Permit: T09CM01970
Permit Details
Apply Date:
07/23/2009
Applicant:
N/A
Description:
NEW CARWASH
Architects:
- GARCIA DAVID V
Contractors:
- D C O CUSTOM BUILDERS L L C
Permit Reviews
Permit Number - T09CM01970
Permit Status: C of o
Permit Description: NEW CARWASH
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 05/25/2010 | REVISION - - 1ST | 06/02/2010 | COMPLETED |
| 06/02/2010 | REVISION - - 1ST | 06/02/2010 | COMPLETED |
| 06/11/2010 | REVISION - SITE | 06/14/2010 | COMPLETED |
| 06/15/2010 | REVISION - SITE | 06/15/2010 | COMPLETED |
| 07/23/2009 | SITE | 08/14/2009 | COMPLETED |
| 08/14/2009 | SITE | 09/22/2009 | COMPLETED |
| 09/22/2009 | PLANS OK TO SUBMIT - COMM | 09/22/2009 | COMPLETED |
| 09/22/2009 | 3RD PARTY REVIEW-COMMERCIAL | 12/07/2009 | COMPLETED |
| 10/15/2009 | RESUBMITTAL - SITE ALL | 11/06/2009 | COMPLETED |
| 11/12/2009 | RESUBMITTAL - SITE | 11/17/2009 | COMPLETED |
| 12/07/2009 | POST 3RD PARTY REVIEW | 12/10/2009 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T09CM01970
Permit Status: C of o
Permit Description: NEW CARWASH
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 07/23/2009 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T09CM01970
Permit Description: NEW CARWASH
Total Completed Inspections - 32
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/22/2009 | STEM WALL/RETAINING WALL | GDABBS | Approved | IVRS - Inspection :* 1) STEM WALLS-CMU STEM WALLS AND CONCRETE STEM WALLS AT NORTH STORE SALES AREA OK 2) SPECIAL INSPECTION BY BRODERICK ENGINEERING |
| 12/22/2009 | ELECTRIC - UNDERGROUND | RJIROUDE | Approved | IVRS - Inspection :* 1) OK 3/0 UFER |
| 12/22/2009 | REINFORCED MASONRY PRE-GROUT | GDABBS | Approved | IVRS - Inspection :* |
| 12/29/2009 | EXCAVATION/LAYOUT REBAR & ZON | GDABBS | Approved | IVRS - Inspection :* 1) EXTERIOR CONCRETE STEM WALLS AT SOUTH, EAST AND WEST WALLS NORTH OF GRID LINE A UP TO THE SOUTH JAMB BARS FOR OPENING AT TRENCH DRAIN 2) EXTERIOR CONCRETE WALL AT NORTH, EAST AND SOUTH WALLS FROM GRID LINE C TO THE NORTH JAMB BARS FOR THE OPENING AT THE FRENCH DRAIN FROM 0' TO 3' 4" AFFE OK TO POUR 3) SPECIAL INSPECTION BY BRODRICK ENGINEERING |
| 12/29/2009 | PLUMBING - ROUGH, SOIL | RRICH | Approved | 1) WATER TEST FROM BLDG THRU TO EXISTING SEWER CONNECTION OK-PENDING COMBUSTION WASTE AND VENT (SYSTEM) TO BE INSTALLED PER DETAIL 1 ON P-3 FOR VENTING OR IF PLAN IS AN INTERNATIONAL PLUMBING CODE PLAN PROVIDE PETITION OF APPEAL FROM BLDG OFFICIAL 2) CONNNECTION TO EXISTING SEWER MAIN IS LEAKING AND REQUIRES CORRECTION 3) 4" SEWER IS STUBBED OVER TO ? TANKS |
| 12/29/2009 | PLUMBING - YARD WTR LINE/TEST | RRICH | Approved | IVRS - Inspection :* 1) PER RED LINE CHANGE TO 1" FROM METER THRU RPB TO STUB UP 4' FROM BLDG, PENDING CITY APPROVED REVISED PLAN |
| 12/29/2009 | SITE - SEWER | RRICH | Approved | IVRS - Inspection :* |
| 12/29/2009 | PLUMBING - PRE SLAB | RRICH | Approved | IVRS - Inspection :* |
| 04/27/2010 | FRAMING | GDABBS | Approved | IVRS - Inspection :* |
| 04/28/2010 | PLUMBING - ROOF DRAINS | RRICH | Approved | WATER TEST OK-APPROVED |
| 04/29/2010 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection :* |
| 05/11/2010 | BUILDING ABOVE CEILING | GDABBS | Approved | IVRS - Inspection :* |
| 05/11/2010 | TEP CLEARANCE - PM | JWEATHER | Approved | TEC CLEARED PER R. JIROUDEK |
| 05/12/2010 | ROOF NAILING | GDABBS | Approved | IVRS - Inspection :* 1) PAY BOOTH AT WEST END OF MAIN BLDG INCLUDES BUTTON PUNCHING AND #10 SCREWS AND METAL STUD FRAMING OK TO COVER |
| 05/20/2010 | SHEET ROCK NAILING | GDABBS | Approved | IVRS - Inspection :* 1) TICKET BOOTH ON WEST END OK |
| 06/02/2010 | FIRE - FINAL | LTHOMAS | Approved | |
| 06/02/2010 | RIGHT OF WAY - FINAL | PWhiddon | Approved | |
| 06/02/2010 | NPPO - FINAL | JFEMLING | Approved | Approved |
| 06/07/2010 | PLUMBING - FINAL | RRICH | Approved | IVRS - Inspection :* |
| 06/07/2010 | PLUMBING - ABOVE CEILING | RRICH | Approved | IVRS - Inspection :* |
| 06/07/2010 | PLUMBING - INTERMEDIATE | RRICH | Approved | IVRS - Inspection :* |
| 06/10/2010 | ELECTRIC - ABOVE CEILING | RJIROUDE | Approved | IVRS - Inspection :* |
| 06/10/2010 | ELECTRIC - INTERMEDIATE | RJIROUDE | Approved | IVRS - Inspection :* |
| 06/10/2010 | ELECTRIC - UFER | RJIROUDE | Approved | IVRS - Inspection :* |
| 06/14/2010 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* |
| 06/14/2010 | ELECTRIC - FINAL | RHOLLAND | Approved | IVRS - Inspection :* 1) OK ELECTRIC |
| 06/15/2010 | LANDSCAPE - FINAL | JFEMLING | Approved | Approved |
| 06/16/2010 | ENGINEERING - FINAL | JFEMLING | Approved | All items complete. Approved |
| 06/17/2010 | BUILDING PRE-SLAB | LHANLY | Approved | |
| 06/17/2010 | ELECTRIC - TEMP POWER FOR TEST | LHANLY | Approved | |
| 10/19/2010 | SIGN - FINAL | JYBARRA | Approved | THE BB HAS BEEN REMOVED FROM SITE |
| 10/20/2010 | BUILDING - FINAL | AQUIROZ | Approved | DEMO OF BILLBOARD COMPLETE T10BU01460 |