Permit: T08CM00726
Permit Details
Apply Date:
03/04/2008
Applicant:
SHANA GARRETT
Description:
REPLACE:GENERATOR & ADD GENERATOR ROOM
Contractors:
- ENVIRONMENTAL STRUCTURES INC
Permit Reviews
Permit Number - T08CM00726
Permit Status: Final
Permit Description: REPLACE:GENERATOR & ADD GENERATOR ROOM
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/04/2008 | PLANS OK TO SUBMIT - COMM | 03/04/2008 | COMPLETED |
| 03/04/2008 | COMMERCIAL-BLDG/FIRE/ZONING/ENG | 03/20/2008 | COMPLETED |
| 03/20/2008 | RESUBMITTAL | 04/09/2008 | COMPLETED |
| 04/09/2008 | RESUBMITTAL | 04/18/2008 | COMPLETED |
| 09/30/2008 | REVISION - - 1ST | 10/01/2008 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T08CM00726
Permit Status: Final
Permit Description: REPLACE:GENERATOR & ADD GENERATOR ROOM
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 03/04/2008 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T08CM00726
Permit Description: REPLACE:GENERATOR & ADD GENERATOR ROOM
Total Completed Inspections - 13
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/23/2008 | EXCAVATION/LAYOUT REBAR & ZON | JBURGE | Approved | IVRS - Inspection :* DO NOT POUR UNTIL GROUNDING SYSTEM IS ELECTRICALLY APPROVED |
| 05/16/2008 | REINFORCED MASONRY PRE-GROUT | JBURGE | Approved | MASONRY WALLS WERE CHANGED TO METAL STUDS AND SHEETROCK AS PER RFI # SK-001.1 (04/24/08) STANTEC FRAMING AS PER RFI- OK TO SHEETROCK AREAN AND TAPE WALLS |
| 06/26/2008 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection :* 1. PRESSURE TEST OK 2. CONNECTIONS OK |
| 06/26/2008 | PLUMBING - GAS PRESSURE TEST | RMYERS | Approved | IVRS - Inspection :* |
| 08/08/2008 | MECHANICAL - FINAL | MRAMBER | Approved | IVRS - Inspection :* |
| 08/08/2008 | MECHANICAL - INTERMEDIATE | MRAMBER | Approved | IVRS - Inspection :* |
| 08/15/2008 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection :* OK FOR GAS |
| 10/03/2008 | ELECTRIC - FINAL | RHOLLAND | Approved | IVRS - Inspection :* 1. ELEVATOR EM POWER DISCONNECT LINE & LOAD REVERSED PER DISCONNECT MARKINGS 2. NEED LISTING & LABELING OF GENERATOR AS PER CODE AND PLANS RECEIVED PAPERWORK -- TESTING ENGINEER |
| 09/25/2009 | BUILDING - FINAL | LHANLY | Approved | |
| 09/25/2009 | BUILDING ABOVE CEILING | LHANLY | Approved | |
| 09/25/2009 | ELECTRIC - INTERMEDIATE | LHANLY | Approved | |
| 09/25/2009 | ELECTRIC - UNDERGROUND | LHANLY | Approved | |
| 09/25/2009 | ELECTRIC - ABOVE CEILING | LHANLY | Approved |