rebar/Zoning N/A Re-inspection required 5-12-23: 1-Setbacks are not according to approved plans. 2-Footings are not 12" below undisturbed soil. 3-Sleeve piping in footings. 4- Install Hold downs per plans.
05/12/2023 COT - RSBU - Preslab N/A Re-inspection required 5-12-23: 1-Setbacks are not according to approved plans. 2-Footings are not 12" below undisturbed soil. 3-Sleeve piping in footings. 4- Install Hold downs per plans.
05/12/2023 COT - RSPL - Yard Water Line N/A Re-inspection required 5-12-23: Tied into existing lateral. 1-Need tracer wire on exterior piping.
05/12/2023 COT - RSPL - Sewer N/A Partial Pass 5-12-23: Tied into existing lateral. 1-Need tracer wire on exterior piping; ok inside footprint.
06/21/2023 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing N/A Re-inspection required
02/07/2024 COT - BULD - SWG Clearance N/A Not Applicable
02/07/2024 BULD - Electrical Clearance N/A Not Applicable
06/21/2023 COT - RSBU - Interior Shear Bracing N/A Not Ready
02/07/2024 COT - RSEL - Electrical Underground N/A Not Applicable
02/07/2024 COT - RSEL - Grounding/Bonding N/A Not Applicable
02/07/2024 COT - RSEL - Outdoor Lighting N/A Re-inspection required 2/7/24: exterior receptacles must be WR, Arc-fault breaker's missing at panel (multiple locations missing), sediment trap at water heater missing, sediment trap at A/C unit not properly installed, pipes on exterior must be coated for UV protection, water lines at water heater must be properly insulated and wrapped for if protection, hose bibs must have vacuum breaker, handrails at stair way not per code, drain at bathroom lavatory must be smooth interior, receptacle on south west corner of garage not on same GFCI circuit as garage receptacles. Properly secure A/C whip and thermostat whip, AC is being over Amped (max 25).
02/07/2024 RSBU - Building Final N/A Re-inspection required 2/7/24: exterior receptacles must be WR, Arc-fault breaker's missing at panel (multiple locations missing), sediment trap at water heater missing, sediment trap at A/C unit not properly installed, pipes on exterior must be coated for UV protection, water lines at water heater must be properly insulated and wrapped for if protection, hose bibs must have vacuum breaker, handrails at stair way not per code, drain at bathroom lavatory must be smooth interior, receptacle on south west corner of garage not on same GFCI circuit as garage receptacles. Properly secure A/C whip and thermostat whip, AC is being over Amped (max 25).
02/07/2024 COT - RSPL - Plumbing Final N/A Re-inspection required 2/7/24: exterior receptacles must be WR, Arc-fault breaker's missing at panel (multiple locations missing), sediment trap at water heater missing, sediment trap at A/C unit not properly installed, pipes on exterior must be coated for UV protection, water lines at water heater must be properly insulated and wrapped for if protection, hose bibs must have vacuum breaker, handrails at stair way not per code, drain at bathroom lavatory must be smooth interior, receptacle on south west corner of garage not on same GFCI circuit as garage receptacles. Properly secure A/C whip and thermostat whip, AC is being over Amped (max 25).
02/07/2024 COT - RSME - Mechanical Final N/A Re-inspection required 2/7/24: exterior receptacles must be WR, Arc-fault breaker's missing at panel (multiple locations missing), sediment trap at water heater missing, sediment trap at A/C unit not properly installed, pipes on exterior must be coated for UV protection, water lines at water heater must be properly insulated and wrapped for if protection, hose bibs must have vacuum breaker, handrails at stair way not per code, drain at bathroom lavatory must be smooth interior, receptacle on south west corner of garage not on same GFCI circuit as garage receptacles. Properly secure A/C whip and thermostat whip, AC is being over Amped (max 25).

Completed Inspections

Permit Status: Issued
Permit Number: T22CM04532
Permit Description: R-Master Bedroom & Garage Addition
Total Completed Inspections - 13
Date Description Inspector Results Comments
05/12/2023 COT - RSPL - Rough Soil Passed
05/17/2023 COT - RSBU - Excavation/Rebar/Zoning Passed Footings have been dug to 12" deep. Sleeves have been installed where sewer line crosses footing. Shear wall hold downs have been installed per plans. Rebar mat needs to be supported with dobies to keep it off of subsoil.
05/17/2023 COT - RSBU - Preslab Passed Rebar mat is in place, needs dobies to keep it off of subsoil. Compaction is complete. Okay to pour concrete slab.
05/17/2023 COT - RSPL - Yard Water Line Passed 5-17-23: Tracer wire has been added around sewer pipe and waterline. Sleeves have been added where sewer and water line cross footing.
05/17/2023 COT - RSPL - Sewer Passed 5-17-23: Tracer wire has been added around sewer pipe. Sleeves have been added where sewer and water line cross footing.
06/21/2023 COT - RSBU - Roof Nailing Passed
09/12/2023 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed
09/12/2023 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed
02/07/2024 COT - RSBU - Interior Shear Bracing Passed
03/28/2024 RSBU - Building Final Passed
03/28/2024 COT - RSPL - Plumbing Final Passed
03/28/2024 COT - RSME - Mechanical Final Passed
03/28/2024 COT - RSEL - Electrical Final Passed

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
T22CM04532 OBA_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
3020 E 17 ST CORRECTED 20-FEB-2023 13-44-05(1)_V1.PDF DOCUMENTS VIEW
APPLICATION_V1.PDF DOCUMENTS VIEW
3020 E 17 ST CORRECTED 20-FEB-2023 13-44-05(1)_V1.PDF DOCUMENTS VIEW