Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Apply Date:
06/03/2008
Applicant:
N/A
Description:
TI: RETAIL FOR HOLLISTER (Park Place Mall)
Contractors:
  • H R C: HEARTLAND RETAIL CONSTRUCTION

Permit Reviews

Permit Number - T08CM01820
Permit Status: C of o
Permit Description: TI: RETAIL FOR HOLLISTER (Park Place Mall)
Start Date Submittal Complete Date Status  
06/03/2008 PLANS OK TO SUBMIT - 3RD PARTY 06/03/2008 COMPLETED Review Details
06/03/2008 3RD PARTY REVIEW-COMMERCIAL TI 08/14/2008 COMPLETED Review Details
08/14/2008 POST 3RD PARTY REVIEW 10/15/2008 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T08CM01820
Permit Status: C of o
Permit Description: TI: RETAIL FOR HOLLISTER (Park Place Mall)
Total Outstanding Activity Conditions - 1
Date Name
06/03/2008 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T08CM01820
Permit Description: TI: RETAIL FOR HOLLISTER (Park Place Mall)
Total Completed Inspections - 24
Date Description Inspector Results Comments
11/14/2008 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
1. PROVIDE FRAMED OPENINGS AROUND ALL SIDES OF FIRE DAMPERS.
2. RELOCATE ACCESS DOORS CLOSER TO DAMPERS
3. PROVIDE DUCT SMOKE DETECTORS FOR SMOKE DAMPER SHUT DOWN AS PER NOTE #23
4. OK TO PROCEED WITH CEILING GRID.
11/18/2008 PLUMBING - ROUGH, SOIL RRICH Approved IVRS - Inspection :*
WATER TEST TO POINT OF EXISTING
1. MAKE REPAIR WITH RUN TEST AT POINT OF CONNECTION WITH INSPECTION FOR FALL
2. PROVIDE STAMPED SEALED LETTER FROM TIM PLEGER ENGINEER FOR 2" FLOOR DRAINS

REINSPECTION PIPING OK PIPE WRAPS & PRIMERS & FLOOR DRAINS OK

NEED NOTE #2 ONLY
11/26/2008 FRAMING JBURGE Approved IVRS - Inspection :*
1) LINES E.1 TO E.3, 2.1 TO X OK TO SHEETROCK PROGRESS AREAS
11/26/2008 ELECTRIC - PROGRESS RJIROUDE Approved IVRS - Inspection :*
12/04/2008 PLUMBING - ABOVE CEILING BBENEDON Approved IVRS - Inspection :*
12/05/2008 SHEET ROCK NAILING JBURGE Approved IVRS - Inspection :*
STOCKROOM B - WEST WALL; STOCKROOM A & RESTROOMS
OK TO TAPE PROGRESS AREAS
12/05/2008 BUILDING ABOVE CEILING JBURGE Approved IVRS - Inspection :*
T-GRID SYSTEM COMPLETE EXCEPT FOR STOCKROOM A
OK TO SET TILES IN PROGRESS AREAS
12/11/2008 ELECTRIC - INTERMEDIATE RJIROUDE Approved IVRS - Inspection :*
12/15/2008 PLUMBING - INTERMEDIATE RRICH Approved IVRS - Inspection :*
CLOSET FLANGE OK
PLEASE CALL IN ALL PLUMBING INSPECTIONS FOR APPROVAL
12/15/2008 PLUMBING - PROGRESS RRICH Approved IVRS - Inspection :*
12/31/2008 ELECTRIC - ABOVE CEILING RHOLLAND Approved IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
1) VDV CABELING TO BE SUPPORTED PER 725.24, 760.24, 800.24 & 300.11
2) SUPPORT WIRES NEEDED FOR EXIT LIGHTS, STRIP FLOURESCENTS
3) BOXES OVER FILLED
4) SUPPORT M/C CABLE 12" X 6' FT AND OFF OF GRID
5) FILL UNUSED OPENINGS IN BOX
6) CORDS NOT ALLOWED ABOVE CEILINGS 400.7 & 8
01/09/2009 BUILDING PRE-SLAB JBURGE Approved IVRS - Inspection :*
01/13/2009 FIRE SPKLR - FINAL LTHOMAS Approved
01/13/2009 FIRE - FINAL LTHOMAS Approved
01/15/2009 PLUMBING - FINAL RRICH Approved IVRS - Inspection :*
RECEIVED CHLORINE & BACTERIA REPORT
01/16/2009 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :*
01/16/2009 MECHANICAL - PROGRESS JMILITEL Approved
01/16/2009 MECHANICAL - ABOVE CEILING JMILITEL Approved
01/26/2009 ELECTRIC - FINAL RJIROUDE Approved
01/26/2009 BUILDING - PROGRESS JBURGE Approved
01/26/2009 BUILDING - FINAL JBURGE Approved IVRS - Inspection :*
01/27/2009 RIGHT OF WAY - FINAL MCASTRO Approved BY PHONE
01/27/2009 ENGINEERING - FINAL NKALAHAR Approved BY PHONE
01/28/2009 SIGN - FINAL HTHRALL Approved PERMITTED 3 WALL SIGNS