Permit: T10CM01120
Permit Details
Apply Date:
04/23/2010
Applicant:
N/A
Description:
TI: MEDICAL OFFICE
Contractors:
- BARKER MORRISSEY CONTRACTING INC **C
Permit Reviews
Permit Number - T10CM01120
Permit Status: C of o
Permit Description: TI: MEDICAL OFFICE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/23/2010 | PLANS OK TO SUBMIT - COMM | 05/03/2010 | COMPLETED |
| 05/03/2010 | COMMERCIAL TI | 05/26/2010 | COMPLETED |
| 07/07/2010 | RESUBMITTAL - TI ALL | 08/02/2010 | COMPLETED |
| 08/03/2010 | RESUBMITTAL - TI ALL | 09/13/2010 | COMPLETED |
| 09/13/2010 | RESUBMITTAL | 09/22/2010 | COMPLETED |
| 09/22/2010 | RESUBMITTAL | 09/22/2010 | COMPLETED |
| 09/22/2010 | RESUBMITTAL | 09/27/2010 | COMPLETED |
| 10/12/2010 | REVISION - - 1ST | 10/19/2010 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T10CM01120
Permit Status: C of o
Permit Description: TI: MEDICAL OFFICE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 04/23/2010 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T10CM01120
Permit Description: TI: MEDICAL OFFICE
Total Completed Inspections - 38
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/14/2010 | EXCAVATION/LAYOUT REBAR & ZON | LHANLY | Approved | |
| 10/21/2010 | ELECTRIC - UFER | LHANLY | Approved | |
| 10/21/2010 | BUILDING PRE-SLAB | LHANLY | Approved | |
| 10/27/2010 | EXT METAL CLIPS/EXT SHEATHING | LHANLY | Approved | |
| 10/28/2010 | STUCCO MESH | LHANLY | Approved | |
| 10/28/2010 | ROOF NAILING | LHANLY | Approved | |
| 10/28/2010 | STEM WALL/RETAINING WALL | LHANLY | Approved | |
| 10/28/2010 | REINFORCED MASONRY PRE-GROUT | LHANLY | Approved | |
| 11/01/2010 | FRAMING | LHANLY | Approved | |
| 11/05/2010 | SHEET ROCK NAILING | LHANLY | Approved | IVRS - Inspection :* |
| 11/05/2010 | BUILDING - PROGRESS | LHANLY | Approved | IVRS - Inspection :* |
| 11/08/2010 | TEP CLEARANCE - AM | JWEATHER | Approved | TMPP CLEARED PER R. HOLLANDER |
| 11/19/2010 | BUILDING ABOVE CEILING | LHANLY | Approved | |
| 11/24/2010 | PLUMBING - ABOVE CEILING | RLEDONNE | Approved | IVRS - Inspection :* |
| 11/24/2010 | ELECTRIC - INTERMEDIATE | RHOLLAND | Approved | IVRS - Inspection :* |
| 11/24/2010 | ELECTRIC - PROGRESS | RHOLLAND | Approved | IVRS - Inspection :* |
| 11/29/2010 | ELECTRIC - ABOVE CEILING | RHOLLAND | Approved | IVRS - Inspection :* 1) OK VDV CABLING |
| 12/01/2010 | MECHANICAL - ABOVE CEILING | MRAMBER | Approved | IVRS - Inspection :* |
| 12/01/2010 | MECHANICAL - INTERMEDIATE | MRAMBER | Approved | IVRS - Inspection :* |
| 12/01/2010 | RIGHT OF WAY - FINAL | M.Otero | Approved | |
| 12/01/2010 | OUTDOOR LIGHTING FINAL | RHOLLAND | Approved | IVRS - Inspection :* |
| 12/01/2010 | NPPO - FINAL | JFEMLING | Approved | Approved |
| 12/01/2010 | LANDSCAPE - FINAL | JFEMLING | Approved | Approved |
| 12/01/2010 | SIGN - FINAL | JYBARRA | Approved | no sign at this time |
| 12/02/2010 | FIRE - FINAL | DRamirez | Approved | Approved 12/2/10 |
| 12/06/2010 | MECHANICAL - FINAL | MRAMBER | Approved | IVRS - Inspection :* |
| 12/06/2010 | PLUMBING - FINAL | RLEDONNE | Approved | IVRS - Inspection :* |
| 12/06/2010 | PLUMBING - PROGRESS | RLEDONNE | Approved | IVRS - Inspection :* |
| 12/06/2010 | PLUMBING - PRE SLAB | RLEDONNE | Approved | IVRS - Inspection :* |
| 12/06/2010 | PLUMBING - ROUGH, SOIL | RLEDONNE | Approved | IVRS - Inspection :* |
| 12/10/2010 | ENGINEERING - FINAL | DROBERTS | Approved | ALL PREVIOUS COMMENT HAVE BEEN COMPLETED. |
| 12/10/2010 | BUILDING - FINAL | LHANLY | Approved | |
| 12/10/2010 | PLUMBING - INTERMEDIATE | LHANLY | Approved | |
| 12/10/2010 | ELECTRIC - UNDERGROUND | LHANLY | Approved | |
| 12/10/2010 | ELECTRIC - FINAL | LHANLY | Approved | |
| 12/10/2010 | ELECTRIC - OUTDOOR LIGHTING | LHANLY | Approved | |
| 12/15/2010 | ELECTRIC - SERVICE UPGRADE | LHANLY | Approved | |
| 12/15/2010 | CERTIFICATE OF OCCUPANCY | LHANLY | Approved |