Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Address NEW:
7119 E BROADWAY BL
Apply Date:
08/09/2011
Applicant:
INTERTECH ARCHITECTS
Description:
TI: MEDICAL OFFICE
Contractors:
  • PARKWAY CONSTRUCTION AND ASSOCIATES L P

Permit Reviews

Permit Number - T11CM02486
Permit Status: C of o
Permit Description: TI: MEDICAL OFFICE
Start Date Submittal Complete Date Status  
08/09/2011 COMMERCIAL - TI 08/16/2011 COMPLETED Review Details
08/16/2011 COMMERCIAL - TI 08/18/2011 COMPLETED Review Details
08/18/2011 COMMERCIAL - TI 09/15/2011 COMPLETED Review Details
09/15/2011 RESUBMITTAL 10/03/2011 COMPLETED Review Details
10/03/2011 RESUBMITTAL 10/18/2011 COMPLETED Review Details
10/18/2011 RESUBMITTAL 10/28/2011 COMPLETED Review Details
10/28/2011 RESUBMITTAL 10/28/2011 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T11CM02486
Permit Status: C of o
Permit Description: TI: MEDICAL OFFICE
Total Outstanding Activity Conditions - 1
Date Name
08/09/2011 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T11CM02486
Permit Description: TI: MEDICAL OFFICE
Total Completed Inspections - 31
Date Description Inspector Results Comments
11/09/2011 PLUMBING - PRE SLAB BBENEDON Approved IVRS - Inspection :*
11/09/2011 PLUMBING - ROUGH, SOIL BBENEDON Approved IVRS - Inspection :*
11/09/2011 PLUMBING - ROUGH, SOIL BBENEDON Approved IVRS - Inspection :
See detailed listing on site.| 999*
NOT INSTALLED AS ILLUSTRATED:
1) 909.2 ONLY ALLOWS ONE WET VENTED FIXTURE UPSTREAM OF THE DRY VENT
2) CONNECTIONS TO THE HORIZONTAL WET VENTED SECTION NEEDS TO BE HORIZONTAL AS ILLUSTRATED ON THE PLAN
11/18/2011 ELECTRIC - UNDERGROUND RMORENO Approved IVRS - Inspection :*
11/29/2011 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
1) CAST IRON CONDENSATE CONNECTION TO PVC MUST BE DONE WITH A FITTING
2) PURPLE PRIMER IS REQUIRED ON ALL PVC FITTINGS PRIOR TO GLUE
3) HARD LIDS OK TO COVER
11/29/2011 FRAMING JBURGE Approved IVRS - Inspection :*
1) OK TO SHEETROCK
12/02/2011 NPPO - FINAL MRUSSO Approved
12/02/2011 SIGN - FINAL MRUSSO Approved
12/02/2011 LANDSCAPE - FINAL MRUSSO Approved
12/05/2011 RIGHT OF WAY - FINAL P.Whiddon Approved
12/06/2011 ELECTRIC - INTERMEDIATE RMORENO Approved IVRS - Inspection :*
12/12/2011 SHEET ROCK NAILING JBURGE Approved IVRS - Inspection :*
12/20/2011 PLUMBING - GAS PRESS TEST FNL BBENEDON Approved 1) TEST ON EXISTING GAS PIPING OK
2) PROVIDE A STAMPED DRAWING
12/20/2011 PLUMBING - GAS PRESSURE TEST BBENEDON Approved IVRS - Inspection :*
12/20/2011 PLUMBING - ROOF DRAINS BBENEDON Approved IVRS - Inspection :*
12/21/2011 PLUMBING - ABOVE CEILING BBENEDON Approved IVRS - Inspection :*
12/23/2011 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection :*
LEFT GAS CARD
PROVIDE OBD DAMPERS AT DIFFUSERS AS PER PLANS OR A LETTER FROM ENGINNEER
12/23/2011 TEP CLEARANCE - AM DROBEY Approved
12/23/2011 PLUMBING - INTERMEDIATE BBENEDON Approved IVRS - Inspection :*
12/27/2011 ELECTRIC - SERVICE UPGRADE RMORENO Approved IVRS - Inspection :*
12/28/2011 ELECTRIC - ABOVE CEILING RMORENO Approved IVRS - Inspection :*
01/04/2012 BUILDING ABOVE CEILING DWALKER Approved IVRS - Inspection :*
01/05/2012 PLUMBING - PROGRESS BBENEDON Approved IVRS - Inspection :*
01/06/2012 FIRE - FINAL WMOTTO Approved
01/06/2012 FIRE - ALARM FINAL WMOTTO Approved
01/06/2012 FIRE SPKLR - FINAL WMOTTO Approved
01/06/2012 PLUMBING - FINAL BBENEDON Approved IVRS - Inspection :*
01/09/2012 ENGINEERING - FINAL DROBERTS Approved PER INSP COPY
01/10/2012 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :*
01/10/2012 BUILDING - FINAL DWALKER Approved IVRS - Inspection :*
01/10/2012 ELECTRIC - FINAL RMORENO Approved IVRS - Inspection :*

Documents

File Name Document Type  
C OF O_01-11-2012.TIF CERT OF OCC VIEW
001_COVER.TIF CONSTRPLANS VIEW
002_G001.TIF CONSTRPLANS VIEW
003_G101.TIF CONSTRPLANS VIEW
004_G201.TIF CONSTRPLANS VIEW
005_G202.TIF CONSTRPLANS VIEW
006_G203.TIF CONSTRPLANS VIEW
007_D101.TIF CONSTRPLANS VIEW
008_A001.TIF CONSTRPLANS VIEW
009_A002.TIF CONSTRPLANS VIEW
010_A003.TIF CONSTRPLANS VIEW
011_A101.TIF CONSTRPLANS VIEW
012_A102.TIF CONSTRPLANS VIEW
013_A121.TIF CONSTRPLANS VIEW
014_A131.TIF CONSTRPLANS VIEW
015_A402.TIF CONSTRPLANS VIEW
016_A501.TIF CONSTRPLANS VIEW
017_M100.TIF CONSTRPLANS VIEW
018_M200.TIF CONSTRPLANS VIEW
019_M300.TIF CONSTRPLANS VIEW
020_M400.TIF CONSTRPLANS VIEW
021_E001.TIF CONSTRPLANS VIEW
022_E002.TIF CONSTRPLANS VIEW
023_E201.TIF CONSTRPLANS VIEW
024_E301.TIF CONSTRPLANS VIEW
025_E501.TIF CONSTRPLANS VIEW
026_P100.TIF CONSTRPLANS VIEW
027_P200.TIF CONSTRPLANS VIEW
028_P300.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW