Permit: T11CM02486

Parcel: 13322500G


Addresses:

7119 E BROADWAY BL

Inspection Status: Denied

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
11/09/2011 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
NOT INSTALLED AS ILLUSTRATED:
1) 909.2 ONLY ALLOWS ONE WET VENTED FIXTURE UPSTREAM OF THE DRY VENT
2) CONNECTIONS TO THE HORIZONTAL WET VENTED SECTION NEEDS TO BE HORIZONTAL AS ILLUSTRATED ON THE PLAN
11/09/2011 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
11/04/2011 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
1) SINK BRANCHES OK