Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T18CM02368
Permit Details
Apply Date:
03/29/2018
Applicant:
METRO TED LISA
Description:
NEW SERVICE BUILDING
Contractors:
- CONCORD GENERAL CONTRACTING INC
Permit Reviews
Permit Number - T18CM02368
Permit Status: C of o
Permit Description: NEW SERVICE BUILDING
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
03/29/2018 | COMMERCIAL - NEW | 04/03/2018 | COMPLETED |
04/03/2018 | COMMERCIAL - NEW | 05/18/2018 | COMPLETED |
05/18/2018 | RESUBMITTAL - TI ALL | 06/19/2018 | COMPLETED |
06/19/2018 | RESUBMITTAL | 06/26/2018 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T18CM02368
Permit Status: C of o
Permit Description: NEW SERVICE BUILDING
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
03/29/2018 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T18CM02368
Permit Description: NEW SERVICE BUILDING
Total Completed Inspections - 36
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/19/2018 | MECHANICAL - FINAL | RSHERRY | Approved | AIR BALANCE REPORT REQUIRED |
06/19/2018 | PLUMBING - FINAL | RSHERRY | Approved | WATER CHLORINATION REPORT REQUIRED |
10/10/2018 | PLUMBING - ROUGH, SOIL | JBURGE | Approved | Waste and vent lines at 1 1/2" - 4". Ok to cover ( under test). |
11/06/2018 | BUILDING PRE-SLAB | JBURGE | Approved | Slab #4. Ok to place concrete. |
11/06/2018 | EXCAVATION/LAYOUT REBAR & ZON | JBURGE | Approved | Slab #4, footings and slab. Ok to place concrete. |
11/30/2018 | REINFORCED MASONRY PRE-GROUT | JBURGE | Approved | Interior walls at 8'-10'; Exterior walls at 8'-10', GL:B/2.5-5, 5/A-B, A/2.5-5. Walls at 8'-12': GL, 2.25/A-B, 1/A-B, A/1-2.5, B/1-2.5. OK to grout progress areas. |
12/07/2018 | ELECTRIC - UNDERGROUND | DMUNIZ | Approved | In front of the north side of the building |
01/31/2019 | PLUMBING - GAS PRESSURE TEST | JBURGE | Approved | Gas pressure test for both buildings. Not ready to set meters |
01/31/2019 | FRAMING | JBURGE | Approved | |
02/14/2019 | PLUMBING - PROGRESS | RCHANDLER | Approved | DWV for floor drains in back and water lines |
03/01/2019 | TEP CLEARANCE - PM | TVALENCIAR | Approved | CLEAR ECO |
03/01/2019 | ELECTRIC - SERVICE UPGRADE | TVALENCIAR | Approved | Clear electric ECO |
04/01/2019 | MECHANICAL - ABOVE CEILING | RCHANDLER | Approved | |
04/01/2019 | PLUMBING - ABOVE CEILING | RCHANDLER | Approved | |
04/01/2019 | ELECTRIC - ABOVE CEILING | RCHANDLER | Approved | |
04/01/2019 | ELECTRIC - CONSTRUCTION POWER | RCHANDLER | Approved | |
04/01/2019 | ELECTRIC - TEMPORARY SERVICE | RCHANDLER | Approved | |
04/01/2019 | ELECTRIC - UFER | RCHANDLER | Approved | |
04/01/2019 | ROOF NAILING | RCHANDLER | Approved | |
04/01/2019 | STEM WALL/RETAINING WALL | RCHANDLER | Approved | |
04/11/2019 | MECHANICAL - INTERMEDIATE | TVALENCIA | Approved | |
04/11/2019 | PLUMBING - INTERMEDIATE | TVALENCIA | Approved | |
04/11/2019 | ELECTRIC - FINAL | TVALENCIA | Approved | |
04/11/2019 | ELECTRIC - OUTDOOR LIGHTING | TVALENCIA | Approved | 1-Shall provide special inspection report for the Outdoor Lighting |
04/11/2019 | BUILDING - PROGRESS | TVALENCIA | Approved | |
04/12/2019 | ELECTRIC - PROGRESS | JBURGE | Approved | |
04/12/2019 | BUILDING ABOVE CEILING | JBURGE | Approved | |
04/17/2019 | ELECTRIC - INTERMEDIATE | JBURGE | Approved | |
04/18/2019 | PLUMBING - YARD WTR LINE/TEST | RCHANDLER | Approved | Observed pressure test |
04/24/2019 | SITE - SEWER | TVALENCIA | Approved | |
05/02/2019 | BUILDING - FINAL | TVALENCIA | Approved | 1- Shall provide accessible signage at restrooms. 2- the Mop sink faucet is loose. 3- Shall provide a strap on the floppy conduit for the water heater disconnect. 4- Shall provide locking caps for the condenser refrigeration service ports. 5- Shall seal piping penetrations at east exterior wall. Note; recommend temp C of O. |
05/03/2019 | FIRE - FINAL | jvincent | Approved | will mount bldg # |
05/03/2019 | FIRE SPKLR - FINAL | jvincent | Approved | approved per CB |
03/11/2020 | CERTIFICATE OF OCCUPANCY | DQUINN | Approved | |
03/11/2020 | OUTDOOR LIGHTING FINAL | rmccoy | Approved | |
03/11/2020 | ENGINEERING - FINAL | DROBERTS | Approved |