Permit: T07CM03289
Permit Details
Apply Date:
08/07/2007
Applicant:
GEORGE HOLGUIN
Description:
TI:LUCKY WISHBONE
Architects:
- A D C
Contractors:
- OLLER BUILDERS L L C
Permit Reviews
Permit Number - T07CM03289
Permit Status: C of o
Permit Description: TI:LUCKY WISHBONE
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
04/15/2008 | 3RD PARTY REVIEW-REVISION/OTHER | 04/24/2008 | COMPLETED |
08/07/2007 | PLANS OK TO SUBMIT - 3RD PARTY | 08/08/2007 | COMPLETED |
08/08/2007 | 3RD PARTY REVIEW-COMMERCIAL TI | 09/13/2007 | COMPLETED |
09/13/2007 | POST 3RD PARTY REVIEW | 09/13/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T07CM03289
Permit Status: C of o
Permit Description: TI:LUCKY WISHBONE
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
08/07/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T07CM03289
Permit Description: TI:LUCKY WISHBONE
Total Completed Inspections - 31
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/05/2007 | PLUMBING - PRE SLAB | RMYERS | Approved | IVRS - Inspection :* 1. UNDERGROUND INSTALLED PER REDLINE WATER TEST OK 2. OK TO COVER |
11/07/2007 | BUILDING PRE-SLAB | AQUIROZ | Approved | IVRS - Inspection :* |
11/21/2007 | ELECTRIC - ABOVE CEILING | CCLEMENS | Approved | IVRS - Inspection :* |
12/04/2007 | ELECTRIC - INTERMEDIATE | CCLEMENS | Approved | IVRS - Inspection :* 1. NEED TO PROVIDE SEALED DRAWING FROM ENGINEER CONCERNING INTERLOCK WIRING FOR TYPE ONE HOOD CHECK WITH T.F.D FOR REQUIREMENTS BEFORE THIS DRAWING IS MADE 2. OK WALL COVER PREP AREA/ENTRY NEED REVISION LETTER FROM ENGINEER FOR WIRING NOT PER PLAN |
12/05/2007 | FIRE - KITCHEN EXH HOOD FINAL | LLAKEY | Approved | |
12/07/2007 | PLUMBING - ABOVE CEILING | RMYERS | Approved | |
12/10/2007 | SHEET ROCK NAILING | AQUIROZ | Approved | IVRS - Inspection :* |
12/10/2007 | FRAMING | AQUIROZ | Approved | IVRS - Inspection :* |
12/21/2007 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection :* |
12/21/2007 | PLUMBING - GAS PRESSURE TEST | RMYERS | Approved | IVRS - Inspection :* |
02/26/2008 | RIGHT OF WAY - FINAL | MOTERO | Approved | |
02/28/2008 | NPPO - FINAL | PMCLAUGH | Approved | |
02/28/2008 | LANDSCAPE - FINAL | PMCLAUGH | Approved | |
02/28/2008 | ROOF NAILING | AQUIROZ | Approved | IVRS - Inspection :* |
03/03/2008 | MECHANICAL - HOODS | MRAMBER | Approved | IVRS - Inspection :* |
03/03/2008 | MECHANICAL - INTERMEDIATE | MRAMBER | Approved | IVRS - Inspection :* |
03/04/2008 | PLUMBING - GAS PRESS TEST FNL | RMYERS | Approved | IVRS - Inspection :* |
03/11/2008 | MECHANICAL - ABOVE CEILING | MRAMBER | Approved | IVRS - Inspection :* REFER TO DETAIL M-2 101 FOR HANGER APPLICATION IN REGRESS TO FLEX DUCT SPECIFICALLY 24 GA. STRAPS AND 12" SADDLES |
03/19/2008 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection :* |
03/21/2008 | BUILDING ABOVE CEILING | AQUIROZ | Approved | IVRS - Inspection :* |
04/10/2008 | MECHANICAL - FINAL | MRAMBER | Approved | IVRS - Inspection :* |
04/10/2008 | MECHANICAL - HOOD SYSTEMS | MRAMBER | Approved | IVRS - Inspection :* |
04/10/2008 | ELECTRIC - FINAL | CCLEMENS | Approved | IVRS - Inspection :* |
04/10/2008 | ELECTRIC - RECONNECT | CCLEMENS | Approved | IVRS - Inspection :* |
04/10/2008 | ELECTRIC - CONSTRUCTION POWER | CCLEMENS | Approved | IVRS - Inspection :* |
04/21/2008 | BUILDING - FINAL | AQUIROZ | Approved | IVRS - Inspection :* |
04/21/2008 | FIRE SPKLR - FINAL | LLAKEY | Approved | |
04/21/2008 | FIRE - FINAL | LLAKEY | Approved | |
04/21/2008 | SIGN - FINAL | JSONKIN | Approved | |
04/22/2008 | ENGINEERING - FINAL | MRUSSO | Approved | |
04/28/2008 | HEALTH DEPT - FINAL 724-7908 | MRAMIREZ | Approved |