Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Apply Date:
06/03/2008
Applicant:
N/A
Description:
TI: RETAIL FOR HOLLISTER (Park Place Mall)
Contractors:
  • H R C: HEARTLAND RETAIL CONSTRUCTION

Permit Reviews

Permit Number - T08CM01820
Permit Status: C of o
Permit Description: TI: RETAIL FOR HOLLISTER (Park Place Mall)
Start Date Submittal Complete Date Status  
06/03/2008 PLANS OK TO SUBMIT - 3RD PARTY 06/03/2008 COMPLETED Review Details
06/03/2008 3RD PARTY REVIEW-COMMERCIAL TI 08/14/2008 COMPLETED Review Details
08/14/2008 POST 3RD PARTY REVIEW 10/15/2008 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T08CM01820
Permit Status: C of o
Permit Description: TI: RETAIL FOR HOLLISTER (Park Place Mall)
Total Outstanding Activity Conditions - 1
Date Name
06/03/2008 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T08CM01820
Permit Description: TI: RETAIL FOR HOLLISTER (Park Place Mall)
Total Completed Inspections - 24
Date Description Inspector Results Comments
11/14/2008 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
1. PROVIDE FRAMED OPENINGS AROUND ALL SIDES OF FIRE DAMPERS.
2. RELOCATE ACCESS DOORS CLOSER TO DAMPERS
3. PROVIDE DUCT SMOKE DETECTORS FOR SMOKE DAMPER SHUT DOWN AS PER NOTE #23
4. OK TO PROCEED WITH CEILING GRID.
11/18/2008 PLUMBING - ROUGH, SOIL RRICH Approved IVRS - Inspection :*
WATER TEST TO POINT OF EXISTING
1. MAKE REPAIR WITH RUN TEST AT POINT OF CONNECTION WITH INSPECTION FOR FALL
2. PROVIDE STAMPED SEALED LETTER FROM TIM PLEGER ENGINEER FOR 2" FLOOR DRAINS

REINSPECTION PIPING OK PIPE WRAPS & PRIMERS & FLOOR DRAINS OK

NEED NOTE #2 ONLY
11/26/2008 FRAMING JBURGE Approved IVRS - Inspection :*
1) LINES E.1 TO E.3, 2.1 TO X OK TO SHEETROCK PROGRESS AREAS
11/26/2008 ELECTRIC - PROGRESS RJIROUDE Approved IVRS - Inspection :*
12/04/2008 PLUMBING - ABOVE CEILING BBENEDON Approved IVRS - Inspection :*
12/05/2008 SHEET ROCK NAILING JBURGE Approved IVRS - Inspection :*
STOCKROOM B - WEST WALL; STOCKROOM A & RESTROOMS
OK TO TAPE PROGRESS AREAS
12/05/2008 BUILDING ABOVE CEILING JBURGE Approved IVRS - Inspection :*
T-GRID SYSTEM COMPLETE EXCEPT FOR STOCKROOM A
OK TO SET TILES IN PROGRESS AREAS
12/11/2008 ELECTRIC - INTERMEDIATE RJIROUDE Approved IVRS - Inspection :*
12/15/2008 PLUMBING - INTERMEDIATE RRICH Approved IVRS - Inspection :*
CLOSET FLANGE OK
PLEASE CALL IN ALL PLUMBING INSPECTIONS FOR APPROVAL
12/15/2008 PLUMBING - PROGRESS RRICH Approved IVRS - Inspection :*
12/31/2008 ELECTRIC - ABOVE CEILING RHOLLAND Approved IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
1) VDV CABELING TO BE SUPPORTED PER 725.24, 760.24, 800.24 & 300.11
2) SUPPORT WIRES NEEDED FOR EXIT LIGHTS, STRIP FLOURESCENTS
3) BOXES OVER FILLED
4) SUPPORT M/C CABLE 12" X 6' FT AND OFF OF GRID
5) FILL UNUSED OPENINGS IN BOX
6) CORDS NOT ALLOWED ABOVE CEILINGS 400.7 & 8
01/09/2009 BUILDING PRE-SLAB JBURGE Approved IVRS - Inspection :*
01/13/2009 FIRE SPKLR - FINAL LTHOMAS Approved
01/13/2009 FIRE - FINAL LTHOMAS Approved
01/15/2009 PLUMBING - FINAL RRICH Approved IVRS - Inspection :*
RECEIVED CHLORINE & BACTERIA REPORT
01/16/2009 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :*
01/16/2009 MECHANICAL - PROGRESS JMILITEL Approved
01/16/2009 MECHANICAL - ABOVE CEILING JMILITEL Approved
01/26/2009 ELECTRIC - FINAL RJIROUDE Approved
01/26/2009 BUILDING - PROGRESS JBURGE Approved
01/26/2009 BUILDING - FINAL JBURGE Approved IVRS - Inspection :*
01/27/2009 RIGHT OF WAY - FINAL MCASTRO Approved BY PHONE
01/27/2009 ENGINEERING - FINAL NKALAHAR Approved BY PHONE
01/28/2009 SIGN - FINAL HTHRALL Approved PERMITTED 3 WALL SIGNS

Documents

File Name Document Type  
C OF O_01-28-2009.TIF CERT OF OCC VIEW
001__TITLE.TIF CONSTRPLANS VIEW
002__A0.1.TIF CONSTRPLANS VIEW
003__A0.2.TIF CONSTRPLANS VIEW
004__A0.3.TIF CONSTRPLANS VIEW
005__A0.4.TIF CONSTRPLANS VIEW
006__A0.5.TIF CONSTRPLANS VIEW
007__A1.1.TIF CONSTRPLANS VIEW
008__A1.2.TIF CONSTRPLANS VIEW
009__A1.2A.TIF CONSTRPLANS VIEW
010__A2.1.TIF CONSTRPLANS VIEW
011__A3.1.TIF CONSTRPLANS VIEW
012__A4.1.TIF CONSTRPLANS VIEW
013__A7.1.TIF CONSTRPLANS VIEW
014__A7.2.TIF CONSTRPLANS VIEW
015__A8.1.TIF CONSTRPLANS VIEW
016__A8.1A.TIF CONSTRPLANS VIEW
017__A8.2.TIF CONSTRPLANS VIEW
018__A8.3.TIF CONSTRPLANS VIEW
019__A8.4.TIF CONSTRPLANS VIEW
020__A8.4A.TIF CONSTRPLANS VIEW
021__A8.4B.TIF CONSTRPLANS VIEW
022__A8.4C.TIF CONSTRPLANS VIEW
023__A8.5.TIF CONSTRPLANS VIEW
024__A8.6.TIF CONSTRPLANS VIEW
025__A10.1.TIF CONSTRPLANS VIEW
026__A10.2.TIF CONSTRPLANS VIEW
027__A10.3.TIF CONSTRPLANS VIEW
028__A10.4.TIF CONSTRPLANS VIEW
029__A11.1.TIF CONSTRPLANS VIEW
030__A12.1.TIF CONSTRPLANS VIEW
031__A12.2.TIF CONSTRPLANS VIEW
032__A12.3.TIF CONSTRPLANS VIEW
033__A12.4.TIF CONSTRPLANS VIEW
034__A12.5.TIF CONSTRPLANS VIEW
035__A12.6.TIF CONSTRPLANS VIEW
036__A12.7.TIF CONSTRPLANS VIEW
037__E1.1.TIF CONSTRPLANS VIEW
038__E2.1.TIF CONSTRPLANS VIEW
039__E3.1.TIF CONSTRPLANS VIEW
040__E3.2.TIF CONSTRPLANS VIEW
041__E3.5.TIF CONSTRPLANS VIEW
042__E4.1.TIF CONSTRPLANS VIEW
043__E4.2.TIF CONSTRPLANS VIEW
044__E5.1.TIF CONSTRPLANS VIEW
045__FP1.1.TIF CONSTRPLANS VIEW
046__M1.1.TIF CONSTRPLANS VIEW
047__M2.1.TIF CONSTRPLANS VIEW
048__M3.1.TIF CONSTRPLANS VIEW
049__M4.1.TIF CONSTRPLANS VIEW
050__M5.1.TIF CONSTRPLANS VIEW
051__M6.1.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW