Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
MULTI FAMILY NEW
Apply Date:
02/26/2009
Applicant:
ROBERT GARDNER
Description:
TOWNHOUSE APARTMENT BLDG T07-M0166
Contractors:
  • R W G CONSTRUCTION CO ,

Permit Reviews

Permit Number - T09CM00443
Permit Status: C of o
Permit Description: TOWNHOUSE APARTMENT BLDG T07-M0166
Start Date Submittal Complete Date Status  
02/26/2009 RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU 02/27/2009 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T09CM00443
Permit Status: C of o
Permit Description: TOWNHOUSE APARTMENT BLDG T07-M0166
Total Outstanding Activity Conditions - 1
Date Name
02/26/2009 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T09CM00443
Permit Description: TOWNHOUSE APARTMENT BLDG T07-M0166
Total Completed Inspections - 35
Date Description Inspector Results Comments
03/03/2009 PLUMBING - ROUGH, SOIL WNORTH Approved IVRS - Inspection :*
03/09/2009 ELECTRIC - UNDERGROUND DQUINN Approved IVRS - Inspection :*
03/09/2009 ELECTRIC - UFER DQUINN Approved IVRS - Inspection :*
03/09/2009 BUILDING PRE-SLAB DQUINN Approved IVRS - Inspection :*
03/09/2009 EXCAVATION/LAYOUT REBAR & ZON DQUINN Approved IVRS - Inspection :*
04/24/2009 ROOF NAILING JBURGE Approved IVRS - Inspection :*
TJI SYSTEM; NAILED IN PLACE; PARAPET BEARING WALLS AS PER DETAILS (*)

(*) - #7, 14, 15 (PAGE D1) @ 30" -- OK TO DRY IN PROGRESS AREAS
05/06/2009 EXT METAL CLIPS/EXT SHEATHING JBURGE Approved IVRS - Inspection :*
MOST OF LOWER PORTIONS OF BUILDING HAS BEEN COVERED
UNABLE TO INSPECT HOSE AREAS: STRAPS (HOLD-DOWNS) WERE UNCOVERED ON SHEAR WALLS - OK TO STUCCO MESH PROGRESS AREAS
06/16/2009 STUCCO MESH JBURGE Approved IVRS - Inspection :*
OK TO STUCCO
06/16/2009 BUILDING ABOVE CEILING JBURGE Approved IVRS - Inspection :*
OK TO COVER
06/16/2009 MECHANICAL - ABOVE CEILING JBURGE Approved IVRS - Inspection :*
06/16/2009 MECHANICAL - INTERMEDIATE JBURGE Approved IVRS - Inspection :*
06/17/2009 FRAMING JBURGE Approved IVRS - Inspection :*
OK TO SHEETROCK PENDING
PLUMBING & ELECTRIC INTERMEDIATES
06/19/2009 PLUMBING - ABOVE CEILING BBENEDON Approved IVRS - Inspection :*
06/19/2009 PLUMBING - INTERMEDIATE BBENEDON Approved IVRS - Inspection :*
06/19/2009 ELECTRIC - ABOVE CEILING RJIROUDE Approved IVRS - Inspection :*
06/19/2009 ELECTRIC - INTERMEDIATE RJIROUDE Approved IVRS - Inspection :*
06/30/2009 SHEET ROCK NAILING JBURGE Approved IVRS - Inspection :*
1) UNITS B & C AND GARAGES ARE COMPLETE-ALL UNITS ARE FULLY SPRINKLED-OK TO TAPE THROUGHOUT
11/05/2009 PLUMBING - SEWER HCS CONNECT BBENEDON Approved IVRS - Inspection :*
1) POST YOUR ADDRESS
12/16/2009 PLUMBING - PROGRESS BBENEDON Approved IVRS - Inspection :*
12/21/2009 ELECTRIC - PROGRESS RMORENO Approved IVRS - Inspection :*
12/28/2009 PLUMBING - YARD WTR LINE/TEST RRICH Approved IVRS - Inspection :*
1) WATER OFF
2) TRACER WIRE NOT SECURED
12/29/2009 ENGINEERING - FINAL DROBERTS Approved PERFORMED A FIELD TRIP TO OBTAIN ADDITIONAL INFORMATION AND THEN DISCUSSED THE AREA ISSUES WITH LOREN MAKUS. WE LOOKED AT THE SITE AND HAVE AGREED THAT THE PROBLEMS AT HAND ARE MINOR AND CAN BE ADDRESSED OUT IN THE FIELD AND PORTION OF THE PLAN ADJUSTED TO REFLECT THE CHANGES WITH "AS-BUILT DRAWINGS".
12/29/2009 NPPO - FINAL JLINVILLE Approved CITY APPROVED PLANS ARE REQUIRED TO BE ACCESSIBLE ON SITE FROM 8:00 AM- 5:00 PM FOR INSPECTION PURPOSES.
12/29/2009 LANDSCAPE - FINAL JLINVILLE Approved CITY APPROVED LANDSCAPE PLANS ARE REQUIRED TO BE ACCESSIBLE ON SITE FROM 8:00 AM- 5:00 PM FOR INSPECTION PURPOSES.
01/20/2010 TEP CLEARANCE - PM JWEATHER Approved ECO CLEARED FOR #A,B,C,D & HOUSE PANEL PER R. MORENO
02/04/2010 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :*
1) OK FOR FINAL
02/05/2010 ELECTRIC - FINAL RMORENO Approved IVRS - Inspection :*
1) ITEMS ON LIST ALL OK
02/05/2010 ELECTRIC - FINAL RMORENO Approved IVRS - Inspection :
See detailed listing on site.| 999*
1) OUTLET ON WALL NEXT TO FRONT DOOR ON UNIT B DOESN'T WORK AND SWITCH BY FRONT DOOR, OUTLET ON SECOND FLOOR TO
2) UNIT C SWITCH IN LIVING ROOM DOESN'T WORK
3) CHECK A & D FOR POWER AND LIGHTING
02/09/2010 FIRE SPKLR - FINAL CSCHULTZ Approved
02/10/2010 BUILDING - FINAL JBURGE Approved IVRS - Inspection :*
02/10/2010 U VALUE FOR WINDOW JBURGE Approved IVRS - Inspection :*
02/10/2010 FIRE - FINAL CSCHULTZ Approved
02/10/2010 PLUMBING - FINAL BBENEDON Approved IVRS - Inspection :*
02/11/2010 PERMIT FINALED JWEATHER Approved
02/11/2010 SIGN - FINAL JYBARRA Approved

Documents

File Name Document Type  
C OF O_02-16-2010.TIF CERT OF OCC VIEW
SITE PLAN_02-26-2009.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW